2008-07-14 09:15:55 +12:00
|
|
|
|
<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN">
|
|
|
|
|
<HTML>
|
|
|
|
|
<HEAD>
|
|
|
|
|
<META HTTP-EQUIV="CONTENT-TYPE" CONTENT="text/html; charset=utf-8">
|
|
|
|
|
<TITLE>One-Dimensional Symbols</TITLE>
|
2008-09-03 08:27:56 +12:00
|
|
|
|
<META NAME="GENERATOR" CONTENT="OpenOffice.org 2.4 (Unix)">
|
2008-07-14 09:15:55 +12:00
|
|
|
|
<META NAME="CREATED" CONTENT="20070730;21081900">
|
2008-10-19 21:57:58 +13:00
|
|
|
|
<META NAME="CHANGED" CONTENT="20081019;9043400">
|
2008-07-14 09:15:55 +12:00
|
|
|
|
<STYLE TYPE="text/css">
|
|
|
|
|
<!--
|
|
|
|
|
TD P { color: #000000 }
|
|
|
|
|
H1 { color: #000000 }
|
|
|
|
|
P { color: #000000 }
|
|
|
|
|
TH P { color: #000000 }
|
|
|
|
|
A:link { color: #0000ff }
|
|
|
|
|
A:visited { color: #840084 }
|
|
|
|
|
-->
|
|
|
|
|
</STYLE>
|
|
|
|
|
</HEAD>
|
|
|
|
|
<BODY LANG="en-GB" TEXT="#000000" LINK="#0000ff" VLINK="#840084" BGCOLOR="#ffffff" DIR="LTR">
|
|
|
|
|
<TABLE WIDTH=100% BORDER=0 CELLPADDING=0 CELLSPACING=0 STYLE="page-break-before: always">
|
|
|
|
|
<TR>
|
|
|
|
|
<TH COLSPAN=3>
|
|
|
|
|
<P ALIGN=CENTER>Zint Barcode Generator</P>
|
|
|
|
|
</TH>
|
|
|
|
|
</TR>
|
|
|
|
|
<TR VALIGN=BOTTOM>
|
|
|
|
|
<TD WIDTH=10%>
|
|
|
|
|
<P ALIGN=LEFT><A HREF="symbologies.html">Prev</A></P>
|
|
|
|
|
</TD>
|
|
|
|
|
<TD WIDTH=80%></TD>
|
|
|
|
|
<TD WIDTH=10%>
|
|
|
|
|
<P ALIGN=RIGHT><A HREF="stacked.html">Next</A></P>
|
|
|
|
|
</TD>
|
|
|
|
|
</TR>
|
|
|
|
|
</TABLE>
|
|
|
|
|
<HR>
|
|
|
|
|
<H1>5.1 One-Dimensional Symbols</H1>
|
|
|
|
|
<P>One-Dimensional Symbols are what most people associate with the
|
|
|
|
|
term <I>barcode</I>. They consist of a number of bars and a number of
|
|
|
|
|
spaces of differing widths.</P>
|
|
|
|
|
<P><BR><BR>
|
|
|
|
|
</P>
|
|
|
|
|
<P><A NAME="CODE11"></A><FONT SIZE=5><B>5.1.1 Code 11</B></FONT></P>
|
|
|
|
|
<P>Developed by Intermec in 1977, Code 11 is similar to Code 2 of 5
|
|
|
|
|
Matrix and is primarily used in telecommunications. The symbol can
|
|
|
|
|
encode any length string consisting of the digits 0-9 and the dash
|
|
|
|
|
character (-). One modulo-11 check digit is calculated.</P>
|
2008-09-03 08:27:56 +12:00
|
|
|
|
<P ALIGN=CENTER><IMG SRC="code11.png" NAME="graphics1" ALIGN=LEFT WIDTH=190 HEIGHT=118 BORDER=0><BR CLEAR=LEFT><BR><BR>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
</P>
|
|
|
|
|
<P><A NAME="CODE25"></A><FONT SIZE=5><B>5.1.2 Code 2 of 5</B></FONT></P>
|
|
|
|
|
<P>Code 2 of 5 is a family of one-dimensional symbols, 8 of which are
|
|
|
|
|
supported by Zint.</P>
|
|
|
|
|
<P><A NAME="CODE25STAND"></A><FONT SIZE=4><B>5.1.2.1 Standard Code 2
|
|
|
|
|
of 5</B></FONT></P>
|
|
|
|
|
<P>Also known as Code 2 of 5 Matrix is a self-checking code used in
|
|
|
|
|
industrial applications and photo development. Standard Code 2 of 5
|
|
|
|
|
will encode any length numeric input (digits 0-9).</P>
|
|
|
|
|
<P><A NAME="IATA"></A><FONT SIZE=4><B>5.1.2.2 IATA Code 2 of 5</B></FONT></P>
|
|
|
|
|
<P>Used for baggage handling in the air-transport industry by the
|
|
|
|
|
International Air Transport Agency, this self-checking code will
|
|
|
|
|
encode any length numeric input (digits 0-9) and does not include a
|
|
|
|
|
check digit.</P>
|
|
|
|
|
<P><A NAME="IND25"></A><FONT SIZE=4><B>5.1.2.3 Industrial Code 2 of 5</B></FONT></P>
|
|
|
|
|
<P>Industrial Code 2 of 5 can encode any length numeric input (digits
|
|
|
|
|
0-9) and does not include a check digit.</P>
|
|
|
|
|
<P><A NAME="INTER25"></A><FONT SIZE=4><B>5.1.2.4 Interleaved Code 2
|
|
|
|
|
of 5</B></FONT></P>
|
|
|
|
|
<P>This self-checking symbology encodes pairs of numbers, and so can
|
|
|
|
|
only encode an even number of digits (0-9). If an odd number of
|
|
|
|
|
digits is entered a leading zero is added by Zint. No check digit is
|
|
|
|
|
added.</P>
|
|
|
|
|
<P><A NAME="DLOGIC"></A><FONT SIZE=4><B>5.1.2.5 Code 2 of 5 Data
|
|
|
|
|
Logic</B></FONT></P>
|
|
|
|
|
<P>Data Logic is a proprietary variation of Standard Code 2 of 5.
|
|
|
|
|
Data Logic does not include a check digit and can encode any length
|
|
|
|
|
numeric input (digits 0-9).</P>
|
|
|
|
|
<P><A NAME="ITF14"></A><FONT SIZE=4><B>5.1.2.6 ITF-14</B></FONT></P>
|
|
|
|
|
<P>ITF-14, also known as UPC Shipping Container Symbol, Case Code and
|
|
|
|
|
EAN-14, is based on Interleaved Code 2 of 5 and requires a 13 digit
|
|
|
|
|
numeric input (digits 0-9). One modulo-10 check digit is calculated.</P>
|
2008-09-20 18:10:34 +12:00
|
|
|
|
<P><A NAME="DPLEIT"></A><FONT SIZE=4><B>5.1.2.7 Deutsche Post
|
|
|
|
|
Leitcode</B></FONT></P>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
<P>Leitcode is based on Interleaved Code 2 of 5 and is used by
|
2008-09-03 08:27:56 +12:00
|
|
|
|
Deutsche Post for mailing purposes. Leitcode requires a 13-digit
|
2008-07-14 09:15:55 +12:00
|
|
|
|
numerical input and includes a check digit.</P>
|
2008-09-03 08:27:56 +12:00
|
|
|
|
<P><A NAME="DPIDENT"></A><FONT SIZE=4><B>5.1.2.8 Deutsche Post
|
2008-07-14 09:15:55 +12:00
|
|
|
|
Identcode</B></FONT></P>
|
|
|
|
|
<P>Identcode is based on Interleaved Code 2 of 5 and is used by
|
2008-09-03 08:27:56 +12:00
|
|
|
|
Deutsche Post for mailing purposes. Identcode requires an 11-digit
|
2008-07-14 09:15:55 +12:00
|
|
|
|
numerical input and includes a check digit.</P>
|
2008-09-03 08:27:56 +12:00
|
|
|
|
<P ALIGN=CENTER><IMG SRC="itf14.png" NAME="graphics2" ALIGN=LEFT WIDTH=382 HEIGHT=150 BORDER=0><BR CLEAR=LEFT><BR><BR>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
</P>
|
|
|
|
|
<P><A NAME="UPC"></A><FONT SIZE=5><B>5.1.3 Universal Product Code (EN
|
|
|
|
|
797)</B></FONT></P>
|
|
|
|
|
<P><A NAME="UPCA"></A><FONT SIZE=4><B>5.1.3.1 UPC Version A</B></FONT></P>
|
|
|
|
|
<P>UPC-A is used in the United States for retail applications. The
|
|
|
|
|
symbol requires an 11 digit article number. The check digit is
|
|
|
|
|
calculated by Zint. In addition EAN-2 and EAN-5 add-on symbols can be
|
|
|
|
|
added using the + character. For example, to draw a UPC-A symbol with
|
|
|
|
|
the data 72527270270 with an EAN-5 add-on showing the data 12345 use
|
|
|
|
|
the command:</P>
|
|
|
|
|
<P><FONT FACE="Courier, monospace"><FONT SIZE=2>zint --barcode=34 -d
|
|
|
|
|
72527270270+12345</FONT></FONT></P>
|
|
|
|
|
<P>or encode a data string with the + character included:
|
|
|
|
|
</P>
|
|
|
|
|
<P><FONT FACE="Courier, monospace"><FONT SIZE=2>my_symbol->symbology
|
|
|
|
|
= BARCODE_UPCA;<BR>error = ZBarcode_Encode_and_Print(my_symbol,
|
|
|
|
|
"72527270270+12345");</FONT></FONT></P>
|
|
|
|
|
<P><A NAME="UPCE"></A><FONT SIZE=4><B>5.1.3.2 UPC Version E</B></FONT></P>
|
|
|
|
|
<P>UPC-E is a zero-compressed version of UPC-A developed for smaller
|
|
|
|
|
packages. The code requires a 6 digit article number (digits 0-9).
|
|
|
|
|
The check digit is calculated by Zint. EAN-2 and EAN-5 add-on symbols
|
|
|
|
|
can be added using the + character as with UPC-A. In addition Zint
|
|
|
|
|
also supports Number System 1 encoding by entering a 7-digit article
|
|
|
|
|
number stating with the digit 1. For example:</P>
|
|
|
|
|
<P><FONT FACE="Courier, monospace"><FONT SIZE=2>zint --barcode=37 -d
|
|
|
|
|
1123456</FONT></FONT></P>
|
|
|
|
|
<P>or</P>
|
|
|
|
|
<P><FONT FACE="Courier, monospace"><FONT SIZE=2>my_symbol->symbology
|
|
|
|
|
= BARCODE_UPCE;<BR>error = ZBarcode_Encode_and_Print(my_symbol,
|
|
|
|
|
"1123456");</FONT></FONT></P>
|
2008-09-03 08:27:56 +12:00
|
|
|
|
<P><IMG SRC="upca.png" NAME="graphics3" ALIGN=LEFT WIDTH=288 HEIGHT=118 BORDER=0><BR CLEAR=LEFT><BR><BR>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
</P>
|
|
|
|
|
<P><A NAME="EAN"></A><FONT SIZE=5><B>5.1.4 European Article Number
|
|
|
|
|
(EN 797)</B></FONT></P>
|
|
|
|
|
<P><A NAME="EANX"></A><FONT SIZE=4><B>5.1.5.1 EAN-2, EAN-5, EAN-8 and
|
|
|
|
|
EAN-13</B></FONT></P>
|
|
|
|
|
<P>The EAN system is used in retail across Europe and includes
|
|
|
|
|
standards for EAN-2 and EAN-5 add-on codes, EAN-8 and EAN-13 which
|
|
|
|
|
encode 2, 5, 7 or 12 digit numbers respectively. Zint will decide
|
|
|
|
|
which symbology to use depending on the length of the input data. In
|
|
|
|
|
addition EAN-2 and EAN-5 add-on symbols can be added using the +
|
|
|
|
|
symbol as with UPC symbols. For example</P>
|
|
|
|
|
<P><FONT FACE="Courier, monospace"><FONT SIZE=2>zint --barcode=13 -d
|
|
|
|
|
54321</FONT></FONT></P>
|
|
|
|
|
<P>will encode a stand-alone EAN-5, whereas</P>
|
|
|
|
|
<P><FONT FACE="Courier, monospace"><FONT SIZE=2>zint --barcode=13 -d
|
|
|
|
|
7432365+54321</FONT></FONT></P>
|
|
|
|
|
<P>will encode an EAN-8 symbol with an EAN-5 add-on. As before these
|
|
|
|
|
results can be achieved using the API:</P>
|
|
|
|
|
<P><FONT FACE="Courier, monospace"><FONT SIZE=2>my_symbol->symbology
|
|
|
|
|
= BARCODE_EANX<BR>error = ZBarcode_Encode_and_Print(my_symbol,
|
|
|
|
|
"54321");<BR>error = ZBarcode_Encode_and_Print(my_symbol,
|
|
|
|
|
"7432365+54321");</FONT></FONT></P>
|
|
|
|
|
<P>All of the EAN symbols include check data which is added by Zint.</P>
|
|
|
|
|
<P><A NAME="ISBN"></A><FONT SIZE=4><B>5.1.4.2 SBN, ISBN and ISBN-13</B></FONT></P>
|
|
|
|
|
<P>EAN-13 symbols (also known as Bookland EAN-13) can also be
|
|
|
|
|
produced from 9-digit SBN, 10-digit ISBN or 13-digit ISBN-13 data.
|
|
|
|
|
The relevant check digit needs to be present in the input data and
|
|
|
|
|
will be verified before the symbol is generated. In addition EAN-2
|
|
|
|
|
and EAN-5 add-on symbols can be added using the + symbol as with UPC
|
|
|
|
|
symbols.</P>
|
2008-09-03 08:27:56 +12:00
|
|
|
|
<P><IMG SRC="ean13.png" NAME="graphics4" ALIGN=LEFT WIDTH=288 HEIGHT=118 BORDER=0><BR CLEAR=LEFT><BR><BR>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
</P>
|
|
|
|
|
<P><A NAME="PLESSEY"></A><FONT SIZE=5><B>5.1.5 Plessey</B></FONT></P>
|
|
|
|
|
<P>Also known as Plessey Code, this symbology was developed by the
|
|
|
|
|
Plessey Company Ltd. in the UK. The symbol can encode any length data
|
|
|
|
|
consisting of digits (0-9) or letters A-F and includes a CRC check
|
|
|
|
|
digit.</P>
|
2008-09-03 08:27:56 +12:00
|
|
|
|
<P ALIGN=CENTER><IMG SRC="plessey.png" NAME="graphics5" ALIGN=LEFT WIDTH=390 HEIGHT=118 BORDER=0><BR CLEAR=LEFT><BR><BR>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
</P>
|
|
|
|
|
<P><A NAME="MSI"></A><FONT SIZE=5><B>5.1.6 MSI Plessey</B></FONT></P>
|
|
|
|
|
<P>Based on Plessey and developed by MSE Data Corporation, MSI
|
2008-09-20 18:10:34 +12:00
|
|
|
|
Plessey is available with a range of check digit options available by
|
|
|
|
|
setting <FONT FACE="Courier, monospace">option_2</FONT> or by using
|
2008-10-19 21:57:58 +13:00
|
|
|
|
the –<FONT FACE="Courier, monospace">ver=</FONT> switch. Any length
|
2008-07-14 09:15:55 +12:00
|
|
|
|
numeric (digits 0-9) input can be encoded. The table below shows the
|
|
|
|
|
options available:</P>
|
|
|
|
|
<CENTER>
|
|
|
|
|
<TABLE WIDTH=817 BORDER=1 CELLPADDING=4 CELLSPACING=3>
|
2008-09-20 18:10:34 +12:00
|
|
|
|
<COL WIDTH=276>
|
|
|
|
|
<COL WIDTH=514>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
<THEAD>
|
|
|
|
|
<TR VALIGN=TOP>
|
2008-09-20 18:10:34 +12:00
|
|
|
|
<TH WIDTH=276>
|
|
|
|
|
<P>Value of <FONT FACE="Courier, monospace">option_2</FONT></P>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
</TH>
|
2008-09-20 18:10:34 +12:00
|
|
|
|
<TH WIDTH=514>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
<P>Check Digits</P>
|
|
|
|
|
</TH>
|
|
|
|
|
</TR>
|
|
|
|
|
</THEAD>
|
|
|
|
|
<TBODY>
|
|
|
|
|
<TR VALIGN=TOP>
|
2008-09-20 18:10:34 +12:00
|
|
|
|
<TD WIDTH=276>
|
|
|
|
|
<P ALIGN=CENTER>0</P>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
</TD>
|
2008-09-20 18:10:34 +12:00
|
|
|
|
<TD WIDTH=514>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
<P ALIGN=CENTER>None</P>
|
|
|
|
|
</TD>
|
|
|
|
|
</TR>
|
|
|
|
|
<TR VALIGN=TOP>
|
2008-09-20 18:10:34 +12:00
|
|
|
|
<TD WIDTH=276>
|
|
|
|
|
<P ALIGN=CENTER>1</P>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
</TD>
|
2008-09-20 18:10:34 +12:00
|
|
|
|
<TD WIDTH=514>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
<P ALIGN=CENTER>Modulo-10</P>
|
|
|
|
|
</TD>
|
|
|
|
|
</TR>
|
|
|
|
|
<TR VALIGN=TOP>
|
2008-09-20 18:10:34 +12:00
|
|
|
|
<TD WIDTH=276>
|
|
|
|
|
<P ALIGN=CENTER>2</P>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
</TD>
|
2008-09-20 18:10:34 +12:00
|
|
|
|
<TD WIDTH=514>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
<P ALIGN=CENTER>Modulo-10 & Modulo-10</P>
|
|
|
|
|
</TD>
|
|
|
|
|
</TR>
|
|
|
|
|
<TR VALIGN=TOP>
|
2008-09-20 18:10:34 +12:00
|
|
|
|
<TD WIDTH=276>
|
|
|
|
|
<P ALIGN=CENTER>3</P>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
</TD>
|
2008-09-20 18:10:34 +12:00
|
|
|
|
<TD WIDTH=514>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
<P ALIGN=CENTER>Modulo-11</P>
|
|
|
|
|
</TD>
|
|
|
|
|
</TR>
|
|
|
|
|
<TR VALIGN=TOP>
|
2008-09-20 18:10:34 +12:00
|
|
|
|
<TD WIDTH=276>
|
|
|
|
|
<P ALIGN=CENTER>4</P>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
</TD>
|
2008-09-20 18:10:34 +12:00
|
|
|
|
<TD WIDTH=514>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
<P ALIGN=CENTER>Modulo-11 & Modulo-10</P>
|
|
|
|
|
</TD>
|
|
|
|
|
</TR>
|
|
|
|
|
</TBODY>
|
|
|
|
|
</TABLE>
|
|
|
|
|
</CENTER>
|
|
|
|
|
<P><BR><BR>
|
|
|
|
|
</P>
|
2008-09-03 08:27:56 +12:00
|
|
|
|
<P ALIGN=CENTER><IMG SRC="msi.png" NAME="graphics6" ALIGN=LEFT WIDTH=230 HEIGHT=118 BORDER=0><BR CLEAR=LEFT><BR><BR>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
</P>
|
|
|
|
|
<P><A NAME="TELEPEN"></A><FONT SIZE=5><B>5.1.7 Telepen</B></FONT></P>
|
|
|
|
|
<P><A NAME="TELEPENASCII"></A><FONT SIZE=4><B>5.1.7.1 Telepen Alpha</B></FONT></P>
|
|
|
|
|
<P>Telepen Alpha was developed by SB Electronic Systems Limited and
|
|
|
|
|
can encode any length of ASCII text input. Telepen includes a
|
|
|
|
|
modulo-127 check digit.</P>
|
|
|
|
|
<P><A NAME="TELENUM"></A><FONT SIZE=4><B>5.1.7.2 Telepen Numeric</B></FONT></P>
|
2008-09-20 18:10:34 +12:00
|
|
|
|
<P>Telepen Numeric allows compression of numeric data into a Telepen
|
|
|
|
|
symbol. Data can consist of pairs of numbers or pairs consisting of a
|
|
|
|
|
numerical digit followed an X character. For example: 466333 and
|
|
|
|
|
466X33 are valid codes whereas 46X333 is not (the digit pair “X3”
|
|
|
|
|
is not valid). Includes a modulo-127 check digit.</P>
|
2008-09-03 08:27:56 +12:00
|
|
|
|
<P ALIGN=CENTER><IMG SRC="telepen.png" NAME="graphics7" ALIGN=LEFT WIDTH=320 HEIGHT=118 BORDER=0><BR CLEAR=LEFT><BR><BR>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
</P>
|
|
|
|
|
<P><A NAME="CODE39"></A><FONT SIZE=5><B>5.1.8 Code 39</B></FONT></P>
|
|
|
|
|
<P><A NAME="CODE39STAND"></A><FONT SIZE=4><B>5.1.8.1 Standard Code 39
|
|
|
|
|
(ISO 16388)</B></FONT></P>
|
|
|
|
|
<P>Standard Code 39 was developed in 1974 by Intermec. Input data can
|
|
|
|
|
be of any length and supports the characters 0-9, A-Z, dash (-), full
|
|
|
|
|
stop (.), space, asterisk (*), dollar ($), slash (/), plus (+) and
|
|
|
|
|
percent (%). The original standard (symbology 8) does not require a
|
2008-09-20 18:10:34 +12:00
|
|
|
|
check digit but a modulo-43 check digit can be added if required by
|
|
|
|
|
setting <FONT FACE="Courier, monospace">option_2 = 1</FONT> or using
|
|
|
|
|
<FONT FACE="Courier, monospace">--ver=1.</FONT></P>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
<P><A NAME="EXCODE39"></A><FONT SIZE=4><B>5.1.8.2 Extended Code 39</B></FONT></P>
|
|
|
|
|
<P>Also known as Code 39e and Code39+, this symbology expands on
|
|
|
|
|
Standard Code 39 to provide support to the full ASCII character set.
|
|
|
|
|
The original standard (symbology 9) does not require a check digit
|
2008-09-20 18:10:34 +12:00
|
|
|
|
but a modulo-43 check digit can be added if required by setting
|
|
|
|
|
<FONT FACE="Courier, monospace">option_2 = 1</FONT> or using <FONT FACE="Courier, monospace">--ver=1.</FONT></P>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
<P><A NAME="CODE93"></A><FONT SIZE=4><B>5.1.8.3 Code 93</B></FONT></P>
|
|
|
|
|
<P>A variation of Extended Code 39, Code 93 also supports full ASCII
|
|
|
|
|
text. Two check digits are added.</P>
|
|
|
|
|
<P><A NAME="PZN"></A><FONT SIZE=4><B>5.1.8.4 PZN</B></FONT></P>
|
|
|
|
|
<P>PZN is a Code 39 based symbology used by the pharmaceutical
|
|
|
|
|
industry in Germany. PZN encodes a 6 digit number and includes a
|
|
|
|
|
modulo-10 check digit.</P>
|
|
|
|
|
<P><A NAME="LOGMARS"></A><FONT SIZE=4><B>5.1.8.5 LOGMARS</B></FONT></P>
|
|
|
|
|
<P>LOGMARS (Logistics Applications of Automated Marking and Reading
|
|
|
|
|
Symbols) is a variation of the Code 39 symbology used by the US
|
|
|
|
|
Department of Defence. LOGMARS encodes the same character set as
|
|
|
|
|
Standard Code 39 and adds a modulo-43 check digit.</P>
|
2008-09-03 08:27:56 +12:00
|
|
|
|
<P><A NAME="CODE32"></A><FONT SIZE=4><B>5.1.8.6 Code 32</B></FONT></P>
|
|
|
|
|
<P>A variation of Code 39 used by the Italian Ministry of Health
|
|
|
|
|
(Ministero della Sanità) for encoding pharmacode data on
|
2008-09-20 18:10:34 +12:00
|
|
|
|
pharmaceutical products. Requires a numeric input up to 8 digits in
|
|
|
|
|
length. Check digit is added by Zint.</P>
|
2008-09-03 08:27:56 +12:00
|
|
|
|
<P ALIGN=CENTER><IMG SRC="code39.png" NAME="graphics8" ALIGN=LEFT WIDTH=206 HEIGHT=118 BORDER=0><BR CLEAR=LEFT><BR><BR>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
</P>
|
|
|
|
|
<P><A NAME="CODABAR"></A><FONT SIZE=5><B>5.1.9 Codabar (EN 798)</B></FONT></P>
|
|
|
|
|
<P>Also known as NW-7, Monarch, ABC Codabar, USD-4, Ames Code and
|
|
|
|
|
Code 27, this symbology was developed in 1972 by Monarch Marketing
|
|
|
|
|
Systems for retail purposes. The American Blood Commission adopted
|
|
|
|
|
Codabar in 1977 as the standard symbology for blood identification.
|
|
|
|
|
Codabar can encode any length string starting and ending with the
|
|
|
|
|
letters A-D and containing between these letters the numbers 0-9,
|
|
|
|
|
dash (-), dollar ($), colon (:), slash (/), full stop (.) or plus
|
|
|
|
|
(+). No check digit is generated.</P>
|
2008-09-03 08:27:56 +12:00
|
|
|
|
<P ALIGN=CENTER><IMG SRC="codabar.png" NAME="graphics9" ALIGN=LEFT WIDTH=164 HEIGHT=118 BORDER=0><BR CLEAR=LEFT><BR><BR>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
</P>
|
|
|
|
|
<P><A NAME="PHARMA"></A><FONT SIZE=5><B>5.1.10 Pharmacode</B></FONT></P>
|
|
|
|
|
<P>Developed by Laetus, Pharmacode One-Track is used for the
|
|
|
|
|
identification of pharmaceuticals. The symbology is able to encode
|
|
|
|
|
whole numbers between 3 and 131070.</P>
|
|
|
|
|
<P ALIGN=LEFT><IMG SRC="pharma.png" NAME="graphics10" ALIGN=LEFT WIDTH=116 HEIGHT=100 BORDER=0><BR CLEAR=LEFT><BR><BR>
|
|
|
|
|
</P>
|
|
|
|
|
<P><A NAME="CODE128"></A><FONT SIZE=5><B>5.1.11 Code 128</B></FONT></P>
|
|
|
|
|
<P><A NAME="CODE128STAND"></A><FONT SIZE=4><B>5.1.11.1 Standard Code
|
|
|
|
|
128 (ISO 15417)</B></FONT></P>
|
|
|
|
|
<P>One of the most widely used one-dimensional barcode symbologies,
|
|
|
|
|
Code 128 was developed in 1981 by Computer Identics. This symbology
|
|
|
|
|
supports full ASCII text and uses a three-mode system to compress the
|
|
|
|
|
data into a smaller symbol. Zint automatically switches between modes
|
|
|
|
|
and adds a modulo-103 check digit. Code 128 is the default barcode
|
|
|
|
|
symbology used by Zint. In addition Zint supports the encoding of
|
2008-09-03 08:27:56 +12:00
|
|
|
|
Latin-1 (non-English) characters in Code 128 symbols [1]. The Latin-1
|
2008-07-14 09:15:55 +12:00
|
|
|
|
character set is shown in <A HREF="appxa.html">Appendix A</A>.</P>
|
|
|
|
|
<P><A NAME="CODE128B"></A><FONT SIZE=4><B>5.1.11.2 Code 128 Subset B</B></FONT></P>
|
|
|
|
|
<P>It is sometimes advantageous to stop Code 128 from using subset
|
|
|
|
|
mode C which compresses numerical data. The <FONT FACE="Courier, monospace">BARCODE_CODE128B</FONT>
|
|
|
|
|
option suppresses mode C in favour of mode B.</P>
|
|
|
|
|
<P><A NAME="EAN128"></A><FONT SIZE=4><B>5.1.11.3 GS1-128</B></FONT></P>
|
|
|
|
|
<P>A variation of Code 128 also known as UCC/EAN-128, this symbology
|
|
|
|
|
is defined by the <A HREF="appxc.html">GS1 General Specification.</A>
|
|
|
|
|
Application Identifiers (AIs) should be entered using [square
|
|
|
|
|
brackets] notation. These will be converted to (round brackets) for
|
|
|
|
|
the human readable text. This will allow (round brackets) to be used
|
|
|
|
|
in the data strings to be encoded. Fixed length data should be
|
|
|
|
|
entered at the appropriate length for correct encoding - this is not
|
|
|
|
|
checked by Zint and incorrect length data will result in a symbol
|
|
|
|
|
which does not read correctly (see <A HREF="appxc.html">Appendix C</A>).
|
|
|
|
|
GS1-128 does not support extended ASCII characters. Check digits for
|
|
|
|
|
GTIN data (AI 01) are not generated and need to be included in input
|
|
|
|
|
data. The following is an example of a valid GS1-128 input:</P>
|
|
|
|
|
<P ALIGN=LEFT STYLE="font-weight: medium"><FONT FACE="Courier, monospace"><FONT SIZE=2>zint
|
|
|
|
|
--barcode=16 -d "[01]98898765432106[3202]012345[15]991231"</FONT></FONT></P>
|
2008-09-20 18:10:34 +12:00
|
|
|
|
<P><A NAME="EAN14"></A><FONT SIZE=4><B>5.1.11.4 EAN-14</B></FONT></P>
|
|
|
|
|
<P STYLE="font-weight: medium"><FONT SIZE=3>A shorter version of
|
|
|
|
|
GS1-128 which encodes GTIN data only. A 13 digit number is required.
|
|
|
|
|
GTIN check digit and AI (01) are added by Zint.</FONT></P>
|
|
|
|
|
<P><A NAME="NVE18"></A><FONT SIZE=4><B>5.1.11.5 NVE-18</B></FONT></P>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
<P>A variation of Code 128 the Nummber der Versandeinheit standard
|
|
|
|
|
includes both modulo-10 and modulo-103 check digits. NVE-18 requires
|
|
|
|
|
a 17 digit numerical input.</P>
|
2008-09-03 08:27:56 +12:00
|
|
|
|
<P ALIGN=CENTER><IMG SRC="code128.png" NAME="graphics11" ALIGN=LEFT WIDTH=246 HEIGHT=118 BORDER=0><BR CLEAR=LEFT><BR><BR>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
</P>
|
|
|
|
|
<P ALIGN=LEFT><A NAME="DATABAR"></A><FONT SIZE=5><B>5.1.12 GS1
|
|
|
|
|
DataBar (ISO 24724)</B></FONT></P>
|
|
|
|
|
<P ALIGN=LEFT>Also known as RSS (Reduced Spaced Symbology) these
|
|
|
|
|
symbols are due to replace GS1-128 symbols starting in 2010 in
|
|
|
|
|
accordance with the <A HREF="http://www.gs1uk.org/EANUCC/WORD_Files/word.html">GS1
|
|
|
|
|
General Specification.</A> If a GS1 DataBar symbol is to be printed
|
|
|
|
|
with a 2D component as specified in ISO 24723 set <FONT FACE="Courier, monospace">option_1
|
|
|
|
|
= 2</FONT> or use the option <FONT FACE="Courier, monospace">--mode=2</FONT>
|
|
|
|
|
at the command prompt. See the section <A HREF="composite.html">Composite
|
|
|
|
|
Symbols</A> to generate DataBar symbols with 2D components.</P>
|
|
|
|
|
<P ALIGN=LEFT><A NAME="RSS14"></A><FONT SIZE=4><B>5.1.12.1 DataBar-14
|
|
|
|
|
and DataBar-14 Truncated</B></FONT></P>
|
|
|
|
|
<P ALIGN=LEFT STYLE="font-weight: medium"><FONT SIZE=3>Also known as
|
|
|
|
|
RSS-14 the DataBar-14 encodes a 13 digit item code. A check digit and
|
|
|
|
|
application identifier of (01) are added by Zint. Note that for full
|
|
|
|
|
standard compliance symbol height should be greater than or equal to
|
|
|
|
|
33 modules. For DataBar-14 Truncated set the symbol height to a
|
|
|
|
|
minimum of 13.</FONT></P>
|
|
|
|
|
<P ALIGN=LEFT><A NAME="RSSLTD"></A><FONT SIZE=4><B>5.1.12.2 DataBar
|
|
|
|
|
Limited</B></FONT></P>
|
|
|
|
|
<P ALIGN=LEFT STYLE="font-weight: medium"><FONT SIZE=3>Also known as
|
|
|
|
|
RSS Limited the DataBar Limited symbol also encodes 13 digit item
|
|
|
|
|
codes and can be used in the same way as DataBar-14 above. DataBar
|
|
|
|
|
Limited, however, is limited to data starting with digits 0 and 1
|
|
|
|
|
(i.e. numbers in the range 0 to 1999999999999). As with DataBar-14 a
|
|
|
|
|
check digit and application identifier of (01) are added by Zint.</FONT></P>
|
|
|
|
|
<P ALIGN=LEFT><A NAME="RSSEXP"></A><FONT SIZE=4><B>5.1.12.3 DataBar
|
|
|
|
|
Expanded</B></FONT></P>
|
|
|
|
|
<P ALIGN=LEFT><FONT SIZE=3><SPAN STYLE="font-weight: medium">Also
|
|
|
|
|
known as RSS Expanded this is a variable length symbology capable of
|
|
|
|
|
encoding data from a number of AIs in a single symbol. AIs should be
|
|
|
|
|
encased in [square brackets] in the input data. This will be
|
|
|
|
|
converted to (rounded brackets) before it is included in the human
|
|
|
|
|
readable text attached to the symbol. This method allows the
|
|
|
|
|
inclusion of rounded brackets in the data to be encoded. GTIN data
|
|
|
|
|
(AI 01) should also include the check digit data as this is not
|
|
|
|
|
calculated by Zint when this symbology is encoded. </SPAN></FONT><SPAN STYLE="font-weight: medium">Fixed
|
|
|
|
|
length data should be entered at the appropriate length for correct
|
|
|
|
|
encoding - this is not checked by Zint and incorrect length data will
|
|
|
|
|
result in a symbol which does not read correctly (see <A HREF="appxc.html">Appendix
|
|
|
|
|
C</A>). </SPAN><FONT SIZE=3><SPAN STYLE="font-weight: medium">The
|
|
|
|
|
following is an example of a valid DataBar Expanded input</SPAN></FONT></P>
|
|
|
|
|
<P ALIGN=LEFT STYLE="font-weight: medium"><FONT FACE="Courier, monospace"><FONT SIZE=2>zint
|
|
|
|
|
--barcode=31 -d "[01]98898765432106[3202]012345[15]991231"</FONT></FONT></P>
|
2008-09-03 08:27:56 +12:00
|
|
|
|
<P ALIGN=CENTER><IMG SRC="databar.png" NAME="graphics12" ALIGN=LEFT WIDTH=302 HEIGHT=118 BORDER=0><BR CLEAR=LEFT><BR><BR>
|
|
|
|
|
</P>
|
2008-10-19 21:57:58 +13:00
|
|
|
|
<P ALIGN=LEFT>[1] The zint command line program requires Latin-1
|
|
|
|
|
characters to be encoded using the UTF-8 system. These are converted
|
|
|
|
|
by the front-end into an extended ASCII string. When using the API
|
|
|
|
|
this type conversion will need to be done before invoking the library
|
|
|
|
|
otherwise the data will become corrupted. An example program
|
|
|
|
|
<FONT FACE="Courier, monospace">exttest.c</FONT> is included in the
|
|
|
|
|
/<FONT FACE="Courier, monospace">frontend</FONT> folder to show how
|
|
|
|
|
extended ASCII can be used to produce the following symbol. Extended
|
|
|
|
|
ASCII characters may not display properly in EPS due to the
|
|
|
|
|
restrictions of the EPS format.</P>
|
2008-09-03 08:27:56 +12:00
|
|
|
|
<P ALIGN=LEFT><IMG SRC="barext.png" NAME="graphics13" ALIGN=LEFT WIDTH=246 HEIGHT=118 BORDER=0><BR CLEAR=LEFT><BR><BR>
|
2008-07-14 09:15:55 +12:00
|
|
|
|
</P>
|
|
|
|
|
<HR>
|
|
|
|
|
<TABLE WIDTH=100% BORDER=0 CELLPADDING=0 CELLSPACING=0>
|
|
|
|
|
<TR VALIGN=TOP>
|
|
|
|
|
<TD WIDTH=33% HEIGHT=5>
|
|
|
|
|
<P ALIGN=LEFT><A HREF="symbologies.html">Prev</A></P>
|
|
|
|
|
</TD>
|
|
|
|
|
<TD WIDTH=34%>
|
|
|
|
|
<P ALIGN=CENTER><A HREF="index.html">Home</A></P>
|
|
|
|
|
</TD>
|
|
|
|
|
<TD WIDTH=33%>
|
|
|
|
|
<P ALIGN=RIGHT><A HREF="stacked.html">Next</A></P>
|
|
|
|
|
</TD>
|
|
|
|
|
</TR>
|
|
|
|
|
<TR VALIGN=TOP>
|
|
|
|
|
<TD WIDTH=33%>
|
|
|
|
|
<P ALIGN=LEFT>Types of Symbol</P>
|
|
|
|
|
</TD>
|
|
|
|
|
<TD WIDTH=34%>
|
|
|
|
|
<P ALIGN=CENTER> </P>
|
|
|
|
|
</TD>
|
|
|
|
|
<TD WIDTH=33%>
|
|
|
|
|
<P ALIGN=RIGHT>Stacked Symbols</P>
|
|
|
|
|
</TD>
|
|
|
|
|
</TR>
|
|
|
|
|
</TABLE>
|
|
|
|
|
<P><BR><BR>
|
|
|
|
|
</P>
|
|
|
|
|
</BODY>
|
|
|
|
|
</HTML>
|