grpMicroPDF
0
0
532
251
600
16777215
Form
-
-
Encoding &Mode:
Qt::AlignLeading|Qt::AlignLeft|Qt::AlignVCenter
Mode 2 (numeric postcode) and Mode 3 (alphanumeric postcode)
use a Structured Carrier Message (SCM) of 3 fields:
Postcode, Country Code, Service Class
Mode 4 uses enhanced ECC for the primary part of the message
Mode 5 uses enhanced ECC for all of the message
Mode 6 sets the scanner (Reader Initialisation/Programming)
cmbMaxiMode
-
0
0
Mode 2 (numeric postcode) and Mode 3 (alphanumeric postcode)
use a Structured Carrier Message (SCM) of 3 fields:
Postcode, Country Code, Service Class
Mode 4 uses enhanced ECC for the primary part of the message
Mode 5 uses enhanced ECC for all of the message
Mode 6 sets the scanner (Reader Initialisation/Programming)
1
-
Structured Carrier Message (Mode 2 or 3)
-
Standard Symbol, SEC (Mode 4)
-
Full ECC Symbol (Mode 5)
-
Reader Program, SEC (Mode 6)
-
Structured Carrier Message
For Modes 2 and 3 only
-
false
Postcode of up to 9 digits for Mode 2 or
6 alphanumerics for Mode 3 (will truncate)
Postcodes less than maximum length will
be padded with spaces
(ignored if disabled)
Pos&tcode:
Qt::AlignLeading|Qt::AlignLeft|Qt::AlignVCenter
txtMaxiSCMPostcode
-
false
Postcode of up to 9 digits for Mode 2 or
6 alphanumerics for Mode 3 (will truncate)
Postcodes less than maximum length will
be padded with spaces
(ignored if disabled)
0
0
9
-
false
ISO 3166 numeric country code
Value ranges from 000 to 999
(ignored if disabled)
Cou&ntry code:
Qt::AlignLeading|Qt::AlignLeft|Qt::AlignVCenter
spnMaxiSCMCountry
-
false
ISO 3166 numeric country code
Value ranges from 000 to 999
(ignored if disabled)
0
999
0
-
false
Class of service, assigned by carrier
Value ranges from 000 to 999
(ignored if disabled)
Se&rvice Class:
Qt::AlignLeading|Qt::AlignLeft|Qt::AlignVCenter
spnMaxiSCMService
-
false
Class of service, assigned by carrier
Value ranges from 000 to 999
(ignored if disabled)
0
999
0
-
false
Prefix Structured Carrier Message with "[)>\R01\Gvv"
(ANS MH10.8.2 Format 01) where "vv" is version given below
(ignored if disabled)
Enable S&CM Prefix
-
false
Version "vv" to place at end of SCM prefix (default 96)
(ignored if disabled)
SCM Pre&fix Version:
Qt::AlignLeading|Qt::AlignLeft|Qt::AlignVCenter
spnMaxiSCMVV
-
false
Version "vv" to place at end of SCM prefix (default 96)
(ignored if disabled)
0
99
96
-
Qt::Vertical
20