December 2023
The Zint project aims to provide a complete cross-platform open source barcode generating solution. The package currently consists of a Qt-based GUI, a CLI command line executable and a library with an API to allow developers access to the capabilities of Zint. It is hoped that Zint provides a solution which is flexible enough for professional users while at the same time takes care of as much of the processing as possible to allow easy translation from input data to barcode image.
The library which forms the main component of the Zint project is currently able to encode data in over 50 barcode symbologies (types of barcode), for each of which it is possible to translate that data from either UTF-8 (Unicode) or a raw 8-bit data stream. The image can be rendered as a
Many options are available for setting the characteristics of the output image including the size and colour of the image, the amount of error correction used in the symbol and the orientation of the image.
Some of the words and phrases used in this document are specific to barcoding, and so a brief explanation is given to help understanding:
A symbol is an image which encodes data according to one of the standards. This encompasses barcodes (linear symbols) as well as any of the other methods of representing data used in this program.
A method of encoding data to create a certain type of symbol.
A linear or one-dimensional symbol is one which consists of bars and spaces, and is what most people associate with the term ‘barcode’. Examples include Code 128.
A stacked symbol consists of multiple linear symbols placed one above another and which together hold the message, usually alongside some error correction data. Examples include PDF417.
A matrix symbol is one based on a (usually square) grid of elements called modules. Examples include Data Matrix, but MaxiCode and DotCode are also considered matrix symbologies.
A composite symbology is one which is made up of elements which are both linear and stacked. Those currently supported are made up of a linear ‘primary’ message above which is printed a stacked component based on the PDF417 symbology. These symbols also have a separator which separates the linear and the stacked components. The stacked component is most often referred to as the 2D (two-dimensional) component.
The X-dimension of a symbol is the size (usually the width) of the smallest element. For a linear symbology this is the width of the smallest bar. For matrix symbologies it is the width of the smallest module (usually a square). Barcode widths and heights are expressed in X-dimensions. Most linear symbologies can have their height varied whereas most matrix symbologies have a fixed width-to-height ratio where the height is determined by the width.
This is a structured way of representing information which consists of ‘chunks’ of data, each of which starts with an Application Identifier (AI). The AI identifies what type of information is being encoded.
Some symbologies allow a special character to be included which can be detected by the scanning equipment as signifying that the data is used to program or change settings in that equipment. This data is usually not passed on to the software which handles normal input data. This feature should only be used if you are familiar with the programming codes relevant to your scanner.
The Extended Channel Interpretations (ECI) mechanism allows for multi-language data to be encoded in symbols which would usually support only Latin-1 (ISO/IEC 8859-1 plus ASCII) characters. This can be useful, for example, if you need to encode Cyrillic characters, but should be used with caution as not all scanners support this method.
Two other concepts that are important are raster and vector.
A low level bitmap representation of an image. BMP, GIF, PCX, PNG and TIF are raster file formats.
A high level command- or data-based representation of an image. EMF, EPS and SVG are vector file formats. They require renderers to turn them into bitmaps.
The easiest way to configure compilation is to take advantage of the
CMake utilities. You will need to install CMake and
libpng-dev
first. For instance on apt
systems:
sudo apt install git cmake build-essential libpng-dev
If you want to take advantage of Zint Barcode Studio you will also
need to have Qt and its component "Desktop gcc 64-bit"
installed, as well as mesa
. For details see
"README.linux"
in the project root directory.
Once you have fulfilled these requirements unzip the source code tarball or clone the latest source
git clone https://git.code.sf.net/p/zint/code zint
and follow these steps in the top directory:
mkdir build
cd build
cmake ..
make
sudo make install
The CLI command line program can be accessed by typing
zint [options]
The GUI can be accessed by typing
zint-qt
To test that the installation has been successful a shell script is
included in the "frontend"
sub-directory. To run the test
type
./test.sh
This should create numerous files in the sub-directory
"frontend/test_sh_out"
showing the many modes of operation
which are available from Zint.
The latest Zint CLI, libzint
library and GUI can be
installed from the zint
package on FreeBSD:
su
pkg install zint
exit
and on OpenBSD (where the GUI is in a separate zint-gui
package):
su
pkg_add zint zint-gui
exit
To build from source see "README.bsd"
in the project
root directory.
For Microsoft Windows, Zint is distributed as a binary executable.
Simply download the ZIP file, then right-click on the ZIP file and
"Extract All"
. A new folder will be created within which
are two binary files:
qtZint.exe
- Zint Barcode Studiozint.exe
- Command Line InterfaceFor fresh releases you will get a warning message from Microsoft Defender SmartScreen that this is an ‘unrecognised app’. This happens because Zint is a free and open-source software project with no advertising and hence no income, meaning we are not able to afford the $664 per year to have the application digitally signed by Microsoft.
To build Zint on Windows from source, see
"win32/README"
.
The latest Zint CLI and libzint
can be installed using
Homebrew.1 To install Homebrew input the
following line into the macOS terminal
/bin/bash -c "$(curl -fsSL \
)" https://raw.githubusercontent.com/Homebrew/install/HEAD/install.sh
Once Homebrew is installed use the following command to install the CLI and library
brew install zint
To build from source (and install the GUI) see
"README.macos"
in the project root directory.
The Tcl backend in the "backend_tcl"
sub-directory may
be built using the provided TEA (Tcl Extension Architecture) build on
Linux, Windows, macOS and Android. For Windows, an MSVC6 makefile is
also available. See Annex C. Tcl
Backend Binding for further details.
Zint Barcode Studio is the graphical user interface for Zint. If you are starting from a command line interface you can start the GUI by typing
zint-qt
or on Windows
qtZint.exe
See the note in section 2.3 Microsoft Windows about Microsoft Defender SmartScreen.
Below is a brief guide to Zint Barcode Studio.
This is the main window of Zint Barcode Studio. The top of the window
shows a preview of the barcode that the current settings would create.
These settings can be changed using the controls below. The text box in
the "Data to Encode"
groupbox on this first Data tab allows
you to enter the data to be encoded. When you are happy with your
settings you can use the "Save..."
button to save the
resulting image to a file.
The "Symbology"
drop-down box gives access to all of the
symbologies supported by Zint shown in alphabetical order. The text box
to its right can filter the drop-down to only show matching symbologies.
For instance typing "mail"
will only show barcodes in the
drop-down whose names contain the word "mail"
. Each word
entered will match. So typing "mail post"
will show
barcodes whose names contain "mail"
or "post"
(or both).
The ellipsis button "..."
to the right of the data text
box invokes the Data Dialog - see 3.7 Data
Dialog for details. The delete button next to it will
clear the data text box and the ECI (Extended Channel Interpretations)
drop-down if set.
To set the barcode as a Programming Initialisation symbol click the
"Reader Init"
checkbox. The "1234.."
button to
its right invokes the Sequence Dialog - see 3.8 Sequence Dialog. The zap button will clear all data
and reset all settings for the barcode to defaults.
The "BMP"
and "SVG"
buttons at the bottom
will copy the image to the clipboard in BMP format and SVG format
respectively. Further copy-to-clipboard formats are available by
clicking the "Menu"
button, along with
"CLI Equivalent..."
, "Save As..."
,
"Factory Reset..."
, "Help"
,
"About..."
and "Quit"
options. Most of the
options are also available in a context menu by right-clicking the
preview.
In the middle of the Data tab is an area for creating composite symbologies which appears when the currently selected symbology is supported by the GS1 Composite symbology standard. GS1 data can then be entered with square brackets used to separate Application Identifier (AI) information from data as shown here. For details, see 6.3 GS1 Composite Symbols (ISO 24723).
For symbologies that support ECIs (Extended Channel Interpretations)
the middle of the Data tab is an area for entering additional data
segments with their own ECIs. Up to 4 segments (including the main
"Data to Encode"
as segment 0) may be specified. See 4.16 Multiple Segments for details.
Many symbologies have extra options to change the content, format and appearance of the symbol generated. For those with few additional options (and no support for GS1 data or ECIs), the middle of the Data tab is an area for setting those options.
Here is shown the check digit options for an Interleaved Code 2 of 5 symbol (see 6.1.2.4 Interleaved Code 2 of 5 (ISO 16390)).
Symbologies with more than a few options (or support for GS1 data or ECIs) have a second Symbology-specific tab, shown next.
A second tab appears for those symbologies with more than a few extra options.
Here is shown the options available for an Aztec Code symbol.
You can adjust its size or error correction level (see 6.6.8 Aztec Code (ISO 24778)), select how its data is to be treated (see 4.11 Input Modes), and set it as part of a Structured Append sequence of symbols (see 4.17 Structured Append).
The Appearance tab can be used to adjust the dimensions and other properties of the symbol.
The "Height"
value affects the height of symbologies
which do not have a fixed width-to-height ratio, i.e. those other than
matrix symbologies. For such symbologies the
"Automatic Height"
checkbox will be enabled - uncheck this
to manually adjust the height. The "Compliant Height"
checkbox applies to symbologies that define a standard height - see 4.4 Adjusting Height.
Boundary bars can be added with the "Border Type"
drop-down and their size adjusted with "Border Width"
, and
whitespace can be adjusted both horizontally (first spinbox) and
vertically (second spinbox), and also through the
"Quiet Zones"
checkbox if standard quiet zones are defined
for the symbology.
The size of the saved image can be specified with
"Printing Scale"
, and also by clicking the icon to invoke
the Set Printing Scale Dialog - see 4.9 Adjusting Image Size
(X-dimension) for further details.
The foreground and background colours can be set either using the
text boxes which accept "RRGGBBAA"
hexadecimal values and
"C,M,Y,K"
decimal percentage values, or by clicking the
foreground eye and background eye buttons which invoke a colour picker.
(Note that to change the colours visually, the luminence slider, the
long narrow column on the right, must be adjusted.) The color picker
only deals in RGB(A), and will overwrite any CMYK values with RGB(A)
values once "OK"
is selected.
Back in the Appearance tab, the colours can be reset to
black-on-white using the "Reset"
button, and exchanged one
for the other using the swap button next to it.
Clicking on the ellipsis "..."
button next to the
"Data to Encode"
text box in the Data tab opens a larger
window which can be used to enter longer strings of text. You can also
use this window to load data from a file.
The dialog is also available for additional ECI/Data segments by clicking the ellipsis button to the right of their data text boxes.
Note that if your data contains line feeds (LF
) then the
data will be split into separate lines in the dialog box. On saving the
data back to the main text box any separate lines in the data will be
escaped as '\n'
and the "Parse Escapes"
checkbox will be set. This only affects line feeds, not carriage returns
(CR
) or CR+LF
pairs, and behaves the same on
both Windows and Unix. (For details on escape sequences, see 4.1 Inputting Data.)
Clicking on the sequence button (labelled "1234.."
) in
the Data tab opens the Sequence Dialog. This allows you to create
multiple barcode images by entering a sequence of data inputs in the
right hand panel. Sequences can also be automatically generated by
entering parameters on the left hand side or by importing the data from
a file. Zint will generate a separate barcode image for each line of
text in the right hand panel. The format field determines the format of
the automatically generated sequence where characters have the meanings
as given below:
Character | Effect |
---|---|
$ |
Insert leading zeroes |
# |
Insert leading spaces |
* |
Insert leading asterisks |
Any other character | Interpreted literally |
Once you’re happy with the Sequence Data, click the
"Export..."
button to bring up the Export Dialog, discussed
next.
The Export Dialog invoked by pressing the "Export..."
button in the Sequence Dialog sets the parameters for exporting the
sequence of barcode images. Here you can set the output directory, the
format of the output filenames and what their image type will be. Note
that the symbology, colour and other formatting information are taken
from the main window.
The CLI Equivalent Dialog can be invoked from the main menu or the
context menu and displays the CLI command that will reproduce the
barcode as currently configured in the GUI. Press the
"Copy"
button to copy the command to the clipboard, which
can then be pasted into the command line.
This section describes how to encode data using the command line
frontend (CLI) program. The examples given are for the Unix platform,
but the same options are available for Windows - just remember to
include the executable file extension if ".EXE"
is not in
your PATHEXT
environment variable, i.e.:
zint.exe -d "This Text"
For compatibility with Windows the examples use double quotes to delimit data, though on Unix single quotes are generally preferable as they stop the shell from processing any characters such as backslash or dollar. A single quote itself is dealt with by terminating the single-quoted text, backslashing the single quote, and then continuing:
zint -d 'Text containing a single quote '\'' in the middle'
Some examples use backslash (\
) to continue commands
onto the next line. For Windows, use caret (^
) instead.
Certain options that take values have short names as well as long
ones, namely -b
(--barcode
), -d
(--data
), -i
(--input
),
-o
(--output
) and -w
(--whitesp
). For these a space should be used to separate
the short name from its value, to avoid ambiguity. For long names a
space or an equals sign may be used. For instance:
zint -d "This Text"
zint --data="This Text"
zint --data "This Text"
The examples use a space separator for short option names, and an equals sign for long option names.
The data to encode can be entered at the command line using the
-d
or --data
option, for example
zint -d "This Text"
This will encode the text "This Text"
. Zint will use the
default symbology, Code 128, and output to the default file
"out.png"
in the current directory. Alternatively, if
libpng
was not present when Zint was built, the default
output file will be "out.gif"
.
The data input to the Zint CLI is assumed to be encoded in UTF-8 (Unicode) format (Zint will correctly handle UTF-8 data on Windows). If you are encoding characters beyond the 7-bit ASCII set using a scheme other than UTF-8 then you will need to set the appropriate input options as shown in 4.11 Input Modes below.
Non-printing characters can be entered on the command line using
backslash (\
) as an escape character in combination with
the --esc
switch. Permissible sequences are shown in the
table below.
Escape Sequence | ASCII Equivalent | Name | Interpretation |
---|---|---|---|
\0 |
0x00 | NUL |
Null character |
\E |
0x04 | EOT |
End of Transmission |
\a |
0x07 | BEL |
Bell |
\b |
0x08 | BS |
Backspace |
\t |
0x09 | HT |
Horizontal Tab |
\n |
0x0A | LF |
Line Feed |
\v |
0x0B | VT |
Vertical Tab |
\f |
0x0C | FF |
Form Feed |
\r |
0x0D | CR |
Carriage Return |
\e |
0x1B | ESC |
Escape |
\G |
0x1D | GS |
Group Separator |
\R |
0x1E | RS |
Record Separator |
\\ |
0x5C | \ |
Backslash |
\dNNN |
NNN | Any 8-bit character where NNN is decimal (000-255) | |
\oNNN |
0oNNN | Any 8-bit character where NNN is octal (000-377) | |
\xNN |
0xNN | Any 8-bit character where NN is hexadecimal (00-FF) | |
\uNNNN |
Any 16-bit Unicode BMP2 character where NNNN is hexadecimal (0000-FFFF) | ||
\UNNNNNN |
Any 21-bit Unicode character where NNNNNN is hexadecimal (000000-10FFFF) |
(Special escape sequences are available for Code 128 only to manually switch Code Sets - see 6.1.10.1 Standard Code 128 (ISO 15417) for details.)
Input data can be read directly from file using the -i
or --input
switch as shown below. The input file is assumed
to be UTF-8 formatted unless an alternative mode is selected. This
command replaces the use of the -d
switch.
zint -i somefile.txt
To read from stdin specify a single hyphen "-"
as the
input file.
Note that except when batch processing (see 4.12 Batch Processing below), the file (or
stdin) should not end with a newline (LF
on Unix,
CR+LF
on Windows) unless you want the newline to be encoded
in the symbol.
Output can be directed to a file other than the default using the
-o
or --output
switch. For example:
zint -o here.png -d "This Text"
This draws a Code 128 barcode in the file "here.png"
. If
an Encapsulated PostScript file is needed simply append the filename
with ".eps"
, and so on for the other supported file
types:
zint -o there.eps -d "This Text"
The currently supported output file formats are shown in the following table.
Extension | File format |
---|---|
bmp | Windows Bitmap |
emf | Enhanced Metafile Format |
eps | Encapsulated PostScript |
gif | Graphics Interchange Format |
pcx | ZSoft Paintbrush image |
png | Portable Network Graphic |
svg | Scalable Vector Graphic |
tif | Tagged Image File Format |
txt | Text file (see 4.19 Other Options) |
The filename can contain directories and sub-directories also, which will be created if they don’t already exist:
zint -o "dir/subdir/filename.eps" -d "This Text"
Note that on Windows, filenames are assumed to be UTF-8 encoded.
Selecting which type of barcode you wish to produce (i.e. which
symbology to use) can be done at the command line using the
-b
or --barcode
switch followed by the
appropriate integer value or name in the following table. For example to
create a Data Matrix symbol you could use:
zint -b 71 -o datamatrix.png -d "Data to encode"
or
zint -b DATAMATRIX -o datamatrix.png -d "Data to encode"
Names are treated case-insensitively by the CLI, and the
BARCODE_
prefix and any underscores are optional.
Numeric Value | Name3 | Barcode Name |
---|---|---|
1 | BARCODE_CODE11 |
Code 11 |
2* |
BARCODE_C25STANDARD |
Standard Code 2 of 5 |
3 | BARCODE_C25INTER |
Interleaved 2 of 5 |
4 | BARCODE_C25IATA |
Code 2 of 5 IATA |
6 | BARCODE_C25LOGIC |
Code 2 of 5 Data Logic |
7 | BARCODE_C25IND |
Code 2 of 5 Industrial |
8 | BARCODE_CODE39 |
Code 3 of 9 (Code 39) |
9 | BARCODE_EXCODE39 |
Extended Code 3 of 9 (Code 39+) |
13 | BARCODE_EANX |
EAN (EAN-2, EAN-5, EAN-8 and EAN-13) |
14 | BARCODE_EANX_CHK |
EAN + Check Digit |
16* |
BARCODE_GS1_128 |
GS1-128 (UCC.EAN-128) |
18 | BARCODE_CODABAR |
Codabar |
20 | BARCODE_CODE128 |
Code 128 (automatic Code Set switching) |
21 | BARCODE_DPLEIT |
Deutsche Post Leitcode |
22 | BARCODE_DPIDENT |
Deutsche Post Identcode |
23 | BARCODE_CODE16K |
Code 16K |
24 | BARCODE_CODE49 |
Code 49 |
25 | BARCODE_CODE93 |
Code 93 |
28 | BARCODE_FLAT |
Flattermarken |
29* |
BARCODE_DBAR_OMN |
GS1 DataBar Omnidirectional (including GS1 DataBar Truncated) |
30* |
BARCODE_DBAR_LTD |
GS1 DataBar Limited |
31* |
BARCODE_DBAR_EXP |
GS1 DataBar Expanded |
32 | BARCODE_TELEPEN |
Telepen Alpha |
34 | BARCODE_UPCA |
UPC-A |
35 | BARCODE_UPCA_CHK |
UPC-A + Check Digit |
37 | BARCODE_UPCE |
UPC-E |
38 | BARCODE_UPCE_CHK |
UPC-E + Check Digit |
40 | BARCODE_POSTNET |
POSTNET |
47 | BARCODE_MSI_PLESSEY |
MSI Plessey |
49 | BARCODE_FIM |
FIM |
50 | BARCODE_LOGMARS |
LOGMARS |
51 | BARCODE_PHARMA |
Pharmacode One-Track |
52 | BARCODE_PZN |
PZN |
53 | BARCODE_PHARMA_TWO |
Pharmacode Two-Track |
54 | BARCODE_CEPNET |
Brazilian CEPNet |
55 | BARCODE_PDF417 |
PDF417 |
56* |
BARCODE_PDF417COMP |
Compact PDF417 (Truncated PDF417) |
57 | BARCODE_MAXICODE |
MaxiCode |
58 | BARCODE_QRCODE |
QR Code |
60 | BARCODE_CODE128AB |
Code 128 (Suppress Code Set C) |
63 | BARCODE_AUSPOST |
Australia Post Standard Customer |
66 | BARCODE_AUSREPLY |
Australia Post Reply Paid |
67 | BARCODE_AUSROUTE |
Australia Post Routing |
68 | BARCODE_AUSDIRECT |
Australia Post Redirection |
69 | BARCODE_ISBNX |
ISBN (EAN-13 with verification stage) |
70 | BARCODE_RM4SCC |
Royal Mail 4-State Customer Code (RM4SCC) |
71 | BARCODE_DATAMATRIX |
Data Matrix (ECC200) |
72 | BARCODE_EAN14 |
EAN-14 |
73 | BARCODE_VIN |
Vehicle Identification Number |
74 | BARCODE_CODABLOCKF |
Codablock-F |
75 | BARCODE_NVE18 |
NVE-18 (SSCC-18) |
76 | BARCODE_JAPANPOST |
Japanese Postal Code |
77 | BARCODE_KOREAPOST |
Korea Post |
79* |
BARCODE_DBAR_STK |
GS1 DataBar Stacked |
80* |
BARCODE_DBAR_OMNSTK |
GS1 DataBar Stacked Omnidirectional |
81* |
BARCODE_DBAR_EXPSTK |
GS1 DataBar Expanded Stacked |
82 | BARCODE_PLANET |
PLANET |
84 | BARCODE_MICROPDF417 |
MicroPDF417 |
85* |
BARCODE_USPS_IMAIL |
USPS Intelligent Mail (OneCode) |
86 | BARCODE_PLESSEY |
UK Plessey |
87 | BARCODE_TELEPEN_NUM |
Telepen Numeric |
89 | BARCODE_ITF14 |
ITF-14 |
90 | BARCODE_KIX |
Dutch Post KIX Code |
92 | BARCODE_AZTEC |
Aztec Code |
93 | BARCODE_DAFT |
DAFT Code |
96 | BARCODE_DPD |
DPD Code |
97 | BARCODE_MICROQR |
Micro QR Code |
98 | BARCODE_HIBC_128 |
HIBC Code 128 |
99 | BARCODE_HIBC_39 |
HIBC Code 39 |
102 | BARCODE_HIBC_DM |
HIBC Data Matrix ECC200 |
104 | BARCODE_HIBC_QR |
HIBC QR Code |
106 | BARCODE_HIBC_PDF |
HIBC PDF417 |
108 | BARCODE_HIBC_MICPDF |
HIBC MicroPDF417 |
110 | BARCODE_HIBC_BLOCKF |
HIBC Codablock-F |
112 | BARCODE_HIBC_AZTEC |
HIBC Aztec Code |
115 | BARCODE_DOTCODE |
DotCode |
116 | BARCODE_HANXIN |
Han Xin (Chinese Sensible) Code |
119 | BARCODE_MAILMARK_2D |
Royal Mail 2D Mailmark (CMDM) (Data Matrix) |
121 | BARCODE_MAILMARK_4S |
Royal Mail 4-State Mailmark |
128 | BARCODE_AZRUNE |
Aztec Runes |
129 | BARCODE_CODE32 |
Code 32 |
130 | BARCODE_EANX_CC |
GS1 Composite Symbol with EAN linear component |
131* |
BARCODE_GS1_128_CC |
GS1 Composite Symbol with GS1-128 linear component |
132* |
BARCODE_DBAR_OMN_CC |
GS1 Composite Symbol with GS1 DataBar Omnidirectional linear component |
133* |
BARCODE_DBAR_LTD_CC |
GS1 Composite Symbol with GS1 DataBar Limited linear component |
134* |
BARCODE_DBAR_EXP_CC |
GS1 Composite Symbol with GS1 DataBar Expanded linear component |
135 | BARCODE_UPCA_CC |
GS1 Composite Symbol with UPC-A linear component |
136 | BARCODE_UPCE_CC |
GS1 Composite Symbol with UPC-E linear component |
137* |
BARCODE_DBAR_STK_CC |
GS1 Composite Symbol with GS1 DataBar Stacked component |
138* |
BARCODE_DBAR_OMNSTK_CC |
GS1 Composite Symbol with GS1 DataBar Stacked Omnidirectional component |
139* |
BARCODE_DBAR_EXPSTK_CC |
GS1 Composite Symbol with GS1 DataBar Expanded Stacked component |
140 | BARCODE_CHANNEL |
Channel Code |
141 | BARCODE_CODEONE |
Code One |
142 | BARCODE_GRIDMATRIX |
Grid Matrix |
143 | BARCODE_UPNQR |
UPNQR (Univerzalnega Plačilnega Naloga QR) |
144 | BARCODE_ULTRA |
Ultracode |
145 | BARCODE_RMQR |
Rectangular Micro QR Code (rMQR) |
146 | BARCODE_BC412 |
IBM BC412 (SEMI T1-95) |
The height of a symbol (except those with a fixed width-to-height
ratio) can be adjusted using the --height
switch. For
example:
zint --height=100 -d "This Text"
This specifies a symbol height of 100 times the X-dimension of the symbol.
The default height of most linear barcodes is 50X, but this can be
changed for barcodes whose specifications give a standard height by
using the switch --compliantheight
. For instance
zint -b LOGMARS -d "This Text" --compliantheight
will produce a barcode of height 45.455X instead of the normal default of 50X. The flag also causes Zint to return a warning if a non-compliant height is given:
zint -b LOGMARS -d "This Text" --compliantheight --height=6.2
Warning 247: Height not compliant with standards
Another switch is --heightperrow
, which can be useful
for symbologies that have a variable number of linear rows, namely
Codablock-F, Code 16K, Code 49, GS1 DataBar Expanded Stacked,
MicroPDF417 and PDF417, as it changes the treatment of the height value
from overall height to per-row height, allowing you to specify a
consistent height for each linear row without having to know how many
there are. For instance
zint -b PDF417 -d "This Text" --height=4 --heightperrow
will produce a barcode of height 32X, with each of the 8 rows 4X high.
The amount of horizontal whitespace to the left and right of the
generated barcode can be altered using the -w
or
--whitesp
switch, in integral multiples of the X-dimension.
For example:
zint -w 10 -d "This Text"
This specifies a whitespace width of 10 times the X-dimension of the symbol both to the left and to the right of the barcode.
The amount of vertical whitespace above and below the barcode can be
altered using the --vwhitesp
switch, in integral multiples
of the X-dimension. For example for 3 times the X-dimension:
zint --vwhitesp=3 -d "This Text"
Note that the whitespace at the bottom appears below the text, if any.
Horizontal and vertical whitespace can of course be used together:
zint -b DATAMATRIX --whitesp=1 --vwhitesp=1 -d "This Text"
A --quietzones
option is also available which adds quiet
zones compliant with the symbology’s specification. This is in addition
to any whitespace specified with the --whitesp
or
--vwhitesp
switches.
Note that Codablock-F, Code 16K, Code 49, ITF-14, EAN-2 to EAN-13,
ISBN, UPC-A and UPC-E have compliant quiet zones added by default. This
can be disabled with the option --noquietzones
.
Zint allows the symbol to be bound with ‘boundary bars’ (also known
as ‘bearer bars’) using the option --bind
. These bars help
to prevent misreading of the symbol by corrupting a scan if the scanning
beam strays off the top or bottom of the symbol. Zint can also put a
border right around the symbol and its horizontal whitespace with the
--box
option.
The width of the boundary bars or box borders, in integral multiples
of the X-dimension, must be specified using the --border
switch. For example:
zint --box --border=10 -w 10 -d "This Text"
gives a box with a width 10 times the X-dimension of the symbol. Note
that when specifying a box, horizontal whitespace is usually required in
order to create a quiet zone between the barcode and the sides of the
box. To add a boundary bar to the top only use
--bindtop
.
For linear symbols, horizontal boundary bars appear tight against the barcode, inside any vertical whitespace (or text). For matrix symbols, however, where they are decorative rather than functional, boundary bars appear outside any whitespace.
Codablock-F, Code 16K and Code 49 always have boundary bars, and default to particular horizontal whitespace values. Special considerations apply to ITF-14 and DPD - see 6.1.2.6 ITF-14 and 6.1.10.7 DPD Code for those symbologies.
The default colours of a symbol are a black symbol on a white
background. Zint allows you to change this. The -r
or
--reverse
switch allows the default colours to be inverted
so that a white symbol is shown on a black background (known as
“reflectance reversal” or “reversed reflectance”). For example the
command
zint -r -d "This Text"
gives an inverted Code 128 symbol. This is not practical for most symbologies but white-on-black is allowed by the Aztec Code, Data Matrix, DotCode, Han Xin Code, Grid Matrix and QR Code symbology specifications.
For more specific needs the foreground (ink) and background (paper)
colours can be specified using the --fg
and
--bg
options followed by a number in "RRGGBB"
hexadecimal notation (the same system used in HTML) or in
"C,M,Y,K"
decimal percentages format (the latter normally
used with the --cmyk
option - see below). For example the
command
zint --fg=00FF00 -d "This Text"
alters the symbol to a bright green.
Zint also supports RGBA colour information for those output file
formats which support alpha channels (currently only GIF, PCX, PNG, SVG
and TIF, with GIF supporting either a background or foreground alpha but
not both) in a "RRGGBBAA"
format. For example:
zint --fg=00ff0055 -d "This Text"
will produce a semi-transparent green foreground with standard (white) background. Note that transparency is treated differently by raster and vector (SVG) output formats, as for vector output the background will “shine through” a transparent foreground. For instance
zint --bg=ff0000 --fg=ffffff00 ...
will give different results for PNG and SVG. Experimentation is advised!
In addition the --nobackground
option will remove the
background from all output formats except BMP.4
The --cmyk
option is specific to output in Encapsulated
PostScript (EPS) and TIF, and selects the CMYK colour space. Custom
colours should then usually be given in the comma-separated
"C,M,Y,K"
format, where C
, M
,
Y
and K
are expressed as decimal percentage
values from 0 to 100. RGB values may still be used, in which case they
will be converted formulaically to CMYK approximations.
The symbol can be rotated through four orientations using the
--rotate
option followed by the angle of rotation as shown
below.
--rotate=0 (default)
--rotate=90
--rotate=180
--rotate=270
The size of the image can be altered using the --scale
option, which sets the X-dimension. The default scale is 1.
The scale is multiplied by 2 (with the exception of MaxiCode) before being applied to the X-dimension. For MaxiCode, it is multiplied by 10 for raster output, by 40 for EMF vector output, and by 2 otherwise (non-EMF vector output).
For non-Maxicode raster output, the default scale of 1 results in an X-dimension of 2 pixels. For example for non-Maxicode PNG images a scale of 5 will increase the X-dimension to 10 pixels. For Maxicode, see 4.9.3 MaxiCode Raster Scaling below.
Scales for non-Maxicode raster output should be given in increments of 0.5, i.e. 0.5, 1, 1.5, 2, 2.5, 3, 3.5, etc., to avoid the X-dimension varying across the symbol due to interpolation. 0.5 increments are also faster to render.
The minimum scale for non-Maxicode raster output in non-dotty mode is 0.5, giving a minimum X-dimension of 1 pixel. For MaxiCode, it is 0.2. The minimum scale for raster output in dotty mode is 1 (see 4.15 Working with Dots). For raster output, text will not be printed for scales less than 1.
The minimum scale for vector output is 0.1, giving a minimum X-dimension of 0.2 (or for Maxicode EMF output, 4). The maximum scale for both raster and vector is 200.
To summarize the more intricate details:
MaxiCode? | Output | Multiplier | Min. Scale (non-dotty) | Min. Scale (dotty) |
---|---|---|---|---|
No | Raster | 2 | 0.5 | 1 |
No | Vector | 2 | 0.1 | 0.1 |
Yes | Raster | 10 | 0.2 | N/A |
Yes | Vector (non-EMF) | 2 | 0.1 | N/A |
Yes | EMF | 40 | 0.1 | N/A |
An alternative way to specify the scale, which takes the above
details into account, is to specify measurable units using the
--scalexdimdp
option, which has the format
--scalexdimdp=X[,R]
where X
is the X-dimension (in mm by default) and
R
is the resolution (in dpmm, dots per mm, by default).
R
is optional, and defaults to 12 dpmm, and X
may be zero, in which case it uses a symbology-specific default. The
units may be given in inches for X
by appending
"in"
, and in dpi (dots per inch) for R
by
appending "dpi"
. For example
zint -d "1234" --scalexdimdp=0.013in,300dpi
Explicit metric units may also be given by appending
"mm"
and "dpmm"
as appropriate, and may be
mixed with U.S. units:
zint -d "1234" --scalexdimdp=0.33mm,300dpi
The GS1 General Specifications Section 5.2.6.6 ‘Symbol dimensions at
nominal size’ gives an example of an EAN-13 barcode using the
X-dimension of 0.33mm. To print that example as a PNG at 12 dpmm, the
approximate equivalent of 300 dpi (dpi = dpmm * 25.4
),
specify a scale of 2, since 0.33 * 12 = 3.96
pixels, or 4
pixels rounding to the nearest pixel:
zint -b EANX -d "501234567890" --compliantheight --scale=2
This will result in output of 37.29mm x 25.56mm (WxH) at 12 dpmm. The
same result can be achieved using the --scalexdimdp
option
with
zint -b EANX -d "501234567890" --compliantheight --scalexdimdp=0
as 0.33mm is the default X-dimension for EAN, and 12 dpmm the default resolution.
For MaxiCode symbols, which use hexagons, the scale for raster output is multiplied by 10 before being applied. The 0.5 increment recommended for normal raster output does not apply.
The minimum scale is 0.2, so the minimum X-dimension is 2 pixels. However scales below 0.5 are not recommended and may produce symbols that are not within the following size ranges.
MaxiCode symbols have fixed size ranges of 24.82mm to 27.93mm in width, and 23.71mm to 26.69mm in height, excluding quiet zones. The default X-dimension is 0.88mm. For example, to output at the default X-dimension at 600 dpi specify:
zint -b MAXICODE -d "MaxiCode (19 chars)" --scalexdimdp=0,600dpi
For linear barcodes the text present in the output image can be
removed by using the --notext
option. Note also that for
raster output text will not be printed for scales less than 1 (see 4.9 Adjusting Image Size
(X-dimension)).
Text can be set to bold using the --bold
option, or a
smaller font can be substituted using the --small
option.
The --bold
and --small
options can be used
together if required, but only for vector output.
The gap between the barcode and the text can be adjusted using the
--textgap
option, where the gap is given in X-dimensions,
and may be negative (minimum -5X, maximum 10X). The default gap is 1X.
Note that a very small gap may cause accented texts to overlap with the
barcode:
For SVG output, the font preferred by Zint (monospaced “OCR-B” for
EAN/UPC, “Arimo” - a proportional sans-serif font metrically compatible
with “Arial” - for all others) can be embedded in the file for
portability using the --embedfont
option:
By default all CLI input data is assumed to be encoded in UTF-8 format. Many barcode symbologies encode data using the Latin-1 (ISO/IEC 8859-1 plus ASCII) character set, so input is converted from UTF-8 to Latin-1 before being put in the symbol. In addition QR Code and its variants and Han Xin Code can by default encode Japanese (Kanji) or Chinese (Hanzi) characters which are also converted from UTF-8.
There are two exceptions to the Latin-1 default: Grid Matrix, whose default character set is GB 2312 (Chinese); and UPNQR, whose default character set is Latin-2 (ISO/IEC 8859-2 plus ASCII).
Symbology | Default character sets | Alternate if input not Latin-1 |
---|---|---|
Aztec Code | Latin-1 | None |
Codablock-F | Latin-1 | None |
Code 128 | Latin-1 | None |
Code 16K | Latin-1 | None |
Code One | Latin-1 | None |
Data Matrix | Latin-1 | None |
DotCode | Latin-1 | None |
Grid Matrix | GB 2312 (includes ASCII) | N/A |
Han Xin | Latin-1 | GB 18030 (includes ASCII) |
MaxiCode | Latin-1 | None |
MicroPDF417 | Latin-1 | None |
Micro QR Code | Latin-1 | Shift JIS (includes ASCII5) |
PDF417 | Latin-1 | None |
QR Code | Latin-1 | Shift JIS (see above) |
rMQR | Latin-1 | Shift JIS (see above) |
Ultracode | Latin-1 | None |
UPNQR | Latin-2 | N/A |
All others | ASCII | N/A |
If Zint encounters characters which can not be encoded using the default character encoding then it will take advantage of the ECI (Extended Channel Interpretations) mechanism to encode the data if the symbology supports it - see 4.11.2 Input Modes and ECI below.
GS1 data can be encoded in a number of symbologies. Application
Identifiers (AIs) should be enclosed in [square brackets]
followed by the data to be encoded (see 6.1.10.3
GS1-128). To encode GS1 data use the --gs1
option. GS1
mode is assumed (and doesn’t need to be set) for GS1-128, EAN-14, GS1
DataBar and GS1 Composite symbologies but is also available for Aztec
Code, Code 16K, Code 49, Code One, Data Matrix, DotCode, QR Code and
Ultracode.
Health Industry Barcode (HIBC) data may also be encoded in the
symbologies Aztec Code, Codablock-F, Code 128, Code 39, Data Matrix,
MicroPDF417, PDF417 and QR Code. Within this mode, the leading
'+'
and the check character are automatically added by
Zint, conforming to HIBC Labeler Identification Code (HIBC LIC). For
HIBC Provider Applications Standard (HIBC PAS), preface the data with a
slash '/'
.
The --binary
option encodes the input data as given.
Automatic code page translation to an ECI page is disabled, and no
validation of the data’s encoding takes place. This may be used for raw
binary or binary encrypted data. This switch plays together with the
built-in ECI logic and examples may be found below.
The --fullmultibyte
option uses the multibyte modes of
QR Code, Micro QR Code, Rectangular Micro QR Code, Han Xin Code and Grid
Matrix for non-ASCII data, maximizing density. This is achieved by using
compression designed for Kanji/Hanzi characters; however some decoders
take blocks which are encoded this way and interpret them as Kanji/Hanzi
characters, thus causing data corruption. Symbols encoded with this
option should be checked against decoders before they are used. The
popular open-source ZXing decoder is known to exhibit this
behaviour.
If your data contains characters that are not in the default character set, you may encode it using an ECI-aware symbology and an ECI value from Table : ECI Codes below. The ECI information is added to your code symbol as prefix data. The symbologies that support ECI are
Aztec Code | Grid Matrix | PDF417 |
Code One | Han Xin Code | QR Code |
Data Matrix | MaxiCode | rMQR |
DotCode | MicroPDF417 | Ultracode |
Be aware that not all barcode readers support ECI mode, so this can sometimes lead to unreadable barcodes. If you are using characters beyond those supported by the default character set then you should check that the resulting barcode can be understood by your target barcode reader.
The ECI value may be specified with the --eci
switch,
followed by the value in the column "ECI Code"
in the table
below. The input data should be UTF-8 formatted. Zint automatically
translates the data into the target encoding.
ECI Code | Character Encoding Scheme (ISO/IEC 8859 schemes include ASCII) |
---|---|
3 | ISO/IEC 8859-1 - Latin alphabet No. 1 |
4 | ISO/IEC 8859-2 - Latin alphabet No. 2 |
5 | ISO/IEC 8859-3 - Latin alphabet No. 3 |
6 | ISO/IEC 8859-4 - Latin alphabet No. 4 |
7 | ISO/IEC 8859-5 - Latin/Cyrillic alphabet |
8 | ISO/IEC 8859-6 - Latin/Arabic alphabet |
9 | ISO/IEC 8859-7 - Latin/Greek alphabet |
10 | ISO/IEC 8859-8 - Latin/Hebrew alphabet |
11 | ISO/IEC 8859-9 - Latin alphabet No. 5 (Turkish) |
12 | ISO/IEC 8859-10 - Latin alphabet No. 6 (Nordic) |
13 | ISO/IEC 8859-11 - Latin/Thai alphabet |
15 | ISO/IEC 8859-13 - Latin alphabet No. 7 (Baltic) |
16 | ISO/IEC 8859-14 - Latin alphabet No. 8 (Celtic) |
17 | ISO/IEC 8859-15 - Latin alphabet No. 9 |
18 | ISO/IEC 8859-16 - Latin alphabet No. 10 |
20 | Shift JIS (JIS X 0208 and JIS X 0201) |
21 | Windows 1250 - Latin 2 (Central Europe) |
22 | Windows 1251 - Cyrillic |
23 | Windows 1252 - Latin 1 |
24 | Windows 1256 - Arabic |
25 | UTF-16BE (High order byte first) |
26 | UTF-8 |
27 | ASCII (ISO/IEC 646 IRV) |
28 | Big5 (Taiwan) Chinese Character Set |
29 | GB 2312 (PRC) Chinese Character Set |
30 | Korean Character Set EUC-KR (KS X 1001:2002) |
31 | GBK Chinese Character Set |
32 | GB 18030 Chinese Character Set |
33 | UTF-16LE (Low order byte first) |
34 | UTF-32BE (High order bytes first) |
35 | UTF-32LE (Low order bytes first) |
170 | ISO/IEC 646 Invariant6 |
899 | 8-bit binary data |
An ECI value of 0 does not encode any ECI information in the code symbol (unless the data contains non-default character set characters). In this case, the default character set applies (see Table : Default Character Sets above).
If no ECI is specified or a value of 0 is given, and the data does
contain characters other than in the default character set, then Zint
will automatically insert the appropriate single-byte ECI if possible
(ECIs 3 to 24, excluding ECI 20), or failing that ECI 26 (UTF-8). A
warning will be generated. This mechanism is not applied if the
--binary
option is given.
Multiple ECIs can be specified using the --segN
options
- see 4.16 Multiple Segments.
Note: the --eci=3
specification should only be used for
special purposes. Using this parameter, the ECI information is
explicitly added to the symbol. Nevertheless, for ECI Code 3, this is
not usually required, as this is the default encoding for most barcodes,
which is also active without any ECI information.
The Euro sign U+20AC can be encoded in ISO/IEC 8859-15. The Euro sign
has the ISO/IEC 8859-15 codepoint hex "A4"
. It is encoded
in UTF-8 as the hex sequence: "E2 82 AC"
. Those 3 bytes are
contained in the file "utf8euro.txt"
. This command will
generate the corresponding code:
zint -b 71 --scale=10 --eci=17 -i utf8euro.txt
This is equivalent to the commands (using the --esc
switch):
zint -b 71 --scale=10 --eci=17 --esc -d "\xE2\x82\xAC"
zint -b 71 --scale=10 --eci=17 --esc -d "\u20AC"
and to the command:
zint -b 71 --scale=10 --eci=17 -d "€"
The Chinese character with the Unicode codepoint U+5E38 can be
encoded in Big5 encoding. The Big5 representation of this character is
the two hex bytes: "B1 60"
(contained in the file
"big5char.txt"
). The generation command for Data Matrix
is:
zint -b 71 --scale=10 --eci=28 --binary -i big5char.txt
This is equivalent to the command (using the --esc
switch):
zint -b 71 --scale=10 --eci=28 --binary --esc -d "\xB1\x60"
and to the commands (no --binary
switch so conversion
occurs):
zint -b 71 --scale=10 --eci=28 --esc -d "\xE5\xB8\xB8"
zint -b 71 --scale=10 --eci=28 --esc -d "\u5E38"
zint -b 71 --scale=10 --eci=28 -d "常"
Some decoders (in particular mobile app ones) for QR Code assume
UTF-8 encoding by default and do not support ECI. In this case supply
UTF-8 data and use the --binary
switch so that the data
will be encoded as UTF-8 without conversion:
zint -b 58 --binary -d "UTF-8 data"
Data can be batch processed by reading from a text file and producing
a separate barcode image for each line of text in that file. To do this
use the --batch
switch together with -i
to
select the input file from which to read data. For example
zint -b EANX --batch -i ean13nos.txt
where "ean13nos.txt"
contains a list of EAN-13 numbers
(GTINs), each on its own line. Zint will automatically detect the end of
a line of text (in either Unix or Windows formatted text files) and
produce a symbol each time it finds this.
Input files should end with a line feed character - if this is not present then Zint will not encode the last line of text, and will warn you that there is a problem.
By default Zint will output numbered filenames starting with
00001.png
, 00002.png
etc. To change this
behaviour specify the -o
option using special characters in
the output filename as shown in the table below:
Input Character | Interpretation |
---|---|
~ |
Insert a number or 0 |
# |
Insert a number or space |
@ |
Insert a number or * (or
+ on Windows) |
Any other | Insert literally |
For instance
zint -b EANX --batch -i ean13nos.txt -o file~~~.svg
The following table shows some examples to clarify this method:
Input | Filenames Generated |
---|---|
-o file~~~.svg |
"file001.svg" ,
"file002.svg" , "file003.svg" |
-o @@@@bar.png |
"***1.png" ,
"***2.png" , "***3.png" (except Windows) |
-o @@@@bar.png |
"+++1.png" ,
"+++2.png" , "+++3.png" (on Windows) |
-o my~~~bar.eps |
"my001bar.eps" ,
"my002bar.eps" , "my003bar.eps" |
-o t#es~t~.png |
"t es0t1.png" ,
"t es0t2.png" , "t es0t3.png" |
The special characters can span directories also, which is useful when creating a large number of barcodes:
Input | Filenames Generated |
---|---|
-o dir~/file~~~.svg |
"dir0/file001.svg" ,
"dir0/file002.svg" , … |
, "dir0/file999.svg" ,
"dir1/file000.svg" , … |
For an alternative method of naming output files see the
--mirror
option in 4.14
Automatic Filenames below.
The finished image files can be output directly to stdout for use as
part of a pipe by using the --direct
option. By default
--direct
will output data as a PNG image (or GIF image if
libpng
is not present), but this can be altered by
supplementing the --direct
option with a
--filetype
option followed by the suffix of the file type
required. For example:
zint -b 84 --direct --filetype=pcx -d "Data to encode"
This command will output the symbol as a PCX file to stdout. For the supported output file formats see Table : Output File Formats.
CAUTION: Outputting binary files to the command shell without catching that data in a pipe can have unpredictable results. Use with care!
The --mirror
option instructs Zint to use the data to be
encoded as an indicator of the filename to be used. This is particularly
useful if you are processing batch data. For example the input data
"1234567"
will result in a file named
"1234567.png"
.
There are restrictions, however, on what characters can be stored in a filename, so the filename may vary from the data if the data includes non-printable characters, for example, and may be shortened if the data input is long.
To set the output file format use the --filetype
option
as detailed above in 4.13 Direct
Output to stdout. To output to a specific directory use the
-o
option giving the name of the directory (any filename
will be ignored, unless --filetype
is not specified, in
which case the filename’s extension will be used).
Matrix codes can be rendered as a series of dots or circles rather
than the normal squares by using the --dotty
option. This
option is only available for matrix symbologies, and is automatically
selected for DotCode. The size of the dots can be adjusted using the
--dotsize
option followed by the diameter of the dot, where
that diameter is in X-dimensions. The minimum dot size is 0.01, the
maximum is 20. The default size is 0.8.
The default and minimum scale for raster output in dotty mode is 1.
If you need to specify different ECIs for different sections of the
input data, the --seg1
to --seg9
options can
be used. Each option is of the form --segN=ECI,data
where
ECI
is the ECI code (see Table :
ECI Codes) and data
is the data to which this applies.
This is in addition to the ECI and data specified using the
--eci
and -d
options which must still be
present and which in effect constitute segment 0. For instance
zint -b AZTEC_CODE --eci=9 -d "Κείμενο" --seg1=7,"Текст" --seg2=20,"文章"
specifies 3 segments: segment 0 with ECI 9 (Greek), segment 1 with ECI 7 (Cyrillic), and segment 2 with ECI 20 (Shift JIS). Segments must be consecutive.
Naturally the symbology must be ECI-aware (see Table : ECI-Aware Symbologies).
ECIs of zero may be given, in which case Zint will automatically determine an ECI if necessary, as described in section 4.11.2 Input Modes and ECI.
Multiple segments are not currently supported for use with GS1 data.
Structured Append is a method of splitting data among several symbols so that they form a sequence that can be scanned and re-assembled in the correct order on reading, and is available for Aztec Code, Code One, Data Matrix, DotCode, Grid Matrix, MaxiCode, MicroPDF417, PDF417, QR Code and Ultracode.
The --structapp
option marks a symbol as part of a
Structured Append sequence, and has the format
--structapp=I,C[,ID]
where I
is the index (position) of the symbol in the
Structured Append sequence, C
is the count or total number
of symbols in the sequence, and ID
is an optional
identifier (not available for Code One, DotCode or MaxiCode) that is the
same for all symbols belonging to the same sequence. The index is
1-based and goes from 1 to count. Count must be 2 or more. See the
individual symbologies for further details.
There are three help options which give information about how to use
the command line. The -h
or --help
option will
display a list of all of the valid options available, and also gives the
exact version of the software (the version by itself can be displayed
with -v
or --version
).
The -t
or --types
option gives the table of
symbologies along with the symbol ID numbers and names.
The -e
or --ecinos
option gives a list of
the ECI codes.
Zint can output a representation of the symbol data as a set of
hexadecimal values if asked to output to a text file
("*.txt"
) or if given the option
--filetype=txt
. This can be used for test and diagnostic
purposes.
Additional options are available which are specific to certain symbologies. These may, for example, control the amount of error correction data or the size of the symbol. These options are discussed in section 6. Types of Symbology of this guide.
Zint has been written using the C language and has an API for use
with C/C++ language programs. A Qt interface (see Annex B. Qt Backend QZint) is
available in the "backend_qt"
sub-directory, and a Tcl
interface is available in the "backend_tcl"
sub-directory
(see Annex C. Tcl Backend
Binding).
The libzint
API has been designed to be very similar to
that used by the GNU Barcode package. This allows easy migration from
GNU Barcode to Zint. Zint, however, uses none of the same function names
or option names as GNU Barcode. This allows you to use both packages in
your application without conflict if you wish.
The symbols manipulated by Zint are held in a
zint_symbol
structure defined in "zint.h"
.
These symbol structures are created with the
ZBarcode_Create()
function and deleted using the
ZBarcode_Delete()
function. For example the following code
creates and then deletes a symbol:
#include <zint.h>
#include <stdio.h>
int main()
{
struct zint_symbol *my_symbol;
= ZBarcode_Create();
my_symbol if (my_symbol != NULL) {
("Symbol successfully created!\n");
printf(my_symbol);
ZBarcode_Delete}
return 0;
}
When compiling this code it will need to be linked with the
libzint
library using the -lzint
option:
gcc -o simple simple.c -lzint
To encode data in a barcode use the ZBarcode_Encode()
function. To write the symbol to a file use the
ZBarcode_Print()
function. For example the following code
takes a string from the command line and outputs a Code 128 symbol to a
PNG file named "out.png"
(or a GIF file
"out.gif"
if libpng
is not present) in the
current working directory:
#include <zint.h>
int main(int argc, char **argv)
{
struct zint_symbol *my_symbol;
= ZBarcode_Create();
my_symbol (my_symbol, argv[1], 0);
ZBarcode_Encode(my_symbol, 0);
ZBarcode_Print(my_symbol);
ZBarcode_Deletereturn 0;
}
This can also be done in one stage using the
ZBarcode_Encode_and_Print()
function as shown in the next
example:
#include <zint.h>
int main(int argc, char **argv)
{
struct zint_symbol *my_symbol;
= ZBarcode_Create();
my_symbol (my_symbol, argv[1], 0, 0);
ZBarcode_Encode_and_Print(my_symbol);
ZBarcode_Deletereturn 0;
}
Note that when using the API, the input data is assumed to be 8-bit
binary unless the input_mode
member of the
zint_symbol
structure is set - see 5.10 Setting the Input Mode for
details.
The functions for encoding and printing barcodes are defined as:
int ZBarcode_Encode(struct zint_symbol *symbol,
const unsigned char *source, int length);
int ZBarcode_Encode_File(struct zint_symbol *symbol,
const char *filename);
int ZBarcode_Print(struct zint_symbol *symbol, int rotate_angle);
int ZBarcode_Encode_and_Print(struct zint_symbol *symbol,
const unsigned char *source, int length, int rotate_angle);
int ZBarcode_Encode_File_and_Print(struct zint_symbol *symbol,
const char *filename, int rotate_angle);
In these definitions length
can be used to set the
length of the input string. This allows the encoding of NUL
(ASCII 0) characters in those symbologies which allow this. A value of 0
(or less than 0) will disable this usage and Zint will encode data up to
the first NUL
character in the input string, which must be
present.
The rotate_angle
value can be used to rotate the image
when outputting. Valid values are 0, 90, 180 and 270.
The ZBarcode_Encode_File()
and
ZBarcode_Encode_File_and_Print()
functions can be used to
encode data read directly from a text file where the filename is given
in the NUL
-terminated filename
string. The
special filename "-"
(single hyphen) can be used to read
from stdin. Note that on Windows, filenames are assumed to be UTF-8
encoded.
If printing more than one barcode, the zint_symbol
structure may be re-used by calling the ZBarcode_Clear()
function after each barcode to free any output buffers allocated. The
zint_symbol
input members must be reset. To fully restore
zint_symbol
to its default state, call
ZBarcode_Reset()
instead.
In addition to saving barcode images to file Zint allows you to access a representation of the resulting bitmap image in memory. The following functions allow you to do this:
int ZBarcode_Buffer(struct zint_symbol *symbol, int rotate_angle);
int ZBarcode_Encode_and_Buffer(struct zint_symbol *symbol,
const unsigned char *source, int length, int rotate_angle);
int ZBarcode_Encode_File_and_Buffer(struct zint_symbol *symbol,
const char *filename, int rotate_angle);
The arguments here are the same as above, and rotation and colour
options can be used with the buffer functions in the same way as when
saving to a file. The difference is that instead of saving the image to
a file it is placed in a byte (unsigned char
) array pointed
to by the bitmap
member, with bitmap_width
set
to the number of columns and bitmap_height
set to the
number of rows.
The RGB channels are split into 3 consecutive red, green, blue bytes
per pixel, and there are bitmap_width
pixels per row and
bitmap_height
rows, so the total size of the
bitmap
array is
3 * bitmap_width * bitmap_height
.
If the background and/or foreground are RGBA then the byte array
alphamap
will also be set, with a single alpha value for
each pixel. Its total size will be
bitmap_width * bitmap_height
.
The pixel data can be extracted from the array (or arrays) by the
method shown in the example below, where render_rgb()
and
render_rgba()
are assumed to be functions for drawing an
RGB and RGBA pixel on the screen implemented by the client
application:
int row, col, i = 0, j = 0;
int red, blue, green, alpha;
for (row = 0; row < my_symbol->bitmap_height; row++) {
for (col = 0; col < my_symbol->bitmap_width; col++) {
= (int) my_symbol->bitmap[i];
red = (int) my_symbol->bitmap[i + 1];
green = (int) my_symbol->bitmap[i + 2];
blue if (my_symbol->alphamap) {
= (int) my_symbol->alphamap[j];
alpha (row, col, red, green, blue, alpha);
render_rgba++;
j} else {
(row, col, red, green, blue);
render_rgb}
+= 3;
i }
}
Where speed is important, the buffer can be returned instead in a
more compact intermediate form using the output option
OUT_BUFFER_INTERMEDIATE
. Here each byte is an ASCII value:
'1'
for foreground colour and '0'
for
background colour, except for Ultracode, which also uses colour codes:
'W'
for white, 'C'
for cyan, 'B'
for blue, 'M'
for magenta, 'R'
for red,
'Y'
for yellow, 'G'
for green, and
'K'
for black. Alpha values are not reported
(alphamap
will always be NULL
). The loop for
accessing the data is then:
int row, col, i = 0;
for (row = 0; row < my_symbol->bitmap_height; row++) {
for (col = 0; col < my_symbol->bitmap_width; col++) {
(row, col, my_symbol->bitmap[i]);
render_pixel++;
i}
}
Symbols can also be saved to memory in a vector representation as well as a bitmap one. The following functions, exactly analogous to the ones above, allow you to do this:
int ZBarcode_Buffer_Vector(struct zint_symbol *symbol, int rotate_angle);
int ZBarcode_Encode_and_Buffer_Vector(struct zint_symbol *symbol,
const unsigned char *source, int length, int rotate_angle);
int ZBarcode_Encode_File_and_Buffer_Vector(struct zint_symbol *symbol,
const char *filename, int rotate_angle);
Here the vector
member is set to point to a
zint_vector
header structure which contains pointers to
lists of structures representing the various elements of the barcode:
rectangles, hexagons, strings and circles. To draw the barcode, each of
the element types is iterated in turn, and using the information stored
is drawn by a rendering system. For instance, to draw a barcode using a
rendering system with prepare_canvas()
,
draw_rect()
, draw_hexagon()
,
draw_string()
, and draw_circle()
routines
available:
struct zint_vector_rect *rect;
struct zint_vector_hexagon *hex;
struct zint_vector_string *string;
struct zint_vector_circle *circle;
(my_symbol->vector->width, my_symbol->vector->height,
prepare_canvas->scale, my_symbol->fgcolour, my_symbol->bgcolour,
my_symbol);
rotate_angle
for (rect = my_symbol->vector->rectangles; rect; rect = rect->next) {
(rect->x, rect->y, rect->width, rect->height,
draw_rect->colour);
rect}
for (hex = my_symbol->vector->hexagons; hex; hex = hex->next) {
(hex->x, hex->y, hex->diameter, hex->rotation);
draw_hexagon}
for (string = my_symbol->vector->strings; string; string = string->next) {
(string->x, string->y, string->fsize,
draw_string->rotation, string->halign,
string->text, string->length);
string}
for (circle = my_symbol->vector->circles; circle; circle = circle->next) {
(circle->x, circle->y, circle->diameter, circle->width);
draw_circle}
So far our application is not very useful unless we plan to only make
Code 128 symbols and we don’t mind that they only save to
"out.png"
. As with the CLI program, of course, these
options can be altered. The way this is done is by altering the contents
of the zint_symbol
structure between the creation and
encoding stages. The zint_symbol
structure consists of the
following members:
Member Name | Type | Meaning | Default Value |
---|---|---|---|
symbology |
integer | Symbol to use - see 5.8 Specifying a Symbology. | BARCODE_CODE128 |
height |
float | Symbol height in X-dimensions, excluding fixed width-to-height symbols.7 | Symbol dependent |
scale |
float | Scale factor for adjusting size of image (sets X-dimension). | 1.0 |
whitespace_width |
integer | Horizontal whitespace width in X-dimensions. | 0 |
whitespace_height |
integer | Vertical whitespace height in X-dimensions. | 0 |
border_width |
integer | Border width in X-dimensions. | 0 |
output_options |
integer | Set various output parameters - see 5.9 Adjusting Output Options. | 0 (none) |
fgcolour |
character string | Foreground (ink) colour as RGB/RGBA
hexadecimal string or "C,M,Y,K" decimal percentages string,
with a terminating NUL . |
"000000" |
bgcolour |
character string | Background (paper) colour as RGB/RGBA
hexadecimal string or "C,M,Y,K" decimal percentages string,
with a terminating NUL . |
"ffffff" |
fgcolor |
pointer | Points to fgcolour allowing alternate spelling. | |
bgcolor |
pointer | Points to bgcolour allowing alternate spelling. | |
outfile |
character string | Contains the name of the file to output a
resulting barcode symbol to. Must end in .png ,
.gif , .bmp , .emf ,
.eps , .pcx , .svg ,
.tif or .txt followed by a terminating
NUL .8 |
"out.png" |
primary |
character string | Primary message data for more complex
symbols, with a terminating NUL . |
"" (empty) |
option_1 |
integer | Symbol specific options. | -1 |
option_2 |
integer | Symbol specific options. | 0 |
option_3 |
integer | Symbol specific options. | 0 |
show_hrt |
integer | Set to 0 to hide Human Readable Text (HRT). | 1 |
input_mode |
integer | Set encoding of input data - see 5.10 Setting the Input Mode. | DATA_MODE |
eci |
integer | Extended Channel Interpretation code. | 0 (none) |
dpmm |
float | Resolution of output in dots per mm (BMP, EMF, PCX, PNG and TIF only). | 0 (none) |
dot_size |
float | Diameter of dots used in dotty mode (in X-dimensions). | 0.8 |
text_gap |
float | Gap between barcode and text (HRT) in X-dimensions. | 1.0 |
guard_descent |
float | Height of guard bar descent (EAN/UPC only) in X-dimensions. | 5.0 |
structapp |
Structured Append structure | Mark a symbol as part of a sequence of symbols. | count 0 (disabled) |
debug |
integer | Debugging flags. | 0 |
warn_level |
integer | Affects error/warning value returned by Zint API - see 5.7 Handling Errors. | WARN_DEFAULT |
text |
unsigned character string | Human Readable Text, which usually
consists of input data plus one more check digit. Uses UTF-8 formatting,
with a terminating NUL . |
"" (empty) (output only) |
rows |
integer | Number of rows used by the symbol. | (output only) |
width |
integer | Width of the generated symbol. | (output only) |
encoded_data |
array of unsigned character arrays | Representation of the encoded data. | (output only) |
row_height |
array of floats | Heights of each row. | (output only) |
errtxt |
character string | Error message in the event that an error
occurred, with a terminating NUL - see 5.7 Handling Errors. |
(output only) |
bitmap |
pointer to unsigned character array | Pointer to stored bitmap image - see 5.4 Buffering Symbols in Memory (raster). | (output only) |
bitmap_width |
integer | Width of stored bitmap image (in pixels) -
see bitmap member. |
(output only) |
bitmap_height |
integer | Height of stored bitmap image (in pixels)
- see bitmap member. |
(output only) |
alphamap |
pointer to unsigned character array | Pointer to array representing alpha
channel of stored bitmap image (or NULL if no alpha channel
used) - see bitmap member. |
(output only) |
vector |
pointer to vector structure | Pointer to vector header containing pointers to vector elements - see 5.5 Buffering Symbols in Memory (vector). | (output only) |
To alter these values use the syntax shown in the example below. This code has the same result as the previous example except the output is now taller and plotted in green.
#include <zint.h>
#include <string.h>
int main(int argc, char **argv)
{
struct zint_symbol *my_symbol;
= ZBarcode_Create();
my_symbol (my_symbol->fgcolour, "00ff00");
strcpy->height = 400.0f;
my_symbol(my_symbol, argv[1], 0, 0);
ZBarcode_Encode_and_Print(my_symbol);
ZBarcode_Deletereturn 0;
}
Note that background removal for all outputs except BMP can be
achieved by setting the background alpha to "00"
where the
values for R, G and B will be ignored:
(my_symbol->bgcolour, "55555500"); strcpy
This is what the CLI option --nobackground
does - see 4.7 Using Colour.
If errors occur during encoding a non-zero integer value is passed
back to the calling application. In addition the errtxt
member is set to a message detailing the nature of the error. The errors
generated by Zint are:
Return Value | Meaning |
---|---|
ZINT_WARN_HRT_TRUNCATED |
The Human Readable Text returned in
text was truncated (maximum 199 bytes). |
ZINT_WARN_INVALID_OPTION |
One of the values in
zint_struct was set incorrectly but Zint has made a guess
at what it should have been and generated a barcode accordingly. |
ZINT_WARN_USES_ECI |
Zint has automatically inserted an ECI character. The symbol may not be readable with some readers. |
ZINT_WARN_NONCOMPLIANT |
The symbol was created but is not compliant with certain standards set in its specification (e.g. height, GS1 AI data lengths). |
ZINT_ERROR |
Marks the divide between warnings and errors. For return values greater than or equal to this no symbol (or only an incomplete symbol) is generated. |
ZINT_ERROR_TOO_LONG |
The input data is too long or too short for the selected symbology. No symbol has been generated. |
ZINT_ERROR_INVALID_DATA |
The data to be encoded includes characters which are not permitted by the selected symbology (e.g. alphabetic characters in an EAN symbol). No symbol has been generated. |
ZINT_ERROR_INVALID_CHECK |
Data with an incorrect check digit has been entered. No symbol has been generated. |
ZINT_ERROR_INVALID_OPTION |
One of the values in
zint_struct was set incorrectly and Zint was unable (or
unwilling) to guess what it should have been. No symbol has been
generated. |
ZINT_ERROR_ENCODING_PROBLEM |
A problem has occurred during encoding of the data. This should never happen. Please contact the developer if you encounter this error. |
ZINT_ERROR_FILE_ACCESS |
Zint was unable to open the requested output file. This is usually a file permissions problem. |
ZINT_ERROR_MEMORY |
Zint ran out of memory. This should only be a problem with legacy systems. |
ZINT_ERROR_FILE_WRITE |
Zint failed to write all contents to the requested output file. This should only occur if the output device becomes full. |
ZINT_ERROR_USES_ECI |
Returned if warn_level set to
WARN_FAIL_ALL and ZINT_WARN_USES_ECI
occurs. |
ZINT_ERROR_NONCOMPLIANT |
Returned if warn_level set to
WARN_FAIL_ALL and ZINT_WARN_NONCOMPLIANT
occurs. |
ZINT_ERROR_HRT_TRUNCATED |
Returned if warn_level set to
WARN_FAIL_ALL and ZINT_WARN_HRT_TRUNCATED
occurs. |
To catch errors use an integer variable as shown in the code below:
#include <zint.h>
#include <stdio.h>
#include <string.h>
int main(int argc, char **argv)
{
struct zint_symbol *my_symbol;
int error;
= ZBarcode_Create();
my_symbol /* Set invalid foreground colour */
(my_symbol->fgcolour, "nonsense");
strcpy= ZBarcode_Encode_and_Print(my_symbol, argv[1], 0, 0);
error if (error != 0) {
/* Some warning or error occurred */
("%s\n", my_symbol->errtxt);
printfif (error >= ZINT_ERROR) {
/* Stop now */
(my_symbol);
ZBarcode_Deletereturn 1;
}
}
/* Otherwise carry on with the rest of the application */
(my_symbol);
ZBarcode_Deletereturn 0;
}
This code will exit with the appropriate message:
Error 881: Malformed foreground RGB colour 'nonsense' (hexadecimal only)
To treat all warnings as errors, set
symbol->warn_level
to WARN_FAIL_ALL
.
Symbologies can be specified by number or by name as shown in the Table : Barcode Types (Symbologies). For example
->symbology = BARCODE_LOGMARS; symbol
means the same as
->symbology = 50; symbol
The output_options
member can be used to adjust various
aspects of the output file. To select more than one option from the
table below simply OR
them together when adjusting this
value:
->output_options |= BARCODE_BIND | READER_INIT; my_symbol
Value | Effect |
---|---|
0 | No options selected. |
BARCODE_BIND_TOP |
Boundary bar above the symbol only.9 |
BARCODE_BIND |
Boundary bars above and below the symbol and between rows if stacking multiple symbols.10 |
BARCODE_BOX |
Add a box surrounding the symbol and whitespace. |
BARCODE_STDOUT |
Output the file to stdout. |
READER_INIT |
Create as a Reader Initialisation (Programming) symbol. |
SMALL_TEXT |
Use a smaller font for the Human Readable Text. |
BOLD_TEXT |
Embolden the Human Readable Text. |
CMYK_COLOUR |
Select the CMYK colour space option for Encapsulated PostScript and TIF files. |
BARCODE_DOTTY_MODE |
Plot a matrix symbol using dots rather than squares. |
GS1_GS_SEPARATOR |
Use GS (Group Separator) instead of FNC1 as GS1 separator (Data Matrix only). |
OUT_BUFFER_INTERMEDIATE |
Return the bitmap buffer as ASCII values instead of separate colour channels - see 5.4 Buffering Symbols in Memory (raster). |
BARCODE_QUIET_ZONES |
Add compliant quiet zones (additional to any specified whitespace).11 |
BARCODE_NO_QUIET_ZONES |
Disable quiet zones, notably those with defaults. |
COMPLIANT_HEIGHT |
Warn if height specified not compliant, or use standard height (if any) as default. |
EANUPC_GUARD_WHITESPACE |
Add quiet zone indicators (“<” and/or “>”) to HRT whitespace (EAN/UPC). |
EMBED_VECTOR_FONT |
Embed font in vector output - currently available for SVG output only. |
The way in which the input data is encoded can be set using the
input_mode
member. Valid values are shown in the table
below.
Value | Effect |
---|---|
DATA_MODE |
Uses full 8-bit range interpreted as binary data. |
UNICODE_MODE |
Uses UTF-8 input. |
GS1_MODE |
Encodes GS1 data using FNC1 characters. |
The above are exclusive, the following optional and OR-ed. | |
ESCAPE_MODE |
Process input data for escape sequences. |
GS1PARENS_MODE |
Parentheses (round brackets) used in GS1 data instead of square brackets to delimit Application Identifiers (parentheses must not otherwise occur in the data). |
GS1NOCHECK_MODE |
Do not check GS1 data for validity, i.e. suppress checks for valid AIs and data lengths. Invalid characters (e.g. control characters, extended ASCII characters) are still checked for. |
HEIGHTPERROW_MODE |
Interpret the height member
as per-row rather than as overall height. |
FAST_MODE |
Use faster if less optimal encodation or
other shortcuts if available (affects DATAMATRIX ,
MICROPDF417 , PDF417 , QRCODE and
UPNQR only). |
EXTRA_ESCAPE_MODE |
Process special symbology-specific escape
sequences (CODE128 only). |
The default mode is DATA_MODE
. (Note that this differs
from the default for the CLI and GUI, which is
UNICODE_MODE
.)
DATA_MODE
, UNICODE_MODE
and
GS1_MODE
are mutually exclusive, whereas
ESCAPE_MODE
, GS1PARENS_MODE
,
GS1NOCHECK_MODE
, HEIGHTPERROW_MODE
,
FAST_MODE
and EXTRA_ESCAPE_MODE
are optional.
So, for example, you can set
->input_mode = UNICODE_MODE | ESCAPE_MODE; my_symbol
or
->input_mode = GS1_MODE | GS1PARENS_MODE | GS1NOCHECK_MODE; my_symbol
whereas
->input_mode = DATA_MODE | GS1_MODE; my_symbol
is not valid.
Permissible escape sequences (ESCAPE_MODE
) are listed in
Table : Escape Sequences, and the
special Code 128-only EXTRA_ESCAPE_MODE
escape sequences
are given in 6.1.10.1 Standard
Code 128 (ISO 15417). An example of GS1PARENS_MODE
usage is given in section 6.1.10.3 GS1-128.
GS1NOCHECK_MODE
is for use with legacy systems that have
data that does not conform to the current GS1 standard. Printable ASCII
input is still checked for, as is the validity of GS1 data specified
without AIs (e.g. linear data for GS1 DataBar
Omnidirectional/Limited/etc.).
For HEIGHTPERROW_MODE
, see --heightperrow
in section 4.4 Adjusting Height. The
height
member should be set to the desired per-row value on
input (it will be set to the overall height on output).
FAST_MODE
causes a less optimal encodation scheme to be
used for Data Matrix, MicroPDF417 and PDF417. For QR Code and UPNQR, it
affects Zint’s automatic mask selection - see 6.6.3 QR Code (ISO 18004) for details.
For input data requiring multiple ECIs, the following functions may be used:
int ZBarcode_Encode_Segs(struct zint_symbol *symbol,
const struct zint_seg segs[], const int seg_count);
int ZBarcode_Encode_Segs_and_Print(struct zint_symbol *symbol,
const struct zint_seg segs[], const int seg_count, int rotate_angle);
int ZBarcode_Encode_Segs_and_Buffer(struct zint_symbol *symbol,
const struct zint_seg segs[], const int seg_count, int rotate_angle);
int ZBarcode_Encode_Segs_and_Buffer_Vector(struct zint_symbol *symbol,
const struct zint_seg segs[], const int seg_count, int rotate_angle);
These are direct analogues of the previously mentioned
ZBarcode_Encode()
,
ZBarcode_Encode_and_Print()
,
ZBarcode_Encode_and_Buffer()
and
ZBarcode_Encode_and_Buffer_Vector()
respectively, where
instead of a pair consisting of "source, length"
, a pair
consisting of "segs, seg_count"
is given, with
segs
being an array of struct zint_seg
segments and seg_count
being the number of elements it
contains. The zint_seg structure is of the form:
struct zint_seg {
unsigned char *source; /* Data to encode */
int length; /* Length of `source`. If 0, `source` must be
NUL-terminated */
int eci; /* Extended Channel Interpretation */
};
The symbology must support ECIs (see Table : ECI-Aware Symbologies). For example:
#include <zint.h>
int main(int argc, char **argv)
{
struct zint_seg segs[] = {
{ "Κείμενο", 0, 9 },
{ "Текст", 0, 7 },
{ "文章", 0, 20 }
};
struct zint_symbol *my_symbol;
= ZBarcode_Create();
my_symbol ->symbology = BARCODE_AZTEC;
my_symbol->input_mode = UNICODE_MODE;
my_symbol(my_symbol, segs, 3);
ZBarcode_Encode_Segs(my_symbol, 0);
ZBarcode_Print(my_symbol);
ZBarcode_Deletereturn 0;
}
A maximum of 256 segments may be specified. Use of multiple segments with GS1 data is not currently supported.
To help with scaling the output, the following three function are available:
float ZBarcode_Default_Xdim(int symbol_id);
float ZBarcode_Scale_From_XdimDp(int symbol_id, float x_dim_mm, float dpmm,
const char *filetype) {
float ZBarcode_XdimDP_From_Scale(int symbol_id, float scale,
float x_dim_mm_or_dpmm, const char *filetype);
The first ZBarcode_Default_Xdim()
returns the default
X-dimension suggested by Zint for symbology symbol_id
.
The second ZBarcode_Scale_From_XdimDp()
returns the
scale to use to output to a file of type filetype
with
X-dimension x_dim_mm
at dpmm
dots per mm. The
given X-dimension must be non-zero and less than or equal to 10mm,
however dpmm
may be zero and defaults to 12 dpmm, and
filetype
may be NULL or empty in which case a GIF filetype
is assumed. For raster output (BMP/GIF/PCX/PNG/TIF) the scale is rounded
to half-integer increments.
For example:
/* Royal Mail 4-State Customer Code */
->symbology = BARCODE_RM4SCC;
my_symbol->dpmm = 600.0f / 25.4f; /* 600 dpi */
my_symbol->scale = ZBarcode_Scale_From_XdimDp(
my_symbol->symbology,
my_symbol(my_symbol->symbology),
ZBarcode_Default_Xdim->dpmm, "PNG"); /* Returns 7.5 */ my_symbol
The third function ZBarcode_XdimDP_From_Scale()
is the
“reverse” of ZBarcode_Scale_From_XdimDp()
, returning the
X-dimension (in mm) or the dot density (in dpmm) given a scale
scale
. Both scale
and
x_dim_mm_or_dpmm
must be non-zero. The returned value is
bound to the maximum value of dpmm (1000), so must be further bound to
10 on return if the X-dimension is sought.
Note that the X-dimension to use is application dependent, and varies not only due to the symbology, resolution and filetype but also due to the type of scanner used, the intended scanning distance, and what media (“substrates”) the barcode appears on.
An additional function available in the API is:
int ZBarcode_ValidID(int symbol_id);
which allows you to check whether a given symbology is available, returning a non-zero value if so. For example:
if (ZBarcode_ValidID(BARCODE_PDF417) != 0) {
("PDF417 available\n");
printf} else {
("PDF417 not available\n");
printf}
Another function that may be useful is:
int ZBarcode_BarcodeName(int symbol_id, char name[32]);
which copies the name of a symbology into the supplied
name
buffer, which should be 32 characters in length. The
name is NUL
-terminated, and zero is returned on success.
For instance:
char name[32];
if (ZBarcode_BarcodeName(BARCODE_PDF417, name) == 0) {
("%s\n", name);
printf}
will print BARCODE_PDF417
.
It can be useful for frontend programs to know the capabilities of a symbology. This can be determined using another additional function:
unsigned int ZBarcode_Cap(int symbol_id, unsigned int cap_flag);
by OR
-ing the flags below in the cap_flag
argument and checking the return to see which are set.
Value | Meaning |
---|---|
ZINT_CAP_HRT |
Can the symbology print Human Readable Text? |
ZINT_CAP_STACKABLE |
Is the symbology stackable? |
ZINT_CAP_EANUPC 12 |
Is the symbology EAN/UPC? |
ZINT_CAP_COMPOSITE |
Does the symbology support composite data? (see 6.3 GS1 Composite Symbols (ISO 24723) below) |
ZINT_CAP_ECI |
Does the symbology support Extended Channel Interpretations? |
ZINT_CAP_GS1 |
Does the symbology support GS1 data? |
ZINT_CAP_DOTTY |
Can the symbology be outputted as dots? |
ZINT_CAP_QUIET_ZONES |
Does the symbology have default quiet zones? |
ZINT_CAP_FIXED_RATIO |
Does the symbology have a fixed width-to-height (aspect) ratio? |
ZINT_CAP_READER_INIT |
Does the symbology support Reader Initialisation? |
ZINT_CAP_FULL_MULTIBYTE |
Is the ZINT_FULL_MULTIBYTE
option applicable? |
ZINT_CAP_MASK |
Is mask selection applicable? |
ZINT_CAP_STRUCTAPP |
Does the symbology support Structured Append? |
ZINT_CAP_COMPLIANT_HEIGHT |
Does the symbology have a compliant height defined? |
For example:
unsigned int cap;
= ZBarcode_Cap(BARCODE_PDF417, ZINT_CAP_HRT | ZINT_CAP_ECI);
cap if (cap & ZINT_CAP_HRT) {
("PDF417 supports HRT\n");
printf} else {
("PDF417 does not support HRT\n");
printf}
if (cap & ZINT_CAP_ECI) {
("PDF417 supports ECI\n");
printf} else {
("PDF417 does not support ECI\n");
printf}
Whether the Zint library linked to was built with PNG support may be determined with:
int ZBarcode_NoPng();
which returns 1 if no PNG support is available, else zero.
Lastly, the version of the Zint library linked to is returned by:
int ZBarcode_Version();
The version parts are separated by hundreds. For instance, version
"2.9.1"
is returned as "20901"
.
One-dimensional or linear symbols are what most people associate with the term barcode. They consist of a number of bars and a number of spaces of differing widths.
Developed by Intermec in 1977, Code 11 is similar to Code 2 of 5
Matrix and is primarily used in telecommunications. The symbol can
encode data consisting of the digits 0-9 and the dash character
(-
) up to a maximum of 140 characters. Two modulo-11 check
digits are added by default. To add just one check digit, set
--vers=1
(API option_2 = 1
). To add no check
digits, set --vers=2
(API option_2 = 2
).
Code 2 of 5 is a family of one-dimensional symbols, 8 of which are supported by Zint. Note that the names given to these standards alters from one source to another so you should take care to ensure that you have the right barcode type before using these standards.
Also known as Code 2 of 5 Matrix, this is a self-checking code used
in industrial applications and photo development. Standard Code 2 of 5
will encode numeric input (digits 0-9) up to a maximum of 112 digits. No
check digit is added by default. To add a check digit, set
--vers=1
(API option_2 = 1
). To add a check
digit but not show it in the Human Readable Text, set
--vers=2
(API option_2 = 2
).
Used for baggage handling in the air-transport industry by the International Air Transport Agency, this self-checking code will encode numeric input (digits 0-9) up to a maximum of 80 digits. No check digit is added by default, but can be set the same as for 6.1.2.1 Standard Code 2 of 5.
Industrial Code 2 of 5 can encode numeric input (digits 0-9) up to a maximum of 79 digits. No check digit is added by default, but can be set the same as for 6.1.2.1 Standard Code 2 of 5.
This self-checking symbology encodes pairs of numbers, and so can only encode an even number of digits (0-9). If an odd number of digits is entered a leading zero is added by Zint. A maximum of 62 pairs (124 digits) can be encoded. No check digit is added by default, but can be set the same as for 6.1.2.1 Standard Code 2 of 5.
Data Logic does not include a check digit by default and can encode numeric input (digits 0-9) up to a maximum of 113 digits. Check digit options are the same as for 6.1.2.1 Standard Code 2 of 5.
ITF-14, also known as UPC Shipping Container Symbol or Case Code, is based on Interleaved Code 2 of 5 and requires a 13-digit numeric input (digits 0-9). One modulo-10 check digit is added by Zint.
If no border option is specified Zint defaults to adding a bounding
box with a border width of 5. This behaviour can be overridden by using
the --bind
option (API
output_options |= BARCODE_BIND
). Similarly the border width
can be overridden using --border
(API
border_width
). If a symbol with no border is required this
can be achieved by explicitly setting the border type to box (or bind or
bindtop) and leaving the border width 0.
Leitcode is based on Interleaved Code 2 of 5 and is used by Deutsche Post for routing purposes. Leitcode requires a 13-digit numerical input to which Zint adds a check digit.
Identcode is based on Interleaved Code 2 of 5 and is used by Deutsche Post for identification purposes. Identcode requires an 11-digit numerical input to which Zint adds a check digit.
UPC-A is used in the United States for retail applications. The symbol requires an 11-digit article number. The check digit is calculated by Zint. In addition EAN-2 and EAN-5 add-on symbols can be added using the + character. For example, to draw a UPC-A symbol with the data 72527270270 with an EAN-5 add-on showing the data 12345 use the command:
zint -b UPCA -d "72527270270+12345"
or using the API encode a data string with the + character included:
->symbology = BARCODE_UPCA;
my_symbol= ZBarcode_Encode_and_Print(my_symbol, "72527270270+12345", 0, 0); error
If your input data already includes the check digit symbology
BARCODE_UPCA_CHK
(35) can be used which takes a 12-digit
input and validates the check digit before encoding.
A quiet zone indicator can be added to the HRT by setting
--guardwhitespace
(API
output_options |= EANUPC_GUARD_WHITESPACE
). For UPC, this
is only relevant when there is add-on:
zint -b UPCA -d "72527270270+12345" --guardwhitespace
or using the API:
->symbology = BARCODE_UPCA;
my_symbol->output_options |= EANUPC_GUARD_WHITESPACE;
my_symbol= ZBarcode_Encode_and_Print(my_symbol, "72527270270+12345", 0, 0); error
You can adjust the gap between the main symbol and an add-on in
integral multiples of the X-dimension by setting --addongap
(API option_2
) to a value between 9 (default) and 12. The
height in X-dimensions that the guard bars descend below the main bars
can be adjusted by setting --guarddescent
(API
guard_descent
) to a value between 0 and 20 (default 5).
UPC-E is a zero-compressed version of UPC-A developed for smaller packages. The code requires a 6-digit article number (digits 0-9). The check digit is calculated by Zint. EAN-2 and EAN-5 add-on symbols can be added using the + character as with UPC-A. In addition Zint also supports Number System 1 encoding by entering a 7-digit article number starting with the digit 1. For example:
zint -b UPCE -d "1123456"
or
->symbology = BARCODE_UPCE;
my_symbol= ZBarcode_Encode_and_Print(my_symbol, "1123456", 0, 0); error
If your input data already includes the check digit symbology
BARCODE_UPCE_CHK
(38) can be used which takes a 7 or
8-digit input and validates the check digit before encoding.
As with UPC-A, a quiet zone indicator can be added when there is an
add-on by setting --guardwhitespace
(API
output_options |= EANUPC_GUARD_WHITESPACE
):
zint -b UPCE -d "1123456+12" --guardwhitespace
You can adjust the gap between the main symbol and an add-on in
integral multiples of the X-dimension by setting --addongap
(API option_2
) to a value between 7 (default) and 12. The
height in X-dimensions that the guard bars descend below the main bars
can be adjusted by setting --guarddescent
(API
guard_descent
) to a value between 0 and 20 (default 5).
The EAN system is used in retail across Europe and includes standards for EAN-2, EAN-5, EAN-8 and EAN-13 which encode 2, 5, 7 or 12-digit numbers respectively. Zint will decide which symbology to use depending on the length of the input data. In addition EAN-2 and EAN-5 add-on symbols can be added to EAN-8 and EAN-13 symbols using the + character as with UPC symbols. For example:
zint -b EANX -d "54321"
will encode a stand-alone EAN-5, whereas
zint -b EANX -d "7432365+54321"
will encode an EAN-8 symbol with an EAN-5 add-on. As before these results can be achieved using the API:
->symbology = BARCODE_EANX;
my_symbol
= ZBarcode_Encode_and_Print(my_symbol, "54321", 0, 0);
error
= ZBarcode_Encode_and_Print(my_symbol, "7432365+54321", 0, 0); error
All of the EAN symbols include check digits which are added by Zint.
If you are encoding an EAN-8 or EAN-13 symbol and your data already
includes the check digit then you can use symbology
BARCODE_EANX_CHK
(14) which takes an 8 or 13-digit input
and validates the check digit before encoding.
Options to add quiet zone indicators and to adjust the add-on gap and the guard bar descent height are the same as for 6.1.3.2 UPC Version E. For instance:
zint -b EANX_CHK -d "74323654" --guardwhitespace
EAN-13 symbols (also known as Bookland EAN-13) can also be produced from 9-digit SBN, 10-digit ISBN or 13-digit ISBN-13 data. The relevant check digit needs to be present in the input data and will be verified before the symbol is generated.
As with EAN-13, a quiet zone indicator can be added using
--guardwhitespace
:
EAN-2 and EAN-5 add-on symbols can be added using the + character, and there are options to adjust the add-on gap and the guard bar descent height - see 6.1.3.2 UPC Version E.
Also known as Plessey Code, this symbology was developed by the Plessey Company Ltd. in the UK. The symbol can encode data consisting of digits (0-9) or letters A-F up to a maximum of 67 characters and includes a hidden CRC check digit.
Based on Plessey and developed by MSI Data Corporation, MSI Plessey
can encode numeric (digits 0-9) input of up to 92 digits. It has a range
of check digit options that are selectable by setting
--vers
(API option_2
), shown in the table
below:
Value | Check Digits |
---|---|
0 | None |
1 | Modulo-10 (Luhn) |
2 | Modulo-10 & Modulo-10 |
3 | Modulo-11 (IBM) |
4 | Modulo-11 (IBM) & Modulo-10 |
5 | Modulo-11 (NCR) |
6 | Modulo-11 (NCR) & Modulo-10 |
To not show the check digit or digits in the Human Readable Text, add
10 to the --vers
value. For example --vers=12
(API option_2 = 12
) will add two hidden modulo-10 check
digits.
Telepen Alpha was developed by SB Electronic Systems Limited and can encode ASCII text input, up to a maximum of 69 characters. Telepen includes a hidden modulo-127 check digit, added by Zint.
Telepen Numeric allows compression of numeric data into a Telepen
symbol. Data can consist of pairs of numbers or pairs consisting of a
numerical digit followed an X character. For example: 466333 and 466X33
are valid codes whereas 46X333 is not (the digit pair "X3"
is not valid). Up to 136 digits can be encoded. Telepen Numeric includes
a hidden modulo-127 check digit which is added by Zint.
Standard Code 39 was developed in 1974 by Intermec. Input data can be
up to 86 characters in length and can include the characters 0-9, A-Z,
dash (-
), full stop (.
), space, asterisk
(*
), dollar ($
), slash (/
), plus
(+
) and percent (%
). The standard does not
require a check digit but a modulo-43 check digit can be added if
desired by setting --vers=1
(API
option_2 = 1
). To add a check digit but not show it in the
Human Readable Text, set --vers=2
(API
option_2 = 2
).
Also known as Code 39e and Code39+, this symbology expands on Standard Code 39 to provide support for the full 7-bit ASCII character set. The check digit options are the same as for 6.1.7.1 Standard Code 39 (ISO 16388).
A variation of Extended Code 39, Code 93 also supports full ASCII
text, accepting up to 123 characters. Two check characters are added by
Zint. By default these check characters are not shown in the Human
Readable Text, but may be shown by setting --vers=1
(API
option_2 = 1
).
PZN is a Code 39 based symbology used by the pharmaceutical industry in Germany. PZN encodes a 7-digit number to which Zint will add a modulo-11 check digit (PZN8). Input less than 7 digits will be zero-filled. An 8-digit input can be supplied in which case Zint will validate the check digit.
To encode a PZN7 (obsolete since 2013) instead set
--vers=1
(API option_2 = 1
) and supply up to 7
digits. As with PZN8, a modulo-11 check digit will be added or if 7
digits supplied the check digit validated.
LOGMARS (Logistics Applications of Automated Marking and Reading Symbols) is a variation of the Code 39 symbology used by the U.S. Department of Defense. LOGMARS encodes the same character set as 6.1.7.1 Standard Code 39 (ISO 16388), and the check digit options are also the same. Input is restricted to a maximum of 30 characters.
A variation of Code 39 used by the Italian Ministry of Health (“Ministero della Sanità”) for encoding identifiers on pharmaceutical products. This symbology requires a numeric input up to 8 digits in length. A check digit is added by Zint.
This variant adds a leading '+'
character and a trailing
modulo-49 check digit to a standard Code 39 symbol as required by the
Health Industry Barcode standards.
A variation of Code 39 that for vehicle identification numbers used
in North America (first character '1'
to '5'
)
has a check character verification stage. A 17 character input (0-9, and
A-Z excluding 'I'
, 'O'
and 'Q'
)
is required. An invisible Import character prefix 'I'
can
be added by setting --vers=1
(API
option_2 = 1
).
Also known as NW-7, Monarch, ABC Codabar, USD-4, Ames Code and Code
27, this symbology was developed in 1972 by Monarch Marketing Systems
for retail purposes. The American Blood Commission adopted Codabar in
1977 as the standard symbology for blood identification. Codabar can
encode up to 103 characters starting and ending with the letters A-D and
containing between these letters the numbers 0-9, dash (-
),
dollar ($
), colon (:
), slash (/
),
full stop (.
) or plus (+
). No check character
is generated by default, but a modulo-16 one can be added by setting
--vers=1
(API option_2 = 1
). To have the check
character appear in the Human Readable Text, set --vers=2
(API option_2 = 2
).
Developed by Laetus, Pharmacode is used for the identification of pharmaceuticals. The symbology is able to encode whole numbers between 3 and 131070.
One of the most ubiquitous one-dimensional barcode symbologies, Code 128 was developed in 1981 by Computer Identics. This symbology supports full ASCII text and uses a three-Code Set system to compress the data into a smaller symbol. Zint automatically switches between Code Sets A, B and C (but see following) and adds a hidden modulo-103 check digit.
Manual switching of Code Sets is possible using the
--extraesc
option (API
input_mode |= EXTRA_ESCAPE_MODE
) and the Code 128-specific
escapes \^A
, \^B
, \^C
. For
instance the following will force switching to Code Set B for the data
"5678"
(normally Code Set C would be used throughout):
zint -b CODE128 -d "1234\^B5678" --extraesc
The manually selected Code Set will apply until the next Code Set
escape sequence, with the exception that data that cannot be represented
in that Code Set will be switched as appropriate. If the data contains a
special code sequence, it can be escaped by doubling the caret
(^
). For instance
zint -b CODE128 -d "\^AABC\^^BDEF" --extraesc
will encode the data "ABC\^BDEF"
in Code Set A.
Code 128 is the default barcode symbology used by Zint. In addition Zint supports the encoding of ISO/IEC 8859-1 (non-English) characters in Code 128 symbols. The ISO/IEC 8859-1 character set is shown in Annex A.2 Latin Alphabet No. 1 (ISO/IEC 8859-1).
Zint can encode a maximum of 99 symbol characters, which allows for e.g. 198 all-numeric characters.
It is sometimes advantageous to stop Code 128 from using Code Set C
which compresses numerical data. The BARCODE_CODE128AB
13 variant (symbology 60) suppresses
Code Set C in favour of Code Sets A and B.
Note that the special escapes to manually switch Code Sets mentioned above are not available for this variant (nor for any other).
A variation of Code 128 previously known as UCC/EAN-128, this symbology is defined by the GS1 General Specifications. Application Identifiers (AIs) should be entered using [square bracket] notation. These will be converted to parentheses (round brackets) for the Human Readable Text. This will allow round brackets to be used in the data strings to be encoded.
For compatibility with data entry in other systems, if the data does
not include round brackets, the option --gs1parens
(API
input_mode |= GS1PARENS_MODE
) may be used to signal that
AIs are encased in round brackets instead of square ones.
Fixed length data should be entered at the appropriate length for correct encoding. GS1-128 does not support extended ASCII (ISO/IEC 8859-1) characters. Check digits for GTIN data AI (01) are not generated and need to be included in the input data. The following is an example of a valid GS1-128 input:
zint -b 16 -d "[01]98898765432106[3202]012345[15]991231"
or using the --gs1parens
option:
zint -b 16 --gs1parens -d "(01)98898765432106(3202)012345(15)991231"
A shorter version of GS1-128 which encodes GTIN data only. A 13-digit number is required. The GTIN check digit and AI (01) are added by Zint.
A variation of Code 128 the ‘Nummer der Versandeinheit’ standard, also known as SSCC-18 (Serial Shipping Container Code), includes both a visible modulo-10 and a hidden modulo-103 check digit. NVE-18 requires a 17-digit numerical input. Check digits and AI (00) are added by Zint.
This option adds a leading '+'
character and a trailing
modulo-49 check digit to a standard Code 128 symbol as required by the
Health Industry Barcode standards.
Another variation of Code 128 as used by DPD (Deutscher Paketdienst).
Requires a 27 or 28 character input. For 28 character input, the first
character is an identification tag (Barcode ID), which should usually be
"%"
(ASCII 37). If 27 characters are supplied,
"%"
will be prefixed by Zint (except if marked as a
“relabel”, see below). The rest of the 27-character input must be
alphanumeric, and is of the form:
Destination Post Code | Tracking Number | Service Code | Destination Country Code |
---|---|---|---|
PPPPPPP (7 alphanumerics) | TTTTTTTTTTTTTT (14 alphanumerics) | SSS (3 digits) | CCC (3-digit ISO 3166-1) |
A warning will be generated if the Service Code, the Destination Country Code, or the last 10 characters of the Tracking Number are non-numeric.
Zint formats the Human Readable Text as specified by DPD, leaving out the identication tag, and adds a modulo-36 check character to the text (not to the barcode itself), thus:
PPPP PPP TTTT TTTT TTTT TT SSS CCC D
By default a top boundary bar is added, with default width 3X. The
width can be overridden using --border
(API
border_width
). For a symbol with no top boundary bar,
explicitly set the border type to bindtop (or bind or box) and leave the
border width 0.
A DPD Code can be marked as a “relabel” by specifying
--vers=1
(API option_2 = 1
), which omits the
identification tag and prints the barcode at half height. In this case,
an input of 27 alphanumeric characters is required.
The Universal Postal Union S10 variant of Code 128 encodes 13
characters in the format "SSNNNNNNNNXCC"
, where
"SS"
is a two-character alphabetic service indicator,
"NNNNNNNN"
is an 8-digit serial number, "X"
is
a modulo-11 check digit, and "CC"
is a two-character ISO
3166-1 country code.
The check digit may be omitted in which case Zint will add it. Warnings will be generated if the service indicator is non-standard or the country code is not ISO 3361-1.
Previously known as RSS (Reduced Spaced Symbology), these symbols are
due to replace GS1-128 symbols in accordance with the GS1 General
Specifications. If a GS1 DataBar symbol is to be printed with a 2D
component as specified in ISO/IEC 24723 set --mode=2
(API
option_1 = 2
). See 6.3 GS1 Composite Symbols (ISO
24723) to find out how to generate DataBar symbols with 2D
components.
Previously known as RSS-14 this standard encodes a 13-digit item code. A check digit and Application Identifier of (01) are added by Zint. (A 14-digit code that appends the check digit may be given, in which case the check digit will be verified.)
GS1 DataBar Omnidirectional symbols should have a height of 33 or greater. To produce a GS1 DataBar Truncated symbol set the symbol height to a value between 13 and 32. Truncated symbols may not be scannable by omnidirectional scanners.
Previously known as RSS Limited this standard encodes a 13-digit item code and can be used in the same way as GS1 DataBar Omnidirectional above. GS1 DataBar Limited, however, is limited to data starting with digits 0 and 1 (i.e. numbers in the range 0 to 1999999999999). As with GS1 DataBar Omnidirectional a check digit and Application Identifier of (01) are added by Zint, and a 14-digit code may be given in which case the check digit will be verified.
Previously known as RSS Expanded this is a variable length symbology
capable of encoding data from a number of AIs in a single symbol. AIs
should be encased in [square brackets] in the input data, which will be
converted to parentheses (round brackets) before being included in the
Human Readable Text attached to the symbol. This method allows the
inclusion of parentheses in the data to be encoded. If the data does not
include parentheses, the AIs may alternatively be encased in parentheses
using the --gs1parens
switch. See 6.1.10.3 GS1-128.
GTIN data AI (01) should also include the check digit data as this is not calculated by Zint when this symbology is encoded. Fixed length data should be entered at the appropriate length for correct encoding. The following is an example of a valid GS1 DataBar Expanded input:
zint -b 31 -d "[01]98898765432106[3202]012345[15]991231"
The Korean Postal Barcode is used to encode a 6-digit number and includes one check digit.
A highly compressed symbol for numeric data. The number of channels
in the symbol can be between 3 and 8 and this can be specified by
setting the value of the --vers
option (API
option_2
). It can also be determined by the length of the
input data: e.g. a three character input string generates a 4 channel
code by default.
The maximum values permitted depend on the number of channels used as shown in the table below:
Channels | Minimum Value | Maximum Value |
---|---|---|
3 | 00 | 26 |
4 | 000 | 292 |
5 | 0000 | 3493 |
6 | 00000 | 44072 |
7 | 000000 | 576688 |
8 | 0000000 | 7742862 |
Designed by IBM for marking silicon wafers, each BC412 character is
represented by 4 bars of a single size, interleaved with 4 spaces of
varying sizes that total 8 (hence 4 bars in 12). Zint implements the
SEMI T1-95 standard, where input must be alphanumeric, excluding the
letter O
, and must be from 7 to 18 characters in length. A
single check character is added by Zint, appearing in the 2nd character
position. Lowercase input is automatically made uppercase.
An early innovation to get more information into a symbol, used primarily in the vehicle industry, is to simply stack one-dimensional codes on top of each other. This can be achieved at the command prompt by giving more than one set of input data. For example
zint -d "This" -d "That"
will draw two Code 128 symbols, one on top of the other. The same
result can be achieved using the API by executing the
ZBarcode_Encode()
function more than once on a symbol. For
example:
->symbology = BARCODE_CODE128;
my_symbol
= ZBarcode_Encode(my_symbol, "This", 0);
error
= ZBarcode_Encode(my_symbol, "That", 0);
error
= ZBarcode_Print(my_symbol); error
Note that the Human Readable Text will be that of the last data, so
it’s best to use the option --notext
(API
show_hrt = 0
).
The stacked barcode rows can be separated by row separator bars by
specifying --bind
(API
output_options |= BARCODE_BIND
). The height of the row
separator bars in integral multiples of the X-dimension (minimum and
default 1, maximum 4) can be set by --separator
(API
option_3
):
zint --bind --notext --separator=2 -d "This" -d "That"
A more sophisticated method is to use some type of line indexing which indicates to the barcode reader which order the stacked symbols should be read in. This is demonstrated by the symbologies below.
This is a stacked symbology based on Code 128 which can encode
Latin-1 data up to a maximum length of 2725 characters. The width of the
Codablock-F symbol can be set using the --cols
option (API
option_2
), to a value between 9 and 67. The height (number
of rows) can be set using the --rows
option (API
option_1
), with a maximum of 44. Zint does not currently
support encoding of GS1 data in Codablock-F symbols.
A separate symbology ID (BARCODE_HIBC_BLOCKF
) can be
used to encode Health Industry Barcode (HIBC) data which adds a leading
'+'
character and a modulo-49 check digit to the encoded
data.
Code 16K uses a Code 128 based system which can stack up to 16 rows
in a block. This gives a maximum data capacity of 77 characters or 154
numerical digits and includes two modulo-107 check digits. Code 16K also
supports ISO/IEC 8859-1 character encoding in the same manner as Code
128. GS1 data encoding is also supported. The minimum number of rows to
use can be set using the --rows
option (API
option_1
), with values from 2 to 16.
Heavily used in the parcel industry, the PDF417 symbology can encode a vast amount of data into a small space. Zint supports encoding up to the ISO standard maximum symbol size of 925 codewords which (at error correction level 0) allows a maximum data size of 1850 text characters, or 2710 digits.
The width of the generated PDF417 symbol can be specified at the
command line using the --cols
switch (API
option_2
) followed by a number between 1 and 30, the number
of rows using the --rows
switch (API option_3
)
followed by a number between 3 and 90, and the amount of error
correction information can be specified by using the
--secure
switch (API option_1
) followed by a
number between 0 and 8 where the number of codewords used for error
correction is determined by 2^(value + 1)
. The default
level of error correction is determined by the amount of data being
encoded.
This symbology uses Latin-1 character encoding by default but also
supports the ECI encoding mechanism. A separate symbology ID
(BARCODE_HIBC_PDF
) can be used to encode Health Industry
Barcode (HIBC) data.
For a faster but less optimal encoding, the --fast
option (API input_mode |= FAST_MODE
) may be used.
PDF417 supports Structured Append of up to 99,999 symbols and an
optional numeric ID of up to 30 digits, which can be set by using the
--structapp
option (see 4.17
Structured Append) (API structapp
). The ID consists of
up to 10 triplets, each ranging from "000"
to
"899"
. For instance "123456789"
would be a
valid ID of 3 triplets. However "123456900"
would not, as
the last triplet "900"
exceeds "899"
. The
triplets are 0-filled, for instance "1234"
becomes
"123004"
. If an ID is not given, no ID is encoded.
Previously known as Truncated PDF417, Compact PDF417 omits some per-row overhead to produce a narrower but less robust symbol. Options are the same as for PDF417 above.
A variation of the PDF417 standard, MicroPDF417 is intended for
applications where symbol size needs to be kept to a minimum. 34
predefined symbol sizes are available with 1 - 4 columns and 4 - 44
rows. The maximum amount a MicroPDF417 symbol can hold is 250
alphanumeric characters or 366 digits. The amount of error correction
used is dependent on symbol size. The number of columns used can be
determined using the --cols
switch (API
option_2
) as with PDF417.
This symbology uses Latin-1 character encoding by default but also
supports the ECI encoding mechanism. A separate symbology ID
(BARCODE_HIBC_MICPDF
) can be used to encode Health Industry
Barcode (HIBC) data. MicroPDF417 supports FAST_MODE
and
Structured Append the same as PDF417, for which see details.
A stacked variation of the GS1 DataBar Truncated symbol requiring the same input (see 6.1.11.1 GS1 DataBar Omnidirectional and GS1 DataBar Truncated), this symbol is the same as the following GS1 DataBar Stacked Omnidirectional symbol except that its height is reduced and its central separator is a single row, making it suitable for small items when omnidirectional scanning is not required. It can be generated with a two-dimensional component to make a composite symbol.
A stacked variation of the GS1 DataBar Omnidirectional symbol requiring the same input (see 6.1.11.1 GS1 DataBar Omnidirectional and GS1 DataBar Truncated). The data is encoded in two rows of bars with a central 3-row separator. This symbol can be generated with a two-dimensional component to make a composite symbol.
A stacked variation of the GS1 DataBar Expanded symbol for smaller
packages. Input is the same as for GS1 DataBar Expanded (see 6.1.11.3 GS1 DataBar Expanded). In
addition the width of the symbol can be altered using the
--cols
switch (API option_2
). In this case the
number of columns (values 1 to 11) relates to the number of character
pairs on each row of the symbol. Alternatively the --rows
switch (API option_3
) can be used to specify the maximum
number of rows (values 2 to 11), and the number of columns will be
adjusted accordingly. This symbol can be generated with a
two-dimensional component to make a composite symbol. For symbols with a
2D component the number of columns must be at least 2.
Developed in 1987 at Intermec, Code 49 is a cross between UPC and
Code 39. It is one of the earliest stacked symbologies and influenced
the design of Code 16K a few years later. It supports full 7-bit ASCII
input up to a maximum of 49 characters or 81 numeric digits. GS1 data
encoding is also supported. The minimum number of rows to use can be set
using the --rows
option (API option_1
), with
values from 2 to 8.
GS1 Composite symbols employ a mixture of components to give more
comprehensive information about a product. The permissible contents of a
composite symbol is determined by the terms of the GS1 General
Specifications. Composite symbols consist of a linear component which
can be an EAN, UPC, GS1-128 or GS1 DataBar symbol, a two-dimensional
(2D) component which is based on PDF417 or MicroPDF417, and a separator
pattern. The type of linear component to be used is determined using the
-b
or --barcode
switch (API
symbology
) as with other encoding methods. Valid values are
shown below.
Numeric Value | Name | Barcode Name |
---|---|---|
130 | BARCODE_EANX_CC |
GS1 Composite Symbol with EAN linear component |
131 | BARCODE_GS1_128_CC |
GS1 Composite Symbol with GS1-128 linear component |
132 | BARCODE_DBAR_OMN_CC |
GS1 Composite Symbol with GS1 DataBar Omnidirectional linear component |
133 | BARCODE_DBAR_LTD_CC |
GS1 Composite Symbol with GS1 DataBar Limited linear component |
134 | BARCODE_DBAR_EXP_CC |
GS1 Composite Symbol with GS1 DataBar Expanded linear component |
135 | BARCODE_UPCA_CC |
GS1 Composite Symbol with UPC-A linear component |
136 | BARCODE_UPCE_CC |
GS1 Composite Symbol with UPC-E linear component |
137 | BARCODE_DBAR_STK_CC |
GS1 Composite Symbol with GS1 DataBar Stacked component |
138 | BARCODE_DBAR_OMNSTK_CC |
GS1 Composite Symbol with GS1 DataBar Stacked Omnidirectional component |
139 | BARCODE_DBAR_EXPSTK_CC |
GS1 Composite Symbol with GS1 DataBar Expanded Stacked component |
The data to be encoded in the linear component of a composite symbol
should be entered into a primary string with the data for the 2D
component being entered in the normal way. To do this at the command
prompt use the --primary
switch (API primary
).
For example:
zint -b EANX_CC --mode=1 --primary=331234567890 -d "[99]1234-abcd"
This creates an EAN-13 linear component with the data
"331234567890"
and a 2D CC-A (see below) component with the data
"(99)1234-abcd"
. The same results can be achieved using the
API as shown below:
->symbology = BARCODE_EANX_CC;
my_symbol
->option_1 = 1;
my_symbol
(my_symbol->primary, "331234567890");
strcpy
(my_symbol, "[99]1234-abcd", 0, 0); ZBarcode_Encode_and_Print
EAN-2 and EAN-5 add-on data can be used with EAN and UPC symbols using the + symbol as described in sections 6.1.3 UPC (Universal Product Code) (ISO 15420) and 6.1.4 EAN (European Article Number) (ISO 15420).
The 2D component of a composite symbol can use one of three systems:
CC-A, CC-B and CC-C, as described below. The 2D component type can be
selected automatically by Zint dependent on the length of the input
string. Alternatively the three methods can be accessed using the
--mode
prompt (API option_1
) followed by 1, 2
or 3 for CC-A, CC-B or CC-C respectively.
This system uses a variation of MicroPDF417 which is optimised to fit
into a small space. The size of the 2D component and the amount of error
correction is determined by the amount of data to be encoded and the
type of linear component which is being used. CC-A can encode up to 56
numeric digits or an alphanumeric string of shorter length. To select
CC-A use --mode=1
(API option_1 = 1
).
This system uses MicroPDF417 to encode the 2D component. The size of
the 2D component and the amount of error correction is determined by the
amount of data to be encoded and the type of linear component which is
being used. CC-B can encode up to 338 numeric digits or an alphanumeric
string of shorter length. To select CC-B use --mode=2
(API
option_1 = 2
).
This system uses PDF417 and can only be used in conjunction with a
GS1-128 linear component. CC-C can encode up to 2361 numeric digits or
an alphanumeric string of shorter length. To select CC-C use
--mode=3
(API option_1 = 3
).
Developed by Laetus, Pharmacode Two-Track is an alternative system to Pharmacode One-Track (see 6.1.9 Pharmacode) used for the identification of pharmaceuticals. The symbology is able to encode whole numbers between 4 and 64570080.
Used by the United States Postal Service until 2009, the POSTNET
barcode was used for encoding zip-codes on mail items. POSTNET uses
numerical input data and includes a modulo-10 check digit. While Zint
will encode POSTNET symbols of up to 38 digits in length, standard
lengths as used by USPS were PostNet6
(5-digit ZIP input),
PostNet10
(5-digit ZIP + 4-digit user data) and
PostNet12
(5-digit ZIP + 6-digit user data), and a warning
will be issued if the input length is not one of these.
Used by the United States Postal Service until 2009, the PLANET
(Postal Alpha Numeric Encoding Technique) barcode was used for encoding
routing data on mail items. PLANET uses numerical input data and
includes a modulo-10 check digit. While Zint will encode PLANET symbols
of up to 38 digits in length, standard lengths used by USPS were
Planet12
(11-digit input) and Planet14
(13-digit input), and as with POSTNET a warning will be issued if the
length is not one of these.
Based on POSTNET, the CEPNet symbol is used by Correios, the Brazilian postal service, to encode CEP (Código de Endereçamento Postal) numbers on mail items. Input should consist of eight digits with the check digit being automatically added by Zint.
Australia Post Standard Customer Barcode, Customer Barcode 2 and Customer Barcode 3 are 37-bar, 52-bar and 67-bar specifications respectively, developed by Australia Post for printing Delivery Point ID (DPID) and customer information on mail items. Valid data characters are 0-9, A-Z, a-z, space and hash (#). A Format Control Code (FCC) is added by Zint and should not be included in the input data. Reed-Solomon error correction data is generated by Zint. Encoding behaviour is determined by the length of the input data according to the formula shown in the following table.
Input Length | Required Input Format | Symbol Length | FCC | Encoding Table |
---|---|---|---|---|
8 | 99999999 |
37-bar | 11 | None |
13 | 99999999AAAAA |
52-bar | 59 | C |
16 | 9999999999999999 |
52-bar | 59 | N |
18 | 99999999AAAAAAAAAA |
67-bar | 62 | C |
23 | 99999999999999999999999 |
67-bar | 62 | N |
A Reply Paid version of the Australia Post 4-State Barcode (FCC 45) which requires an 8-digit DPID input.
A Routing version of the Australia Post 4-State Barcode (FCC 87) which requires an 8-digit DPID input.
A Redirection version of the Australia Post 4-State Barcode (FCC 92) which requires an 8-digit DPID input.
This symbology is used by Royal Dutch TPG Post (Netherlands) for Postal code and automatic mail sorting. Data input can consist of numbers 0-9 and letters A-Z and needs to be 11 characters in length. No check digit is included.
The RM4SCC standard is used by the Royal Mail in the UK to encode
postcode and customer data on mail items. Data input can consist of
numbers 0-9 and letters A-Z and usually includes delivery postcode
followed by house number. For example "W1J0TR01"
for 1
Piccadilly Circus in London. Check digit data is generated by Zint.
Developed in 2014 as a replacement for RM4SCC this 4-state symbol includes Reed- Solomon error correction. Input is a pre-formatted alphanumeric string of 22 (for Barcode C) or 26 (for Barcode L) characters, producing a symbol with 66 or 78 bars respectively. The rules for the input data are complex, as summarized in the following table.
Format | Version ID | Class | Supply Chain ID | Item ID | Destination+DPS |
---|---|---|---|---|---|
1 digit (0-4) | 1 digit (0-3) | 1 alphanum. (0-9A-E) | 2 digits (C) or 6 digits (L) | 8 digits | 9 alphanumerics (1 of 6 patterns) |
The 6 Destination+DPS (Destination Post Code plus Delivery Point Suffix) patterns are:
FNFNLLNLS |
FFNNLLNLS |
FFNNNLLNL |
FFNFNLLNL |
FNNLLNLSS |
FNNNLLNLS |
where 'F'
stands for full alphabetic (A-Z),
'L'
for limited alphabetic (A-Z less
'CIKMOV'
), 'N'
for numeric (0-9), and
'S'
for space.
Four of the permitted patterns include a number of trailing space characters - these will be appended by Zint if not included in the input data.
For the two-dimensional Data Matrix-based version, see 6.6.2 Royal Mail 2D Mailmark (CMDM) (Data Matrix).
Also known as the OneCode barcode and used in the U.S. by the United
States Postal Service (USPS), the Intelligent Mail system replaced the
POSTNET and PLANET symbologies in 2009. Intelligent Mail is a fixed
length (65-bar) symbol which combines routing and customer information
in a single symbol. Input data consists of a 20-digit tracking code,
followed by a dash (-
), followed by a delivery point
zip-code which can be 0, 5, 9 or 11 digits in length. For example all of
the following inputs are valid data entries:
"01234567094987654321"
"01234567094987654321-01234"
"01234567094987654321-012345678"
"01234567094987654321-01234567891"
Used for address data on mail items for Japan Post. Accepted values
are 0-9, A-Z and dash (-
). A modulo 19 check digit is added
by Zint.
This is a method for creating 4-state codes where the data encoding
is provided by an external program. Input data should consist of the
letters 'D'
, 'A'
, 'F'
and
'T'
where these refer to descender, ascender, full
(ascender and descender) and tracker (neither ascender nor descender)
respectively. All other characters are invalid. The ratio of the tracker
size to full height can be given in thousandths (permille) using the
--vers
option (API option_2
). The default
value is 250 (25%).
For example the following
zint -b DAFT -d AAFDTTDAFADTFTTFFFDATFTADTTFFTDAFAFDTF --height=8.494 --vers=256
produces the same barcode (see 6.5.3 Royal Mail 4-State Customer Code (RM4SCC)) as
zint -b RM4SCC --compliantheight -d "W1J0TR01"
Also known as Semacode this symbology was developed in 1989 by Acuity
CiMatrix in partnership with the U.S. DoD and NASA. The symbol can
encode a large amount of data in a small area. Data Matrix encodes
characters in the Latin-1 set by default but also supports encoding in
other character sets using the ECI mechanism. It can also encode GS1
data. The size of the generated symbol can be adjusted using the
--vers
option (API option_2
) as shown in the
table below. A separate symbology ID (BARCODE_HIBC_DM
) can
be used to encode Health Industry Barcode (HIBC) data. Note that only
ECC200 encoding is supported, the older standards have now been removed
from Zint.
Input | Symbol Size | Input | Symbol Size | Input | Symbol Size | ||
---|---|---|---|---|---|---|---|
1 | 10 x 10 | 11 | 36 x 36 | 21 | 104 x 104 | ||
2 | 12 x 12 | 12 | 40 x 40 | 22 | 120 x 120 | ||
3 | 14 x 14 | 13 | 44 x 44 | 23 | 132 x 132 | ||
4 | 16 x 16 | 14 | 48 x 48 | 24 | 144 x 144 | ||
5 | 18 x 18 | 15 | 52 x 52 | 25 | 8 x 18 | ||
6 | 20 x 20 | 16 | 64 x 64 | 26 | 8 x 32 | ||
7 | 22 x 22 | 17 | 72 x 72 | 28 | 12 x 26 | ||
8 | 24 x 24 | 18 | 80 x 80 | 28 | 12 x 36 | ||
9 | 26 x 26 | 19 | 88 x 88 | 29 | 16 x 36 | ||
10 | 32 x 32 | 20 | 96 x 96 | 30 | 16 x 48 |
When using automatic symbol sizes you can force Zint to use square
symbols (versions 1-24) at the command line by using the option
--square
(API option_3 = DM_SQUARE
).
Data Matrix Rectangular Extension (ISO/IEC 21471) codes may be generated with the following values as before:
Input | Symbol Size | Input | Symbol Size | |
---|---|---|---|---|
31 | 8 x 48 | 40 | 20 x 36 | |
32 | 8 x 64 | 41 | 20 x 44 | |
33 | 8 x 80 | 42 | 20 x 64 | |
34 | 8 x 96 | 43 | 22 x 48 | |
35 | 8 x 120 | 44 | 24 x 48 | |
36 | 8 x 144 | 45 | 24 x 64 | |
37 | 12 x 64 | 46 | 26 x 40 | |
38 | 12 x 88 | 47 | 26 x 48 | |
39 | 16 x 64 | 48 | 26 x 64 |
DMRE symbol sizes may be activated in automatic size mode using the
option --dmre
(API option_3 = DM_DMRE
).
GS1 data may be encoded using FNC1 (default) or GS (Group Separator,
ASCII 29) as separator. Use the option --gssep
to change to
GS (API output_options |= GS1_GS_SEPARATOR
).
By default Zint uses a “de facto” codeword placement for symbols of
size 144 x 144 (version 24). To override this and use the now clarified
ISO/IEC standard placement, use option --dmiso144
(API
option_3 |= DM_ISO_144
).
For a faster but less optimal encoding, the --fast
option (API input_mode |= FAST_MODE
) may be used.
Data Matrix supports Structured Append of up to 16 symbols and a
numeric ID (file identifications), which can be set by using the
--structapp
option (see 4.17
Structured Append) (API structapp
). The ID consists of
2 numbers ID1
and ID2
, each of which can range
from 1 to 254, and is specified as the single number
ID1 * 1000 + ID2
, so for instance ID1
"123"
and ID2
"234"
would be
given as "123234"
. Note that both ID1
and
ID2
must be non-zero, so e.g. "123000"
or
"000123"
would be invalid IDs. If an ID is not given it
defaults to "001001"
.
This variant of Data Matrix, also known as “Complex Mail Data Mark” (CMDM), was introduced by Royal Mail along with 6.5.4 Royal Mail 4-State Mailmark, and offers space for customer data following an initial pre-formatted 45 character section, as summarized below.
Field Name | Length | Values |
---|---|---|
UPU Country ID | 4 | "JGB " |
Information Type | 1 | Alphanumeric |
Version ID | 1 | "1" |
Class | 1 | Alphanumeric |
Supply Chain ID | 7 | Numeric |
Item ID | 8 | Numeric |
Destination+DPS | 9 | Alphanumeric (1 of 6 patterns) |
Service Type | 1 | Numeric |
RTS Post Code | 7 | Alphanumeric (1 of 6 patterns) |
Reserved | 6 | Spaces |
Customer Data | 6, 45 or 29 | Anything (Latin-1) |
The 6 Destination+DPS (Destination Post Code plus Delivery Point
Suffix) patterns are the same as for the 4-state - see Table : Royal Mail Mailmark
Destination+DPS Patterns. The 6 RTS (Return to Sender) Post Code
patterns are the same also except without the additional DPS
'NL'
, i.e.
FNFNLLS |
FFNNLLS |
FFNNNLL |
FFNFNLL |
FNNLLSS |
FNNNLLS |
where 'F'
is full alphabetic (A-Z), 'L'
limited alphabetic (A-Z less 'CIKMOV'
), 'N'
numeric (0-9), and 'S'
space.
Three sizes are defined, one rectangular, with varying maximum amounts of optional customer data:
Name | Size | Customer Data | Zint Version |
---|---|---|---|
Type 7 | 24 x 24 | 6 characters | 8 |
Type 9 | 32 x 32 | 45 characters | 10 |
Type 29 | 16 x 48 | 29 characters | 30 |
Zint will automatically select a size based on the amount of customer
data, or it can be specified using the --vers
option (API
option_2
), which takes the Zint version number (one more
than the Royal Mail Type number). Zint will prefix the input data with
"JGB "
if it’s missing, and also space-pad the input if the
customer data is absent or falls short. As with Data Matrix, the
rectangular symbol Type 29 can be excluded from automatic size selection
by using the option --square
(API
option_3 = DM_SQUARE
).
GS1 data, the ECI mechanism, and Structured Append are not supported.
Also known as Quick Response Code this symbology was developed by
Denso. Four levels of error correction are available using the
--secure
option (API option_1
) as shown in the
following table.
Input | ECC Level | Error Correction Capacity | Recovery Capacity |
---|---|---|---|
1 | L | Approx 20% of symbol | Approx 7% |
2 | M | Approx 37% of symbol | Approx 15% |
3 | Q | Approx 55% of symbol | Approx 25% |
4 | H | Approx 65% of symbol | Approx 30% |
The size of the symbol can be specified by setting the
--vers
option (API option_2
) to the QR Code
version required (1-40). The size of symbol generated is shown in the
table below.
Input | Symbol Size | Input | Symbol Size | Input | Symbol Size | ||
---|---|---|---|---|---|---|---|
1 | 21 x 21 | 15 | 77 x 77 | 29 | 133 x 133 | ||
2 | 25 x 25 | 16 | 81 x 81 | 30 | 137 x 137 | ||
3 | 29 x 29 | 17 | 85 x 85 | 31 | 141 x 141 | ||
4 | 33 x 33 | 18 | 89 x 89 | 32 | 145 x 145 | ||
5 | 37 x 37 | 19 | 93 x 93 | 33 | 149 x 149 | ||
6 | 41 x 41 | 20 | 97 x 97 | 34 | 153 x 153 | ||
7 | 45 x 45 | 21 | 101 x 101 | 35 | 157 x 157 | ||
8 | 49 x 49 | 22 | 105 x 105 | 36 | 161 x 161 | ||
9 | 53 x 53 | 23 | 109 x 109 | 37 | 165 x 165 | ||
10 | 57 x 57 | 24 | 113 x 113 | 38 | 169 x 169 | ||
11 | 61 x 61 | 25 | 117 x 117 | 39 | 173 x 173 | ||
12 | 65 x 65 | 26 | 121 x 121 | 40 | 177 x 177 | ||
13 | 69 x 69 | 27 | 125 x 125 | ||||
14 | 73 x 73 | 28 | 129 x 129 |
The maximum capacity of a QR Code symbol (version 40) is 7089 numeric
digits, 4296 alphanumeric characters or 2953 bytes of data. QR Code
symbols can also be used to encode GS1 data. QR Code symbols can by
default encode either characters in the Latin-1 set or Kanji, Katakana
and ASCII characters which are members of the Shift JIS encoding scheme.
In addition QR Code supports other character sets using the ECI
mechanism. Input should usually be entered as UTF-8 with conversion to
Latin-1 or Shift JIS being carried out by Zint. A separate symbology ID
(BARCODE_HIBC_QR
) can be used to encode Health Industry
Barcode (HIBC) data.
Non-ASCII data density may be maximized by using the
--fullmultibyte
switch (API
option_3 = ZINT_FULL_MULTIBYTE
), but check that your
barcode reader supports this before using.
QR Code has eight different masks designed to minimize unwanted
patterns. The best mask to use is selected automatically by Zint but may
be manually specified by using the --mask
switch with
values 0-7, or in the API by setting
option_3 = (N + 1) << 8
where N is 0-7. To use with
ZINT_FULL_MULTIBYTE
set
= ZINT_FULL_MULTIBYTE | (N + 1) << 8 option_3
The --fast
option (API
input_mode |= FAST_MODE
) may be used when leaving Zint to
automatically select a mask to reduce the number of masks to try to four
(0, 2, 4, 7).
QR Code supports Structured Append of up to 16 symbols and a numeric
ID (parity), which can be set by using the --structapp
option (see 4.17 Structured Append)
(API structapp
). The parity ID ranges from 0 (default) to
255, and for full compliance should be set to the value obtained by
XOR
-ing together each byte of the complete data forming the
sequence. Currently this calculation must be done outside of Zint.
A miniature version of the QR Code symbol for short messages, Micro
QR Code symbols can encode either Latin-1 characters or Shift JIS
characters. Input should be entered as a UTF-8 stream with conversion to
Latin-1 or Shift JIS being carried out automatically by Zint. A
preferred symbol size can be selected by using the --vers
option (API option_2
), as shown in the table below. Note
that versions M1 and M2 have restrictions on what characters can be
encoded.
Input | Version | Symbol Size | Allowed Characters |
---|---|---|---|
1 | M1 | 11 x 11 | Numeric only |
2 | M2 | 13 x 13 | Numeric, uppercase letters, space, and the
characters "$%*+-./:" |
3 | M3 | 15 x 15 | Latin-1 and Shift JIS |
4 | M4 | 17 x 17 | Latin-1 and Shift JIS |
Except for version M1, which is always ECC level L, the amount of ECC
codewords can be adjusted using the --secure
option (API
option_1
); however ECC level H is not available for any
version, and ECC level Q is only available for version M4:
Input | ECC Level | Error Correction Capacity | Recovery Capacity | Available for Versions |
---|---|---|---|---|
1 | L | Approx 20% of symbol | Approx 7% | M1, M2, M3, M4 |
2 | M | Approx 37% of symbol | Approx 15% | M2, M3, M4 |
3 | Q | Approx 55% of symbol | Approx 25% | M4 |
The defaults for symbol size and ECC level depend on the input and whether either of them is specified.
For barcode readers that support it, non-ASCII data density may be
maximized by using the --fullmultibyte
switch (API
option_3 = ZINT_FULL_MULTIBYTE
).
Micro QR Code has four different masks designed to minimize unwanted
patterns. The best mask to use is selected automatically by Zint but may
be manually specified by using the --mask
switch with
values 0-3, or in the API by setting
option_3 = (N + 1) << 8
where N is 0-3. To use with
ZINT_FULL_MULTIBYTE
set
= ZINT_FULL_MULTIBYTE | (N + 1) << 8 option_3
A rectangular version of QR Code, rMQR supports encoding of GS1 data,
and either Latin-1 characters or Shift JIS characters, and other
encodings using the ECI mechanism. As with other symbologies data should
be entered as UTF-8 with conversion being handled by Zint. The amount of
ECC codewords can be adjusted using the --secure
option
(API option_1
), however only ECC levels M and H are valid
for this type of symbol.
Input | ECC Level | Error Correction Capacity | Recovery Capacity |
---|---|---|---|
2 | M | Approx 37% of symbol | Approx 15% |
4 | H | Approx 65% of symbol | Approx 30% |
The preferred symbol sizes can be selected using the
--vers
option (API option_2
) as shown in the
table below. Input values between 33 and 38 fix the height of the symbol
while allowing Zint to determine the minimum symbol width.
Input | Version | Symbol Size (HxW) | Input | Version | Symbol Size (HxW) | |
---|---|---|---|---|---|---|
1 | R7x43 | 7 x 43 | 20 | R13x77 | 13 x 77 | |
2 | R7x59 | 7 x 59 | 21 | R13x99 | 13 x 99 | |
3 | R7x77 | 7 x 77 | 22 | R13x139 | 13 x 139 | |
4 | R7x99 | 7 x 99 | 23 | R15x43 | 15 x 43 | |
5 | R7x139 | 7 x 139 | 24 | R15x59 | 15 x 59 | |
6 | R9x43 | 9 x 43 | 25 | R15x77 | 15 x 77 | |
7 | R9x59 | 9 x 59 | 26 | R15x99 | 15 x 99 | |
8 | R9x77 | 9 x 77 | 27 | R15x139 | 15 x 139 | |
9 | R9x99 | 9 x 99 | 28 | R17x43 | 17 x 43 | |
10 | R9x139 | 9 x 139 | 29 | R17x59 | 17 x 59 | |
11 | R11x27 | 11 x 27 | 30 | R17x77 | 17 x 77 | |
12 | R11x43 | 11 x 43 | 31 | R17x99 | 17 x 99 | |
13 | R11x59 | 11 x 59 | 32 | R17x139 | 17 x 139 | |
14 | R11x77 | 11 x 77 | 33 | R7xW | 7 x automatic width | |
15 | R11x99 | 11 x 99 | 34 | R9xW | 9 x automatic width | |
16 | R11x139 | 11 x 139 | 35 | R11xW | 11 x automatic width | |
17 | R13x27 | 13 x 27 | 36 | R13xW | 13 x automatic width | |
18 | R13x43 | 13 x 43 | 37 | R15xW | 15 x automatic width | |
19 | R13x59 | 13 x 59 | 38 | R17xW | 17 x automatic width |
For barcode readers that support it, non-ASCII data density may be
maximized by using the --fullmultibyte
switch or in the API
by setting option_3 = ZINT_FULL_MULTIBYTE
.
A variation of QR Code used by Združenje Bank Slovenije (Bank
Association of Slovenia). The size, error correction level and ECI are
set by Zint and do not need to be specified. UPNQR is unusual in that it
uses Latin-2 (ISO/IEC 8859-2 plus ASCII) formatted data. Zint will
accept UTF-8 data and convert it to Latin-2, or if your data is already
Latin-2 formatted use the --binary
switch (API
input_mode = DATA MODE
).
The following example creates a symbol from data saved as a Latin-2 file:
zint -o upnqr.png -b 143 --scale=3 --binary -i upn.txt
A mask may be manually specified or the --fast
option
used as with QRCODE.
Developed by UPS the MaxiCode symbology employs a grid of hexagons surrounding a bullseye finder pattern. This symbology is designed for the identification of parcels. MaxiCode symbols can be encoded in one of five modes. In modes 2 and 3 MaxiCode symbols are composed of two parts named the primary and secondary messages. The primary message consists of a Structured Carrier Message which includes various data about the package being sent and the secondary message usually consists of address data in a data structure. The format of the primary message required by Zint is given in the following table.
Characters | Meaning |
---|---|
1 - 9 | Postcode data which can consist of up to 9 digits (for mode 2) |
or up to 6 alphanumeric characters (for mode 3). Remaining | |
unused characters for mode 3 can be filled with the SPACE | |
character (ASCII 32) or omitted. | |
(adjust the following character positions according to postcode | |
length) | |
10 - 12 | Three-digit country code according to ISO 3166-1. |
13 - 15 | Three-digit service code. This depends on your parcel courier. |
The primary message can be set at the command prompt using the
--primary
switch (API primary
). The secondary
message uses the normal data entry method. For example:
zint -o test.eps -b 57 --primary="999999999840012" \
-d "Secondary Message Here"
When using the API the primary message must be placed in the
primary
string. The secondary is entered in the same way as
described in 5.2 Encoding and
Saving to File. When either of these modes is selected Zint will
analyse the primary message and select either mode 2 or mode 3 as
appropriate.
As a convenience the secondary message for modes 2 and 3 can be set
to be prefixed by the ISO/IEC 15434 Format "01"
(transportation) sequence "[)>\R01\Gvv"
, where
vv
is a 2-digit version, by using the --scmvv
switch (API option_2 = vv + 1
). For example to use the
common version "96"
(ASC MH10/SC 8):
zint -b 57 --primary="152382802840001" --scmvv=96 --esc -d \
"1Z00004951\GUPSN\G06X610\G159\G1234567\G1/1\G\GY\G1 MAIN ST\GNY\GNY\R\E"
will prefix "[)>\R01\G96"
to the secondary message.
(\R
, \G
and \E
are the escape
sequences for Record Separator, Group Separator and End of Transmission
respectively - see Table : Escape
Sequences.)
Modes 4 to 6 can be accessed using the --mode
switch
(API option_1
). Modes 4 to 6 do not have a primary message.
For example:
zint -o test.eps -b 57 --mode=4 -d "A MaxiCode Message in Mode 4"
Mode 6 is reserved for the maintenance of scanner hardware and should not be used to encode user data.
This symbology uses Latin-1 character encoding by default but also supports the ECI encoding mechanism. The maximum length of text which can be placed in a MaxiCode symbol depends on the type of characters used in the text.
Example maximum data lengths are given in the table below:
Mode | Maximum Data Length for Capital Letters | Maximum Data Length for Numeric Digits | Number of Error Correction Codewords |
---|---|---|---|
2* |
84 | 126 | 50 |
3* |
84 | 126 | 50 |
4 | 93 | 138 | 50 |
5 | 77 | 113 | 66 |
6 | 93 | 138 | 50 |
*
- secondary only
MaxiCode supports Structured Append of up to 8 symbols, which can be
set by using the --structapp
option (see 4.17 Structured Append) (API
structapp
). It does not support specifying an ID.
MaxiCode uses a different scaling than other symbols for raster output, see 4.9.3 MaxiCode Raster Scaling, and also for EMF vector output, when the scale is multiplied by 20 instead of 2.
Invented by Andrew Longacre at Welch Allyn Inc in 1995 the Aztec Code symbol is a matrix symbol with a distinctive bullseye finder pattern. Zint can generate Compact Aztec Code (sometimes called Small Aztec Code) as well as ‘full-range’ Aztec Code symbols and by default will automatically select symbol type and size dependent on the length of the data to be encoded. Error correction codewords will normally be generated to fill at least 23% of the symbol. Two options are available to change this behaviour:
The size of the symbol can be specified using the --vers
option (API option_2
) to a value between 1 and 36 according
to the following table. The symbols marked with an asterisk
(*
) in the table below are ‘compact’ symbols, meaning they
have a smaller bullseye pattern at the centre of the symbol.
Input | Symbol Size | Input | Symbol Size | Input | Symbol Size | ||
---|---|---|---|---|---|---|---|
1 | 15 x 15* |
13 | 53 x 53 | 25 | 105 x 105 | ||
2 | 19 x 19* |
14 | 57 x 57 | 26 | 109 x 109 | ||
3 | 23 x 23* |
15 | 61 x 61 | 27 | 113 x 113 | ||
4 | 27 x 27* |
16 | 67 x 67 | 28 | 117 x 117 | ||
5 | 19 x 19 | 17 | 71 x 71 | 29 | 121 x 121 | ||
6 | 23 x 23 | 18 | 75 x 75 | 30 | 125 x 125 | ||
7 | 27 x 27 | 19 | 79 x 79 | 31 | 131 x 131 | ||
8 | 31 x 31 | 20 | 83 x 83 | 32 | 135 x 135 | ||
9 | 37 x 37 | 21 | 87 x 87 | 33 | 139 x 139 | ||
10 | 41 x 41 | 22 | 91 x 91 | 34 | 143 x 143 | ||
11 | 45 x 45 | 23 | 95 x 95 | 35 | 147 x 147 | ||
12 | 49 x 49 | 24 | 101 x 101 | 36 | 151 x 151 |
Note that in symbols which have a specified size the amount of error correction is dependent on the length of the data input and Zint will allow error correction capacities as low as 3 codewords.
Alternatively the amount of error correction data can be specified by
setting the --secure
option (API option_1
) to
a value from the following table.
Mode | Error Correction Capacity |
---|---|
1 | >10% + 3 codewords |
2 | >23% + 3 codewords |
3 | >36% + 3 codewords |
4 | >50% + 3 codewords |
It is not possible to select both symbol size and error correction capacity for the same symbol. If both options are selected then the error correction capacity selection will be ignored.
Aztec Code supports ECI encoding and can encode up to a maximum
length of approximately 3823 numeric or 3067 alphabetic characters or
1914 bytes of data. A separate symbology ID
(BARCODE_HIBC_AZTEC
) can be used to encode Health Industry
Barcode (HIBC) data.
Aztec Code supports Structured Append of up to 26 symbols and an
optional alphanumeric ID of up to 32 characters, which can be set by
using the --structapp
option (see 4.17 Structured Append) (API
structapp
). The ID cannot contain spaces. If an ID is not
given, no ID is encoded.
A truncated version of compact Aztec Code for encoding whole integers between 0 and 255, as defined in ISO/IEC 24778 Annex A. Includes Reed-Solomon error correction. It does not support Structured Append.
A matrix symbology developed by Ted Williams in 1992 which encodes
data in a way similar to Data Matrix, Code One is able to encode the
Latin-1 character set or GS1 data, and also supports the ECI mechanism.
There are two types of Code One symbol - fixed-ratio symbols which are
roughly square (versions A through to H) and variable-width versions
(versions S and T). These can be selected by using --vers
(API option_2
) as shown in the table below:
Input | Version | Size (W x H) | Numeric Data Capacity | Alphanumeric Data Capacity |
---|---|---|---|---|
1 | A | 16 x 18 | 22 | 13 |
2 | B | 22 x 22 | 44 | 27 |
3 | C | 28 x 28 | 104 | 64 |
4 | D | 40 x 42 | 217 | 135 |
5 | E | 52 x 54 | 435 | 271 |
6 | F | 70 x 76 | 886 | 553 |
7 | G | 104 x 98 | 1755 | 1096 |
8 | H | 148 x 134 | 3550 | 2218 |
9 | S | width x 8 | 18 | N/A |
10 | T | width x 16 | 90 | 55 |
Version S symbols can only encode numeric data. The width of version S and version T symbols is determined by the length of the input data.
Code One supports Structured Append of up to 128 symbols, which can
be set by using the --structapp
option (see 4.17 Structured Append) (API
structapp
). It does not support specifying an ID.
Structured Append is not supported with GS1 data nor for Version S
symbols.
Grid Matrix groups modules in a chequerboard pattern, and by default supports the GB 2312 standard set, which includes Hanzi, ASCII and a small number of ISO/IEC 8859-1 characters. Input should be entered as UTF-8 with conversion to GB 2312 being carried out automatically by Zint. The symbology also supports the ECI mechanism. Support for GS1 data has not yet been implemented.
The size of the symbol and the error correction capacity can be
specified. If you specify both of these values then Zint will make a
‘best-fit’ attempt to satisfy both conditions. The symbol size can be
specified using the --vers
option (API
option_2
), and the error correction capacity can be
specified by using the --secure
option (API
option_1
), according to the following tables.
Input | Symbol Size | Input | Symbol Size | |
---|---|---|---|---|
1 | 18 x 18 | 8 | 102 x 102 | |
2 | 30 x 30 | 9 | 114 x 114 | |
3 | 42 x 42 | 10 | 126 x 126 | |
4 | 54 x 54 | 11 | 138 x 138 | |
5 | 66 x 66 | 12 | 150 x 150 | |
6 | 78 x 78 | 13 | 162 x 162 | |
7 | 90 x 90 |
Mode | Error Correction Capacity |
---|---|
1 | Approximately 10% |
2 | Approximately 20% |
3 | Approximately 30% |
4 | Approximately 40% |
5 | Approximately 50% |
Non-ASCII data density may be maximized by using the
--fullmultibyte
switch (API
option_3 = ZINT_FULL_MULTIBYTE
), but check that your
barcode reader supports this before using.
Grid Matrix supports Structured Append of up to 16 symbols and a
numeric ID (file signature), which can be set by using the
--structapp
option (see 4.17
Structured Append) (API structapp
). The ID ranges from
0 (default) to 255.
DotCode uses a grid of dots in a rectangular formation to encode
characters up to a maximum of approximately 450 characters (or 900
numeric digits). The symbology supports ECI encoding and GS1 data
encoding. By default Zint will produce a symbol which is approximately
square, however the width of the symbol can be adjusted by using the
--cols
option (API option_2
) (maximum 200).
Outputting DotCode to raster images (BMP, GIF, PCX, PNG, TIF) will
require setting the scale of the image to a larger value than the
default (e.g. approximately 10) for the dots to be plotted correctly.
Approximately 33% of the resulting symbol is comprised of error
correction codewords.
DotCode has two sets of 4 masks, designated 0-3 and 0’-3’, the second
"prime"
set being the same as the first with corners lit.
The best mask to use is selected automatically by Zint but may be
manually specified by using the --mask
switch with values
0-7, where 4-7 denote 0’-3’, or in the API by setting
option_3 = (N + 1) << 8
where N is 0-7.
DotCode supports Structured Append of up to 35 symbols, which can be
set by using the --structapp
option (see 4.17 Structured Append) (API
structapp
). It does not support specifying an ID.
Also known as Chinese Sensible Code, Han Xin is capable of encoding characters in either the Latin-1 character set or the GB 18030 character set (which is a UTF, i.e. includes all Unicode characters, optimized for Chinese characters) and is also able to support the ECI mechanism. Support for the encoding of GS1 data has not yet been implemented.
The size of the symbol can be specified using the --vers
option (API option_2
) to a value between 1 and 84 according
to the following table.
Input | Symbol Size | Input | Symbol Size | Input | Symbol Size | ||
---|---|---|---|---|---|---|---|
1 | 23 x 23 | 29 | 79 x 79 | 57 | 135 x 135 | ||
2 | 25 x 25 | 30 | 81 x 81 | 58 | 137 x 137 | ||
3 | 27 x 27 | 31 | 83 x 83 | 59 | 139 x 139 | ||
4 | 29 x 29 | 32 | 85 x 85 | 60 | 141 x 141 | ||
5 | 31 x 31 | 33 | 87 x 87 | 61 | 143 x 143 | ||
6 | 33 x 33 | 34 | 89 x 89 | 62 | 145 x 145 | ||
7 | 35 x 35 | 35 | 91 x 91 | 63 | 147 x 147 | ||
8 | 37 x 37 | 36 | 93 x 93 | 64 | 149 x 149 | ||
9 | 39 x 39 | 37 | 95 x 95 | 65 | 151 x 151 | ||
10 | 41 x 41 | 38 | 97 x 97 | 66 | 153 x 153 | ||
11 | 43 x 43 | 39 | 99 x 99 | 67 | 155 x 155 | ||
12 | 45 x 45 | 40 | 101 x 101 | 68 | 157 x 157 | ||
13 | 47 x 47 | 41 | 103 x 103 | 69 | 159 x 159 | ||
14 | 49 x 49 | 42 | 105 x 105 | 70 | 161 x 161 | ||
15 | 51 x 51 | 43 | 107 x 107 | 71 | 163 x 163 | ||
16 | 53 x 53 | 44 | 109 x 109 | 72 | 165 x 165 | ||
17 | 55 x 55 | 45 | 111 x 111 | 73 | 167 x 167 | ||
18 | 57 x 57 | 46 | 113 x 113 | 74 | 169 x 169 | ||
19 | 59 x 59 | 47 | 115 x 115 | 75 | 171 x 171 | ||
20 | 61 x 61 | 48 | 117 x 117 | 76 | 173 x 173 | ||
21 | 63 x 63 | 49 | 119 x 119 | 77 | 175 x 175 | ||
22 | 65 x 65 | 50 | 121 x 121 | 78 | 177 x 177 | ||
23 | 67 x 67 | 51 | 123 x 123 | 79 | 179 x 179 | ||
24 | 69 x 69 | 52 | 125 x 125 | 80 | 181 x 181 | ||
25 | 71 x 71 | 53 | 127 x 127 | 81 | 183 x 183 | ||
26 | 73 x 73 | 54 | 129 x 129 | 82 | 185 x 185 | ||
27 | 75 x 75 | 55 | 131 x 131 | 83 | 187 x 187 | ||
28 | 77 x 77 | 56 | 133 x 133 | 84 | 189 x 189 |
There are four levels of error correction capacity available for Han
Xin Code which can be set by using the --secure
option (API
option_1
) to a value from the following table.
Mode | Recovery Capacity |
---|---|
1 | Approx 8% |
2 | Approx 15% |
3 | Approx 23% |
4 | Approx 30% |
Non-ASCII data density may be maximized by using the
--fullmultibyte
switch (API
option_3 = ZINT_FULL_MULTIBYTE
), but check that your
barcode reader supports this before using.
Han Xin has four different masks designed to minimize unwanted
patterns. The best mask to use is selected automatically by Zint but may
be manually specified by using the --mask
switch with
values 0-3, or in the API by setting
option_3 = (N + 1) << 8
where N is 0-3. To use with
ZINT_FULL_MULTIBYTE
set
= ZINT_FULL_MULTIBYTE | (N + 1) << 8 option_3
This symbology uses a grid of coloured elements to encode data. ECI
and GS1 modes are supported. The amount of error correction can be set
using the --secure
option (API option_1
) to a
value as shown in the following table.
Value | EC Level | Amount of symbol holding error correction data |
---|---|---|
1 | EC0 | 0% - Error detection only |
2 | EC1 | Approx 5% |
3 | EC2 | Approx 9% - Default value |
4 | EC3 | Approx 17% |
5 | EC4 | Approx 25% |
6 | EC5 | Approx 33% |
Zint does not currently implement data compression by default, but this can be initiated through the API by setting
->option_3 = ULTRA_COMPRESSION; symbol
WARNING: Ultracode data compression is experimental and should not be used in a production environment.
Revision 2 of Ultracode (2021) which swops and inverts the DCCU and
DCCL tiles may be specified using --vers=2
(API
option_2 = 2
).
Ultracode supports Structured Append of up to 8 symbols and an
optional numeric ID (File Number), which can be set by using the
--structapp
option (see 4.17
Structured Append) (API structapp
). The ID ranges from
1 to 80088. If an ID is not given, no ID is encoded.
Used by the United States Postal Service (USPS), the FIM symbology is used to assist automated mail processing. There are only 5 valid symbols which can be generated using the characters A-E as shown in the table below.
Code Letter | Usage |
---|---|
A | Used for courtesy reply mail and metered reply mail with a |
pre-printed POSTNET symbol. | |
B | Used for business reply mail without a pre-printed zip code. |
C | Used for business reply mail with a pre-printed zip code. |
D | Used for Information Based Indicia (IBI) postage. |
E | Used for customized mail with a USPS Intelligent Mail barcode. |
Used for the recognition of page sequences in print-shops, the Flattermarken is not a true barcode symbol and requires precise knowledge of the position of the mark on the page. The Flattermarken system can encode numeric data up to a maximum of 128 digits and does not include a check digit.
Zint, libzint and Zint Barcode Studio are Copyright © 2023 Robin Stuart. All historical versions are distributed under the GNU General Public License version 3 or later. Versions 2.5 and later are released under a dual license: the encoding library is released under the BSD (3 clause) license whereas the GUI, Zint Barcode Studio, and the CLI are released under the GNU General Public License version 3 or later.
Telepen is a trademark of SB Electronic Systems Ltd.
QR Code is a registered trademark of Denso Wave Incorporated.
Mailmark is a registered trademark of Royal Mail Group Ltd.
Microsoft, Windows and the Windows logo are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.
Linux is the registered trademark of Linus Torvalds in the U.S. and other countries.
Mac and macOS are trademarks of Apple Inc., registered in the U.S. and other countries.
The Zint logo is derived from “SF Planetary Orbiter” font by ShyFoundary.
Zint.org.uk website design and hosting provided by Robert Elliott.
All of the code in Zint is developed using information in the public domain, usually freely available on the Internet. Some of the techniques used may be subject to patents and other intellectual property legislation. It is my belief that any patents involved in the technology underlying symbologies utilised by Zint are ‘unadopted’, that is the holder does not object to their methods being used.
Any methods patented or owned by third parties or trademarks or registered trademarks used within Zint or in this document are and remain the property of their respective owners and do not indicate endorsement or affiliation with those owners, companies or organisations.
The current stable version of Zint is 2.12.0, released on 12th December 2022.
See "ChangeLog"
in the project root directory for
information on all releases.
Below is a list of some of the sources used in rough chronological order:
Zint was developed to provide compliance with the following British and international standards:
A number of other specification documents have also been referenced, such as MIL-STD-1189 Rev. B (1989) (LOGMARS), USPS DMM 300 2006 (2011) (POSTNET, PLANET, FIM) and USPS-B-3200 (2015) (IMAIL). Those not named include postal and delivery company references in particular.
This section is intended as a quick reference to the character sets used by Zint. All symbologies use standard ASCII input as shown in section A.1, but some support extended characters as shown in the subsequent section A.2 Latin Alphabet No. 1 (ISO/IEC 8859-1).
The ubiquitous ASCII standard is well known to most computer users. It’s reproduced here for reference.
Hex | 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 |
---|---|---|---|---|---|---|---|---|
0 | NUL |
DLE |
SPACE |
0 |
@ |
P |
` |
p |
1 | SOH |
DC1 |
! |
1 |
A |
Q |
a |
q |
2 | STX |
DC2 |
" |
2 |
B |
R |
b |
r |
3 | ETX |
DC3 |
# |
3 |
C |
S |
c |
s |
4 | EOT |
DC4 |
$ |
4 |
D |
T |
d |
t |
5 | ENQ |
NAK |
% |
5 |
E |
U |
e |
u |
6 | ACK |
SYN |
& |
6 |
F |
V |
f |
v |
7 | BEL |
ETB |
' |
7 |
G |
W |
g |
w |
8 | BS |
CAN |
( |
8 |
H |
X |
h |
x |
9 | TAB |
EM |
) |
9 |
I |
Y |
i |
y |
A | LF |
SUB |
* |
: |
J |
Z |
j |
z |
B | VT |
ESC |
+ |
; |
K |
[ |
k |
{ |
C | FF |
FS |
, |
< |
L |
\ |
l |
| |
D | CR |
GS |
- |
= |
M |
] |
m |
} |
E | SO |
RS |
. |
> |
N |
^ |
n |
~ |
F | SI |
US |
/ |
? |
O |
_ |
o |
DEL |
ISO/IEC 8859-1 defines additional characters common in western European languages like French, German, Italian and Spanish. This extension is the default encoding of many barcodes (see Table : Default Character Sets) when a codepoint above hex 9F is encoded. Note that codepoints hex 80 to 9F are not defined.
Hex | 8 | 9 | A | B | C | D | E | F |
---|---|---|---|---|---|---|---|---|
0 | NBSP |
° |
À |
Ð |
à |
ð |
||
1 | ¡ |
± |
Á |
Ñ |
á |
ñ |
||
2 | ¢ |
² |
 |
Ò |
â |
ò |
||
3 | £ |
³ |
à |
Ó |
ã |
ó |
||
4 | ¤ |
´ |
Ä |
Ô |
ä |
ô |
||
5 | ¥ |
μ |
Å |
Õ |
å |
õ |
||
6 | ¦ |
¶ |
Æ |
Ö |
æ |
ö |
||
7 | § |
· |
Ç |
× |
ç |
÷ |
||
8 | ¨ |
¸ |
È |
Ø |
è |
ø |
||
9 | © |
¹ |
É |
Ù |
é |
ù |
||
A | ª |
º |
Ê |
Ú |
ê |
ú |
||
B | « |
» |
Ë |
Û |
ë |
û |
||
C | ¬ |
¼ |
Ì |
Ü |
ì |
ü |
||
D | SHY |
½ |
Í |
Ý |
í |
ý |
||
E | ® |
¾ |
Î |
Þ |
î |
þ |
||
F | ¯ |
¿ |
Ï |
ß |
ï |
ÿ |
Used internally by Zint Barcode Studio to display the preview, the Qt
Backend QZint
renders a barcode by drawing the vector
representation (see 5.5
Buffering Symbols in Memory (vector)) provided by the Zint library
libzint
.
The main class is Zint::QZint
, which has getter/setter
properties that correspond to the zint_symbol
structure
(see 5.6 Setting Options), and a main
method render()
which takes a Qt QPainter
to
paint with, and a QRectF
rectangular area specifying where
to paint into:
/* Encode and display barcode in `paintRect` using `painter`.
Note: legacy argument `mode` is not used */
void render(QPainter& painter, const QRectF& paintRect,
= IgnoreAspectRatio); AspectRatioMode mode
render()
will emit one of two Qt signals -
encoded
on successful encoding and drawing, or
errored
on failure. The client can connect and act
appropriately, for instance:
connect(qzint, SIGNAL(encoded()), SLOT(on_encoded()));
connect(qzint, SIGNAL(errored()), SLOT(on_errored()));
where qzint
is an instance of Zint::QZint
and on_encoded()
and on_error()
are Qt slot
methods provided by the caller. On error, the error value and message
can be retrieved by the methods getError()
and
lastError()
respectively.
The other main method is save_to_file()
:
/* Encode and print barcode to file `filename`.
Only sets `getError()` on error, not on warning */
bool save_to_file(const QString& filename); // `ZBarcode_Print()`
which takes a filename
to output to. It too will emit an
errored
signal on failure, returning false
(but nothing on success, which just returns true
). Note
that rotation is achieved through the setter method
setRotateAngleValue()
(as opposed to the
rotate_angle
argument used by
ZBarcode_Print()
).
Various other methods are available, for instance methods for testing
symbology capabilities, and utility methods such as
defaultXdim()
and getAsCLI()
.
For full details, see "backend_qt/qzint.h"
.
A Tcl binding is available in the "backend_tcl
”
sub-directory. To make on Unix:
cd backend_tcl
autoconf
./configure
make
sudo make install
For Windows, a Visual Studio 6.0 project file is available at
"backend_tcl\zint_tcl.dsp"
. This can also be opened (and
converted) by more modern Visual Studio versions, though some fixing up
of the project configuration will likely be required.
Once built and installed, invoke the Tcl/Tk CLI
"wish"
:
wish
and ignoring the Tk window click back to the command prompt
"%"
and type:
require package zint
zint help
which will show the usage message, with options very similiar to the
Zint CLI. (One notable difference is that boolean options such as
-bold
take a 1
or 0
as an
argument.)
A demonstration Tcl/Tk program which is also useful in itself is
available at "backend_tcl/demo/demo.tcl"
. To run type:
wish demo/demo.tcl
which will display the following window.
You can select the symbology, enter the data to encode, and set
options (which are the same as those given in the usage message). A
raster preview of the configured barcode is displayed once the
"Generate"
button is pressed.
zint
- encode data as a barcode image
zint
[-h
|
--help
]zint
[options]zint takes input data from the command line or a file to encode in a barcode which is then output to an image file.
Input data is UTF-8, unless --binary
is specified.
Human Readable Text (HRT) is displayed by default for those barcodes
that support HRT, unless --notext
is specified.
The output image file (specified with -o
|
--output
) may be in one of these formats: Windows Bitmap
(BMP
), Enhanced Metafile Format (EMF
),
Encapsulated PostScript (EPS
), Graphics Interchange Format
(GIF
), ZSoft Paintbrush (PCX
), Portable
Network Format (PNG
), Scalable Vector Graphic
(SVG
), or Tagged Image File Format (TIF
).
-h
, --help
Print usage information summarizing command line options.
-b TYPE
, --barcode=TYPE
Set the barcode symbology that will be used to encode the data.
TYPE is the number or name of the barcode symbology. If not
given, the symbology defaults to 20 (Code 128). To see what types are
available, use the -t
| --types
option. Type
names are case-insensitive, and non-alphanumerics are ignored.
--addongap=INTEGER
For EAN/UPC symbologies, set the gap between the main data and the add-on. INTEGER is in integral multiples of the X-dimension. The maximum gap that can be set is 12. The minimum is 7, except for UPC-A, when the minimum is 9.
--batch
Treat each line of an input file specified with -i
|
--input
as a separate data set and produce a barcode image
for each one. The barcode images are outputted by default to numbered
filenames starting with “00001.png”, “00002.png” etc., which can be
changed by using the -o
| --output
option.
--bg=COLOUR
Specify a background (paper) colour where COLOUR is in
hexadecimal RRGGBB
or RRGGBBAA
format or in
decimal C,M,Y,K
percentages format.
--binary
Treat input data as raw 8-bit binary data instead of the default UTF-8. Automatic code page translation to an ECI page is disabled, and no validation of the data’s character encoding takes place.
--bind
Add horizontal boundary bars (also known as bearer bars) to the
symbol. The width of the boundary bars is specified by the
--border
option. --bind
can also be used to
add row separator bars to symbols stacked with multiple -d
| --data
inputs, in which case the width of the separator
bars is specified with the --separator
option.
--bindtop
Add a horizontal boundary bar to the top of the symbol. The width of
the boundary bar is specified by the --border
option.
--bold
Use bold text for the Human Readable Text (HRT).
--border=INTEGER
Set the width of boundary bars (--bind
or
--bindtop
) or box borders (--box
), where
INTEGER is in integral multiples of the X-dimension. The
default is zero.
--box
Add a box around the symbol. The width of the borders is specified by
the --border
option.
--cmyk
Use the CMYK colour space when outputting to Encapsulated PostScript (EPS) or TIF files.
--cols=INTEGER
Set the number of data columns in the symbol to INTEGER. Affects Codablock-F, DotCode, GS1 DataBar Expanded Stacked (DBAR_EXPSTK), MicroPDF417 and PDF417 symbols.
--compliantheight
Warn if the height specified by the --height
option is
not compliant with the barcode’s specification, or if
--height
is not given, default to the height specified by
the specification (if any).
-d
, --data=DATA
Specify the input DATA to encode. The --esc
option may be used to enter non-printing characters using escape
sequences. The DATA should be UTF-8, unless the
--binary
option is given, in which case it can be
anything.
--direct
Send output to stdout, which in most cases should be re-directed to a
pipe or a file. Use --filetype
to specify output
format.
--dmiso144
For Data Matrix symbols, use the standard ISO/IEC codeword placement
for 144 x 144 (--vers=24
) sized symbols, instead of the
default “de facto” placement (which rotates the placement of ECC
codewords).
--dmre
For Data Matrix symbols, allow Data Matrix Rectangular Extended
(DMRE) sizes when considering automatic sizes. See also
--square
.
--dotsize=NUMBER
Set the radius of the dots in dotty mode (--dotty
).
NUMBER is in X-dimensions, and may be floating-point. The
default is 0.8.
--dotty
Use dots instead of squares for matrix symbols. DotCode is always in dotty mode.
--dump
Dump a hexadecimal representation of the symbol’s encodation to
stdout. The same representation may be outputted to a file by using a
.txt
extension with -o
| --output
or by specifying --filetype=txt
.
-e
, --ecinos
Display the table of ECIs (Extended Channel Interpretations).
--eci=INTEGER
Set the ECI code for the input data to INTEGER. See
-e
| --ecinos
for a list of the ECIs
available. ECIs are supported by Aztec Code, Code One, Data Matrix,
DotCode, Grid Matrix, Han Xin Code, MaxiCode, MicroPDF417, PDF417, QR
Code, rMQR and Ultracode.
--embedfont
For vector output, embed the font in the file for portability. Currently only available for SVG output.
--esc
Process escape characters in the input data. The escape sequences are:
\0 (0x00) NUL Null character
\E (0x04) EOT End of Transmission
\a (0x07) BEL Bell
\b (0x08) BS Backspace
\t (0x09) HT Horizontal Tab
\n (0x0A) LF Line Feed
\v (0x0B) VT Vertical Tab
\f (0x0C) FF Form Feed
\r (0x0D) CR Carriage Return
\e (0x1B) ESC Escape
\G (0x1D) GS Group Separator
\R (0x1E) RS Record Separator
\\ (0x5C) \ Backslash
\dNNN (NNN) Any 8-bit character where NNN is
decimal (000-255)
\oNNN (0oNNN) Any 8-bit character where NNN is
octal (000-377)
\xNN (0xNN) Any 8-bit character where NN is
hexadecimal (00-FF)
\uNNNN (U+NNNN) Any 16-bit Unicode BMP character
where NNNN is hexadecimal
\UNNNNNN (U+NNNNNN) Any 21-bit Unicode character
where NNNNNN is hexadecimal
--extraesc
Process the special escape sequences \^A
,
\^B
and \^C
that allow manual switching of
Code Sets (Code 128 only). The sequence \^^
can be used to
encode data that contains special escape sequences.
--fast
Use faster if less optimal encodation or other shortcuts (affects Data Matrix, MicroPDF417, PDF417, QRCODE & UPNQR only).
--fg=COLOUR
Specify a foreground (ink) colour where COLOUR is in
hexadecimal RRGGBB
or RRGGBBAA
format or in
decimal C,M,Y,K
percentages format.
--filetype=TYPE
Set the output file type to TYPE, which is one of
BMP
, EMF
, EPS
, GIF
,
PCX
, PNG
, SVG
, TIF
,
TXT
.
--fullmultibyte
Use the multibyte modes of Grid Matrix, Han Xin and QR Code for non-ASCII data.
--gs1
Treat input as GS1 compatible data. Application Identifiers (AIs)
should be placed in square brackets "[]"
(but see
--gs1parens
).
--gs1nocheck
Do not check the validity of GS1 data.
--gs1parens
Process parentheses "()"
as GS1 AI delimiters, rather
than square brackets "[]"
. The input data must not
otherwise contain parentheses.
--gssep
For Data Matrix in GS1 mode, use GS
(0x1D) as the GS1
data separator instead of FNC1
.
--guarddescent=NUMBER
For EAN/UPC symbols, set the height the guard bars descend below the main bars, where NUMBER is in X-dimensions. NUMBER may be floating-point.
--guardwhitespace
For EAN/UPC symbols, add quiet zone indicators "<"
and/or ">"
to HRT where applicable.
--height=NUMBER
Set the height of the symbol in X-dimensions. NUMBER may be floating-point.
--heightperrow
Treat height as per-row. Affects Codablock-F, Code 16K, Code 49, GS1 DataBar Expanded Stacked (DBAR_EXPSTK), MicroPDF417 and PDF417.
-i
, --input=FILE
Read the input data from FILE. Specify a single hyphen
(-
) for FILE to read from stdin.
--init
Create a Reader Initialisation (Programming) symbol.
--mask=INTEGER
Set the masking pattern to use for DotCode, Han Xin or QR Code to INTEGER, overriding the automatic selection.
--mirror
Use the batch data to determine the filename in batch mode
(--batch
). The -o
| --output
option can be used to specify an output directory (any filename will be
ignored).
--mode=INTEGER
For MaxiCode and GS1 Composite symbols, set the encoding mode to INTEGER.
For MaxiCode (SCM is Structured Carrier Message, with 3 fields: postcode, 3-digit ISO 3166-1 country code, 3-digit service code):
2 SCM with 9-digit numeric postcode
3 SCM with 6-character alphanumeric postcode
4 Enhanced ECC for the primary part of the message
5 Enhanced ECC for all of the message
6 Reader Initialisation (Programming)
For GS1 Composite symbols (names end in _CC
,
i.e. EANX_CC, GS1_128_CC, DBAR_OMN_CC etc.):
1 CC-A
2 CC-B
3 CC-C (GS1_128_CC only)
--nobackground
Remove the background colour (EMF, EPS, GIF, PNG, SVG and TIF only).
--noquietzones
Disable any quiet zones for symbols that define them by default.
--notext
Remove the Human Readable Text (HRT).
-o
, --output=FILE
Send the output to FILE. When not in batch mode, the default
is “out.png” (or “out.gif” if zint built without PNG support). When in
batch mode (--batch
), special characters can be used to
format the output filenames:
~ Insert a number or 0
# Insert a number or space
@ Insert a number or * (+ on Windows)
Any other Insert literally
--primary=STRING
For MaxiCode, set the content of the primary message. For GS1 Composite symbols, set the content of the linear symbol.
--quietzones
Add compliant quiet zones for symbols that specify them. This is in
addition to any whitespace specified by -w
|
--whitesp
or --vwhitesp
.
-r
, --reverse
Reverse the foreground and background colours (white on black). Known as “reflectance reversal” or “reversed reflectance”.
--rotate=INTEGER
Rotate the symbol by INTEGER degrees, where INTEGER can be 0, 90, 270 or 360.
--rows=INTEGER
Set the number of rows for Codablock-F or PDF417 to INTEGER. It will also set the minimum number of rows for Code 16K or Code 49, and the maximum number of rows for GS1 DataBar Expanded Stacked (DBAR_EXPSTK).
--scale=NUMBER
Adjust the size of the X-dimension. NUMBER may be floating-point, and is multiplied by 2 (except for MaxiCode) before being applied. The default scale is 1.
For MaxiCode, the scale is multiplied by 10 for raster output, by 40 for EMF output, and by 2 otherwise.
Increments of 0.5 (half-integers) are recommended for non-MaxiCode raster output (BMP, GIF, PCX, PNG and TIF).
See also --scalexdimdp
below.
--scalexdimdp=X[,R]
Scale the image according to X-dimension X and resolution R, where X is in mm and R is in dpmm (dots per mm). X and R may be floating-point. R is optional and defaults to 12 dpmm (approximately 300 dpi). X may be zero in which case a symbology-specific default is used.
The scaling takes into account the output filetype, and deals with
all the details mentioned above. Units may be specified for X
by appending “in” (inch) or “mm”, and for R by appending “dpi”
(dots per inch) or “dpmm” -
e.g. --scalexdimdp=0.013in,300dpi
.
--scmvv=INTEGER
For MaxiCode, prefix the Structured Carrier Message (SCM) with
"[)>\R01\Gvv"
, where vv
is a 2-digit
INTEGER.
--secure=INTEGER
Set the error correction level (ECC) to INTEGER. The meaning is specific to the following matrix symbols (all except PDF417 are approximate):
Aztec Code 1 to 4 (10%, 23%, 36%, 50%)
Grid Matrix 1 to 5 (10% to 50%)
Han Xin 1 to 4 (8%, 15%, 23%, 30%)
Micro QR 1 to 3 (7%, 15%, 25%) (L, M, Q)
PDF417 0 to 8 (2^(INTEGER + 1) codewords)
QR Code 1 to 4 (7%, 15%, 25%, 30%) (L, M, Q, H)
rMQR 2 or 4 (15% or 30%) (M or H)
Ultracode 1 to 6 (0%, 5%, 9%, 17%, 25%, 33%)
--segN=ECI,DATA
Set the ECI & DATA content for segment N, where
N is 1 to 9. -d
| --data
must still be given,
and counts as segment 0, its ECI given by --eci
. Segments
must be consecutive.
--separator=INTEGER
Set the height of row separator bars for stacked symbologies, where INTEGER is in integral multiples of the X-dimension. The default is zero.
--small
Use small text for Human Readable Text (HRT).
--square
For Data Matrix symbols, exclude rectangular sizes when considering
automatic sizes. See also --dmre
.
--structapp=I,C[,ID]
Set Structured Append info, where I is the 1-based index, C is the total number of symbols in the sequence, and ID, which is optional, is the identifier that all symbols in the sequence share. Structured Append is supported by Aztec Code, Code One, Data Matrix, DotCode, Grid Matrix, MaxiCode, MicroPDF417, PDF417, QR Code and Ultracode.
-t
, --types
Display the table of barcode types (symbologies). The numbers or
names can be used with -b
| --barcode
.
--textgap=NUMBER
Adjust the gap between the barcode and the Human Readable Text (HRT). NUMBER is in X-dimensions, and may be floating-point. Maximum is 10 and minimum is -5. The default is 1.
--vers=INTEGER
Set the symbol version (size, check digits, other options) to INTEGER. The meaning is symbol-specific.
For most matrix symbols, it specifies size:
Aztec Code 1 to 36 (1 to 4 compact)
1 15x15 13 53x53 25 105x105
2 19x19 14 57x57 26 109x109
3 23x23 15 61x61 27 113x113
4 27x27 16 67x67 28 117x117
5 19x19 17 71x71 29 121x121
6 23x23 18 75x75 30 125x125
7 27x27 19 79x79 31 131x131
8 31x31 20 83x83 32 135x135
9 37x37 21 87x87 33 139x139
10 41x41 22 91x91 34 143x143
11 45x45 23 95x95 35 147x147
12 49x49 24 101x101 36 151x151
Code One 1 to 10 (9 and 10 variable width) (WxH)
1 16x18 6 70x76
2 22x22 7 104x98
3 28x28 8 148x134
4 40x42 9 Wx8
5 52x54 10 Wx16
Data Matrix 1 to 48 (31 to 48 DMRE) (HxW)
1 10x10 17 72x72 33 8x80
2 12x12 18 80x80 34 8x96
3 14x14 19 88x88 35 8x120
4 16x16 20 96x96 36 8x144
5 18x18 21 104x104 37 12x64
6 20x20 22 120x120 38 12x88
7 22x22 23 132x132 39 16x64
8 24x24 24 144x144 40 20x36
9 26x26 25 8x18 41 20x44
10 32x32 26 8x32 42 20x64
11 36x36 28 12x26 43 22x48
12 40x40 28 12x36 44 24x48
13 44x44 29 16x36 45 24x64
14 48x48 30 16x48 46 26x40
15 52x52 31 8x48 47 26x48
16 64x64 32 8x64 48 26x64
Grid Matrix 1 to 13
1 18x18 6 78x78 11 138x138
2 30x30 7 90x90 12 150x150
3 42x42 8 102x102 13 162x162
4 54x54 9 114x114
5 66x66 10 126x126
Han Xin 1 to 84
1 23x23 29 79x79 57 135x135
2 25x25 30 81x81 58 137x137
3 27x27 31 83x83 59 139x139
4 29x29 32 85x85 60 141x141
5 31x31 33 87x87 61 143x143
6 33x33 34 89x89 62 145x145
7 35x35 35 91x91 63 147x147
8 37x37 36 93x93 64 149x149
9 39x39 37 95x95 65 151x151
10 41x41 38 97x97 66 153x153
11 43x43 39 99x99 67 155x155
12 45x45 40 101x101 68 157x157
13 47x47 41 103x103 69 159x159
14 49x49 42 105x105 70 161x161
15 51x51 43 107x107 71 163x163
16 53x53 44 109x109 72 165x165
17 55x55 45 111x111 73 167x167
18 57x57 46 113x113 74 169x169
19 59x59 47 115x115 75 171x171
20 61x61 48 117x117 76 173x173
21 63x63 49 119x119 77 175x175
22 65x65 50 121x121 78 177x177
23 67x67 51 123x123 79 179x179
24 69x69 52 125x125 80 181x181
25 71x71 53 127x127 81 183x183
26 73x73 54 129x129 82 185x185
27 75x75 55 131x131 83 187x187
28 77x77 56 133x133 84 189x189
Micro QR 1 to 4 (M1, M2, M3, M4)
1 11x11 3 15x15
2 13x13 4 17x17
QR Code 1 to 40
1 21x21 15 77x77 29 133x133
2 25x25 16 81x81 30 137x137
3 29x29 17 85x85 31 141x141
4 33x33 18 89x89 32 145x145
5 37x37 19 93x93 33 149x149
6 41x41 20 97x97 34 153x153
7 45x45 21 101x101 35 157x157
8 49x49 22 105x105 36 161x161
9 53x53 23 109x109 37 165x165
10 57x57 24 113x113 38 169x169
11 61x61 25 117x117 39 173x173
12 65x65 26 121x121 40 177x177
13 69x69 27 125x125
14 73x73 28 129x129
rMQR 1 to 38 (33 to 38 automatic width) (HxW)
1 7x43 14 11x77 27 15x139
2 7x59 15 11x99 28 17x43
3 7x77 16 11x139 29 17x59
4 7x99 17 13x27 30 17x77
5 7x139 18 13x43 31 17x99
6 9x43 19 13x59 32 17x139
7 9x59 20 13x77 33 7xW
8 9x77 21 13x99 34 9xW
9 9x99 22 13x139 35 11xW
10 9x139 23 15x43 36 13xW
11 11x27 24 15x59 37 15xW
12 11x43 25 15x77 38 17xW
13 11x59 26 15x99
For a number of linear symbols, it specifies check character options (“hide” or “hidden” means don’t show in HRT, “visible” means do display in HRT):
C25IATA 1 or 2 (add visible or hidden check digit)
C25IND ditto
C25INTER ditto
C25LOGIC ditto
C25STANDARD ditto
Codabar 1 or 2 (add hidden or visible check digit)
Code 11 0 to 2 (2 visible check digits to none)
0 (default 2 visible check digits)
1 (1 visible check digit)
2 (no check digits)
Code 39 1 or 2 (add visible or hidden check digit)
Code 93 1 (hide the default check characters)
EXCODE39 1 or 2 (add visible or hidden check digit)
LOGMARS 1 or 2 (add visible or hidden check digit)
MSI Plessey 0 to 6 (none to various visible options)
1, 2 (mod-10, mod-10 + mod-10)
3, 4 (mod-11 IBM, mod-11 IBM + mod-10)
5, 6 (mod-11 NCR, mod-11 NCR + mod-10)
+10 (hide)
For a few other symbologies, it specifies other characteristics:
Channel Code 3 to 8 (no. of channels)
DAFT 50 to 900 (permille tracker ratio)
DPD 1 (relabel)
PZN 1 (PZN7 instead of default PZN8)
Ultracode 2 (revision 2)
VIN 1 (add international prefix)
-v
, --version
Display zint version.
--vwhitesp=INTEGER
Set the height of vertical whitespace above and below the barcode, where INTEGER is in integral multiples of the X-dimension.
-w
, --whitesp=INTEGER
Set the width of horizontal whitespace either side of the barcode, where INTEGER is in integral multiples of the X-dimension.
--werror
Convert all warnings into errors.
0
-h
|
--help
, -e
| --ecinos
,
-t
| --types
, -v
|
--version
).
1
ZINT_WARN_HRT_TRUNCATED
)
2
ZINT_WARN_INVALID_OPTION
)
3
ZINT_WARN_USES_ECI
)
4
ZINT_WARN_NONCOMPLIANT
)
5
ZINT_ERROR_TOO_LONG
)
6
ZINT_ERROR_INVALID_DATA
)
7
ZINT_ERROR_INVALID_CHECK
)
8
ZINT_ERROR_INVALID_OPTION
)
9
ZINT_ERROR_ENCODING_PROBLEM
)
10
ZINT_ERROR_FILE_ACCESS
)
11
ZINT_ERROR_MEMORY
)
12
ZINT_ERROR_FILE_WRITE
)
13
--werror
given
(ZINT_ERROR_USES_ECI
)
14
--werror
given
(ZINT_ERROR_NONCOMPLIANT
)
15
--werror
given
(ZINT_ERROR_HRT_TRUNCATED
)
Create “out.png” (or “out.gif” if zint built without PNG support) in the current directory, as a Code 128 symbol.
zint -d 'This Text'
Create “qr.svg” in the current directory, as a QR Code symbol.
zint -b QRCode -d 'This Text' -o 'qr.svg'
Use batch mode to read from an input file “ean13nos.txt” containing 13-digit GTINs, to create a series of EAN-13 barcodes, formatting the output filenames to “ean001.gif”, “ean002.gif” etc. using the special character “~”.
zint -b EANX --batch -i 'ean13nos.txt' -o 'ean~~~.gif'
Please send bug reports to https://sourceforge.net/p/zint/tickets/.
Full documention for zint
(and the API
libzint
and the GUI zint-qt
) is available
from
https://zint.org.uk/manual/
and at
https://sourceforge.net/p/zint/docs/manual.txt
Zint is designed to be compliant with a number of international standards, including:
ISO/IEC 24778:2008, ANSI/AIM BC12-1998, EN 798:1996, AIM ISS-X-24 (1995), ISO/IEC 15417:2007, EN 12323:2005, ISO/IEC 16388:2007, ANSI/AIM BC6-2000, ANSI/AIM BC5-1995, AIM USS Code One (1994), ISO/IEC 16022:2006, ISO/IEC 21471:2019, ISO/IEC 15420:2009, AIMD014 (v 1.63) (2008), ISO/IEC 24723:2010, ISO/IEC 24724:2011, ISO/IEC 20830:2021, ISO/IEC 16390:2007, ISO/IEC 16023:2000, ISO/IEC 24728:2006, ISO/IEC 15438:2015, ISO/IEC 18004:2015, ISO/IEC 23941:2022, AIM ITS/04-023 (2022)
Copyright © 2023 Robin Stuart. Released under GNU GPL 3.0 or later.
Robin Stuart robin@zint.org.uk