mirror of
https://github.com/zint/zint
synced 2024-11-16 20:57:25 +13:00
Allow explicit bind option for ITF-14
Allows for 'printing methods that do not require printing plates' as highlighted by Adham Elrayyes (Ticket #201)
This commit is contained in:
parent
e9652df70c
commit
1f57c58e0c
@ -280,10 +280,13 @@ INTERNAL int itf14(struct zint_symbol *symbol, unsigned char source[], int lengt
|
||||
error_number = interleaved_two_of_five(symbol, (unsigned char *) localstr, strlen(localstr));
|
||||
ustrcpy(symbol->text, localstr);
|
||||
|
||||
symbol->output_options |= BARCODE_BOX;
|
||||
if (symbol->border_width == 0) { /* Allow override if non-zero */
|
||||
/* GS1 General Specifications 20.0 Sections 5.3.2.4 & 5.3.6 (4.83 / 1.016 ~ 4.75) */
|
||||
symbol->border_width = 5; /* Note change from previous value 8 */
|
||||
if (!((symbol->output_options & BARCODE_BOX) || (symbol->output_options & BARCODE_BIND))) {
|
||||
// If no option has been selected then uses default box option
|
||||
symbol->output_options |= BARCODE_BOX;
|
||||
if (symbol->border_width == 0) { /* Allow override if non-zero */
|
||||
/* GS1 General Specifications 20.0 Sections 5.3.2.4 & 5.3.6 (4.83 / 1.016 ~ 4.75) */
|
||||
symbol->border_width = 5; /* Note change from previous value 8 */
|
||||
}
|
||||
}
|
||||
|
||||
return error_number;
|
||||
|
@ -369,7 +369,7 @@ Zint allows the symbol to be bound with 'boundary bars' using the option
|
||||
--bind. These bars help to prevent misreading of the symbol by corrupting a
|
||||
scan if the scanning beam strays off the top or bottom of the symbol. Zint can
|
||||
also put a border right around the symbol and its whitespace with the --box
|
||||
option. This option is automatically selected for ITF-14 symbols.
|
||||
option.
|
||||
|
||||
The width of the boundary or box can be specified using the --border switch.
|
||||
For example:
|
||||
@ -378,6 +378,9 @@ zint --box --border=10 -d "This"
|
||||
|
||||
gives a box with a width 10 times the X-dimension of the symbol.
|
||||
|
||||
These options are ignored for Code 16k and Codablock-F. Special considerations
|
||||
apply to ITF-14 - see the specific section for that symbology.
|
||||
|
||||
4.7 Using colour
|
||||
----------------
|
||||
The default colours of a symbol are a black symbol on a white background. Zint
|
||||
@ -1092,7 +1095,7 @@ Value |
|
||||
--------------------------------------------------------------------------------
|
||||
|
||||
Note: Symbologies marked with an asterisk (*) in the above table used different
|
||||
enumeration in Zint before version 2.9.0. For example, symbology 29 used the name
|
||||
names in Zint before version 2.9.0. For example, symbology 29 used the name
|
||||
"BARCODE_RSS14". These names are now depreciated but are still recognised by
|
||||
Zint and will continue to be supported in future versions.
|
||||
|
||||
@ -1168,7 +1171,8 @@ if (ZBarcode_ValidID(BARCODE_PDF417) != 0) {
|
||||
USPS Intelligent Mail, RM4SCC, PDF417, Data Matrix, Maxicode, QR Code, GS1
|
||||
DataBar Stacked, PDF417 and MicroPDF417 - all of which have a fixed height.
|
||||
|
||||
[2] This value is ignored for Code 16k, Codablock-F and ITF-14 symbols.
|
||||
[2] This value is ignored for Code 16k and Codablock-F. Special considerations
|
||||
apply to ITF-14 - see the specific section for that symbology.
|
||||
|
||||
6. Types of Symbology
|
||||
=====================
|
||||
@ -1226,6 +1230,13 @@ ITF-14, also known as UPC Shipping Container Symbol or Case Code is based on
|
||||
Interleaved Code 2 of 5 and requires a 13 digit numeric input (digits 0-9). One
|
||||
modulo-10 check digit is added by Zint.
|
||||
|
||||
If no border option is specified Zint defaults to adding a bounding box with a
|
||||
border width of 5. This behaviour can be overridden by using the --bind otion
|
||||
(or adding BARCODE_BIND to symbol->output_options). Similarly the border width
|
||||
can be overriden using --border= (or by setting symbol->border_width). If a
|
||||
symbol with no border is explicitly required this can be achieved by setting
|
||||
the border type to box or bind and setting the border width to 0.
|
||||
|
||||
6.1.2.7 Deutsche Post Leitcode
|
||||
------------------------------
|
||||
Leitcode is based on Interleaved Code 2 of 5 and is used by Deutsche Post for
|
||||
|
Loading…