diff --git a/docs/manual.html b/docs/manual.html
index 89f4422a..2e3c4581 100644
--- a/docs/manual.html
+++ b/docs/manual.html
@@ -5134,9 +5134,10 @@ aria-hidden="true"> This is a stacked symbology based on Code 128 which can encode
Latin-1 data up to a maximum length of 2725 characters. The width of the
Codablock-F symbol can be set using the zint -b CODABLOCKF -d "CODABLOCK F Symbology" --rows=3<
--cols
option (API
-option_2
). The height (number of rows) can be set using the
---rows
option (API option_1
). Zint does not
-currently support encoding of GS1 data in Codablock-F symbols.option_2
), to a value between 9 and 67. The height (number
+of rows) can be set using the --rows
option (API
+option_1
), with a maximum of 44. Zint does not currently
+support encoding of GS1 data in Codablock-F symbols.
A separate symbology ID (BARCODE_HIBC_BLOCKF
) can be
used to encode Health Industry Barcode (HIBC) data which adds a leading
'+'
character and a modulo-49 check digit to the encoded
diff --git a/docs/manual.pmd b/docs/manual.pmd
index 3d459047..201d739e 100644
--- a/docs/manual.pmd
+++ b/docs/manual.pmd
@@ -3370,9 +3370,10 @@ demonstrated by the symbologies below.
This is a stacked symbology based on Code 128 which can encode Latin-1 data up
to a maximum length of 2725 characters. The width of the Codablock-F symbol can
-be set using the `--cols` option (API `option_2`). The height (number of rows)
-can be set using the `--rows` option (API `option_1`). Zint does not currently
-support encoding of GS1 data in Codablock-F symbols.
+be set using the `--cols` option (API `option_2`), to a value between 9 and 67.
+The height (number of rows) can be set using the `--rows` option (API
+`option_1`), with a maximum of 44. Zint does not currently support encoding of
+GS1 data in Codablock-F symbols.
A separate symbology ID (`BARCODE_HIBC_BLOCKF`) can be used to encode Health
Industry Barcode (HIBC) data which adds a leading `'+'` character and a
diff --git a/docs/manual.txt b/docs/manual.txt
index 9a8cafdd..edf38342 100644
--- a/docs/manual.txt
+++ b/docs/manual.txt
@@ -3246,9 +3246,10 @@ demonstrated by the symbologies below.
This is a stacked symbology based on Code 128 which can encode Latin-1 data up
to a maximum length of 2725 characters. The width of the Codablock-F symbol can
-be set using the --cols option (API option_2). The height (number of rows) can
-be set using the --rows option (API option_1). Zint does not currently support
-encoding of GS1 data in Codablock-F symbols.
+be set using the --cols option (API option_2), to a value between 9 and 67. The
+height (number of rows) can be set using the --rows option (API option_1), with
+a maximum of 44. Zint does not currently support encoding of GS1 data in
+Codablock-F symbols.
A separate symbology ID (BARCODE_HIBC_BLOCKF) can be used to encode Health
Industry Barcode (HIBC) data which adds a leading '+' character and a modulo-49